Performance of Conventional and Innovative Single U-Tube Pipe Configuration in Vertical Ground Heat Exchanger (VGHE)

被引:2
|
作者
Eswiasi, Adel [1 ]
Mukhopadhyaya, Phalguni [2 ]
机构
[1] Univ Victoria, Mech Engn, Victoria, BC V8W 2Y2, Canada
[2] Univ Victoria, Civil Engn, Victoria, BC V8W 2Y2, Canada
关键词
vertical ground heat exchanger; external fin; thermal response test; effective ground thermal conductivity; THERMAL RESPONSE TEST; GROUTING MATERIALS; BOREHOLES;
D O I
10.3390/su13116384
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A ground source heat pump system (GSHP) with a ground heat exchanger (GHE) is a renewable and green technology used for heating and cooling residential and commercial buildings. An innovative U-Tube pipe configuration is suggested to enhance the heat transfer rate in the vertical ground heat exchanger (VGHE). Laboratory experiments are conducted to compare the thermal efficiency of VGHEs with two different pipe configurations: (1) an innovative U-Tube pipe configuration (single U-Tube with two outer fins) and (2) a single U-Tube. The results show that the difference between the inlet and outlet temperatures for the innovative U-Tube pipe configuration was 0.7 degrees C after 60 h, while it was 0.4 degrees C for the single U-Tube after the same amount of time. The borehole thermal resistance for the innovative U-Tube pipe configuration was 0.680 m center dot K/W, which is 29.22% lower than that of the single U-Tube. The heat exchange rate in the innovative U-Tube pipe configuration is increased by 57.95% compared to the conventional single U-Tube. Measured ground temperatures indicate that compared to single U-Tube pipe configuration, the innovative U-Tube pipe configuration has superior heat transfer performance. Based on the experimental results presented in this paper, it was concluded that increasing the surface area significantly by introducing external fins to the U-Tube enhances the heat transfer rate, resulting in increased thermal efficiency of the VGHE.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Thermal performance of the vertical ground heat exchanger with a novel elliptical single U-tube
    Jahanbin, Aminhossein
    [J]. GEOTHERMICS, 2020, 86
  • [2] New Correlations for Thermal Resistances of Vertical Single U-Tube Ground Heat Exchanger
    Liao, Quan
    Zhou, Chao
    Cui, Wenzhi
    Jen, T.C.
    [J]. Journal of Thermal Science and Engineering Applications, 2012, 4 (03)
  • [3] Performance analysis of a solar-assisted ground source heat pump with a single vertical U-tube ground heat exchanger
    Adebayo, Philip
    Shor, Roman
    Mohamad, Abdulmajeed
    Wemhöner, Carsten
    Mwesigye, Aggrey
    [J]. Applied Thermal Engineering, 2024, 257
  • [4] Thermal performance of a single U-tube ground heat exchanger: A parametric study
    Mousavi Ajarostaghi, Seyed Soheil
    Javadi, Hossein
    Mousavi, Seyed Sina
    Poncet, Sebastien
    Pourfallah, Mohsen
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2021, 28 (11) : 3580 - 3598
  • [5] Vertical U-tube Ground Heat Exchanger design method research
    Wang, P. Y.
    Tian, H. F.
    Cao, W. W.
    [J]. CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 974 - 978
  • [6] Experimental study of the effect of backfills on the thermal performance of a vertical U-tube ground heat exchanger
    Yang, W.B.
    Wang, S.S.
    Liu, G.Y.
    Zhu, J.L.
    [J]. 7th International Symposium on Heating, Ventilating and Air Conditioning - Proceedings of ISHVAC 2011, 2011, 4 : 1341 - 1346
  • [7] EXPERIMENTAL STUDY OF THE EFFECT OF BACKFILLS ON THE THERMAL PERFORMANCE OF A VERTICAL U-TUBE GROUND HEAT EXCHANGER
    Yang, W. B.
    Wang, S. S.
    Liu, G. Y.
    Zhu, J. L.
    [J]. 7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 1341 - 1346
  • [8] Performance evaluation of a vertical U-tube ground heat exchanger using a numerical simulation approach
    Hu, Pingfang
    Yu, Zhongyi
    Lei, Fei
    Zhu, Na
    Sun, Qiming
    Yuan, Xudong
    [J]. APPLIED ENERGY TECHNOLOGY, PTS 1 AND 2, 2013, 724-725 : 909 - +
  • [9] Numerical simulation and experimental validation of a vertical U-tube ground heat exchanger
    Gao, Yike
    Gao, Yan
    Yu, Yong
    Lin, Xinxing
    [J]. ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 709 - +
  • [10] Numerical Analysis of the Factors Influencing a Vertical U-Tube Ground Heat Exchanger
    Chen, Shangyuan
    Mao, Jinfeng
    Han, Xu
    Li, Chaofeng
    Liu, Liyao
    [J]. SUSTAINABILITY, 2016, 8 (09):