Performance analysis of a solar-assisted ground source heat pump with a single vertical U-tube ground heat exchanger

被引:0
|
作者
Adebayo, Philip [1 ]
Shor, Roman [2 ]
Mohamad, Abdulmajeed [1 ]
Wemhöner, Carsten [3 ]
Mwesigye, Aggrey [1 ]
机构
[1] Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary,AB, Canada
[2] Harold Vance, Department of Petroleum Engineering, Texas A&M University, College Station,TX, United States
[3] Department of Building Services Engineering, IET Institute for Energy Technology, Eastern Switzerland University of Applied Sciences, Oberseestrasse 10, Rapperswil,8640, Switzerland
关键词
All Open Access; Hybrid Gold;
D O I
10.1016/j.applthermaleng.2024.124452
中图分类号
学科分类号
摘要
36
引用
收藏
相关论文
共 50 条
  • [1] Numerical Simulation and Analysis for the U-tube Heat Exchanger of Ground Source Heat Pump
    Chang Zhen
    Guo Min
    [J]. 2013 32ND CHINESE CONTROL CONFERENCE (CCC), 2013, : 8713 - 8717
  • [2] Numerical Analysis of the Heat Transfer Characteristics of Vertical U-Tube Ground Heat Exchanger Used in Ground Coupled Heat Pump
    Yang, Weibo
    Shi, Mingheng
    Chen, Zhenqian
    [J]. 6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1857 - 1864
  • [3] Thermal performance of the vertical ground heat exchanger with a novel elliptical single U-tube
    Jahanbin, Aminhossein
    [J]. GEOTHERMICS, 2020, 86
  • [4] Experimental and Simulant Study on Vertical U-Tube Underground Heat Exchanger in Ground-Source Heat Pump
    Gao, Zhen
    Ma, Jinwei
    Yu, Xiaochun
    Zhang, Yu
    Hu, Ning
    Wang, Yanping
    [J]. PROCEEDINGS OF THE 2015 4TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND ENVIRONMENTAL ENGINEERING, 2016, 53 : 636 - 641
  • [5] Heating system with vapour compressor heat pump and vertical U-tube ground heat exchanger
    Hanuszkiewicz-Drapala, Malgorzata
    Skladzien, Jan
    [J]. ARCHIVES OF THERMODYNAMICS, 2010, 31 (04) : 93 - 110
  • [6] Simulation study on the thermal performance of vertical U-tube heat exchangers for ground source heat pump system
    Pu, Liang
    Qi, Di
    Li, Kang
    Tan, Hongbo
    Li, Yanzhong
    [J]. APPLIED THERMAL ENGINEERING, 2015, 79 : 202 - 213
  • [7] Numerical Analysis of the Factors Influencing a Vertical U-Tube Ground Heat Exchanger
    Chen, Shangyuan
    Mao, Jinfeng
    Han, Xu
    Li, Chaofeng
    Liu, Liyao
    [J]. SUSTAINABILITY, 2016, 8 (09):
  • [8] Thermal performance of a single U-tube ground heat exchanger: A parametric study
    Mousavi Ajarostaghi, Seyed Soheil
    Javadi, Hossein
    Mousavi, Seyed Sina
    Poncet, Sebastien
    Pourfallah, Mohsen
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2021, 28 (11) : 3580 - 3598
  • [9] New Correlations for Thermal Resistances of Vertical Single U-Tube Ground Heat Exchanger
    Liao, Quan
    Zhou, Chao
    Cui, Wenzhi
    Jen, T.C.
    [J]. Journal of Thermal Science and Engineering Applications, 2012, 4 (03)
  • [10] Vertical U-tube Ground Heat Exchanger design method research
    Wang, P. Y.
    Tian, H. F.
    Cao, W. W.
    [J]. CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 974 - 978