Evaluation of noninvasive oscillometric blood pressure monitoring in anesthetized boid snakes

被引:9
|
作者
Chinnadurai, Sathya K. [1 ,2 ]
Wrenn, Amy [3 ]
DeVoe, Ryan S. [2 ]
机构
[1] N Carolina State Univ, Coll Vet Med, Dept Clin Sci, Raleigh, NC 27606 USA
[2] N Carolina State Univ, Coll Vet Med, Environm Med Consortium, Raleigh, NC 27606 USA
[3] Chatham Anim Hosp, Cary, NC 27513 USA
关键词
DOGS; CATS; ANESTHESIA; REPTILES; MANAGEMENT; MORTALITY;
D O I
10.2460/javma.234.5.625
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To determine the accuracy of a noninvasive oscillometric monitor in the measurement of arterial blood pressure in anesthetized boid snakes. Design-Evaluation study. Animals-4 boa constrictors (Boa constrictor), 2 carpet pythons (Morelia spilota), and 2 reticulated pythons (Python reticulatus). Procedures-After induction of anesthesia with isoflurane, each snake was instrumented with an arterial catheter connected to a pressure transducer and oscilloscope to obtain invasive measurements of systolic (SAP), diastolic (DAP), and mean (MAP) arterial blood pressure as well as a pressure waveform. A cuff connected to an oscillometric device was placed on the tail immediately distal to the vent for noninvasive measurements. Heart rate, respiratory rate, and invasive and noninvasive measurements of SAP DAP and MAP were obtained every 5 minutes for 45 minutes. Delivered isoflurane concentration was increased in 15-minute increments to induce hypotension. Repeatability of each device and fixed and proportional biases between devices were calculated. Results-Throughout most of the measured ranges of blood pressures, the oscillometric unit overestimated the SAP and underestimated the DAP and MAP compared with respective direct measurements. When the invasively determined SAP was > 100 mm Hg, the oscillometric unit underestimated all 3 variables. Fixed bias was significant for SAP and DAP and proportional bias was significant for SAP and MAP Conclusions and Clinical Relevance-When using an oscillometric blood pressure monitor on anesthetized boid snakes, veterinarians can potentially monitor changes in blood pressure, although the displayed readings may underestimate DAP and MAP and overestimate SAP Indirect measurements of blood pressure made with the oscillometric device cannot substitute for direct measurements. (J Am Vet Med Assoc 2009;234:625-630)
引用
收藏
页码:625 / 630
页数:6
相关论文
共 50 条
  • [21] Evaluation of the tongue for oscillometric measurement of arterial pressure in anesthetized Beagle dogs
    Kim, Dalhae
    Kim, Hyunseok
    Shin, Donghwi
    Kim, Jiyoung
    Lee, Inhyung
    Son, Won-gyun
    VETERINARY ANAESTHESIA AND ANALGESIA, 2022, 49 (02) : 149 - 155
  • [22] BLOOD-PRESSURE MONITORING - AUTOMATED OSCILLOMETRIC DEVICES
    RAMSEY, M
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (01): : 56 - 67
  • [23] NONINVASIVE BLOOD-PRESSURE MEASUREMENT IN NEONATES AND INFANTS WITH THE OSCILLOMETRIC METHOD
    PAPADOPOULOS, G
    ANAESTHESIST, 1994, 43 (07): : 441 - 446
  • [24] Validation of oscillometric noninvasive blood pressure measurement devices using simulators
    Amoore, John N.
    Lemesre, Yann
    Murray, Ian C.
    Vacher, Emilie
    Mieke, Stephan
    King, Susan T.
    Smith, Fiona E.
    Murray, Alan
    BLOOD PRESSURE MONITORING, 2007, 12 (04) : 251 - 253
  • [25] THE ACCURACY OF CENTRAL BLOOD PRESSURE OBTAINED BY OSCILLOMETRIC NONINVASIVE METHOD IN CHILDREN
    Shiraishi, M.
    Murakami, T.
    JOURNAL OF HYPERTENSION, 2018, 36 : E72 - E73
  • [26] CLINICAL-EVALUATION OF THE CALIBRATION OF NONINVASIVE CONTINUOUS BLOOD-PRESSURE MEASUREMENT DEVICES BY MEANS OF OSCILLOMETRIC BLOOD-PRESSURE MEASUREMENTS
    DEJONG, JR
    ROS, HH
    DELANGE, JJ
    BRITISH JOURNAL OF ANAESTHESIA, 1993, 70 : 8 - 8
  • [27] Indirect oscillometric and direct blood pressure measurements in anesthetized and conscious neonatal foals
    Nout, YS
    Corley, KTT
    Donaldson, LL
    Furr, MO
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2002, 12 (02): : 75 - 80
  • [28] Evaluation of the Accuracy and Precision of the GE Dash 4000 Oscillometric Monitor for Blood Pressure Measurement in Anesthetized Female Dogs
    Barbieri Ferronatto, Joao Victor
    Monteiro, Eduardo Raposo
    Correia, Barbara Silva
    Queiroga, Luciana Branquinho
    Herrera Becerra, Jose Ricardo
    ACTA SCIENTIAE VETERINARIAE, 2018, 46
  • [29] Intraoperative Blood Pressure Misclassification Due to Inaccuracy of Noninvasive Oscillometric Cuff-Measured Blood Pressure
    Kim, Danny Sungsoo
    Kwon, Sohee
    Bovik, Alan C.
    Markey, Mia K.
    Giovannucci, Edward L.
    Cannesson, Maxime
    HYPERTENSION, 2025, 82 (02) : e1 - e3
  • [30] The impact of arm circumference on noninvasive oscillometric blood pressure referenced with intra-aortic blood pressure
    Qing Shangguan
    Wu, Yanqing
    Xu, Jinsong
    Su, Hai
    Li, Juxiang
    Hong, Kui
    Cheng, Xiaoshu
    BLOOD PRESSURE MONITORING, 2015, 20 (06) : 316 - 319