BLOOD-PRESSURE MONITORING - AUTOMATED OSCILLOMETRIC DEVICES

被引:89
|
作者
RAMSEY, M
机构
[1] From Critikon, Inc, Tampa, 33631-3800, FL
来源
JOURNAL OF CLINICAL MONITORING | 1991年 / 7卷 / 01期
关键词
MONITORING; BLOOD PRESSURE; MEASUREMENT TECHNIQUES; EQUIPMENT; AUTOMATED OSCILLOMETRIC DEVICES;
D O I
10.1007/BF01617900
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
An understanding of the principles of blood pressure measurement with automated oscillometric devices (e.g., Dinamap) allows a user to realize the purpose and level of accuracy for which the equipment is designed. Good technique calls for various actions: (1) using a cuff of proper size (too large a cuff will generally work acceptably, but too small a cuff will yield erroneously high readings); (2) squeezing all of the residual air out of the cuff before applying it to the arm or leg; (3) wrapping the cuff snugly around the arm or leg; (4) instructing the patient to refrain from talking or moving and letting nothing press against the cuff during measurement; (5) keeping the cuff and heart at the same horizontal level. (6) When instrument malfunction is suspected, first checking the status of the patient (not the status of the instrument) to be sure that a clinical emergency is not causing the suspected "malfunction"; (7) repeating a reading several times when it is suspicious and, if necessary, modifying the measurement conditions by using, for example, different limbs or different cuffs until the question is resolved; and (8) remembering that a leak in the cuff, hoses, or connection can cause an unexpected malfunction.
引用
收藏
页码:56 / 67
页数:12
相关论文
共 50 条
  • [1] OPTIMAL SITES FOR FOREHEAD OSCILLOMETRIC BLOOD-PRESSURE MONITORING
    LEE, TK
    SILVA, FH
    EGBERT, TP
    WESTENSKOW, DR
    [J]. JOURNAL OF CLINICAL MONITORING, 1995, 11 (05): : 298 - 304
  • [2] A NEW AUTOMATED VOLUME-OSCILLOMETRIC DEVICE FOR MONITORING AMBULATORY BLOOD-PRESSURE IN THE FINGER IN MAN
    IMAI, Y
    NIHEI, M
    ABE, K
    SASAKI, S
    MIURA, Y
    YUMITA, S
    SEKINO, H
    YAMAKOSHI, K
    YOSHINAGA, K
    [J]. JOURNAL OF HYPERTENSION, 1986, 4 : S662 - S664
  • [3] EVALUATING AUTOMATED BLOOD-PRESSURE DEVICES
    SMALL, CF
    MCEWEN, JA
    COX, NB
    JOHNSON, DL
    [J]. LANCET, 1981, 2 (8250): : 805 - 805
  • [4] AUTOMATED AMBULATORY BLOOD-PRESSURE MONITORING
    WHITE, LJ
    [J]. ANNALS OF INTERNAL MEDICINE, 1986, 104 (02) : 275 - 278
  • [5] DEVICES FOR MONITORING BLOOD-PRESSURE AT HOME
    不详
    [J]. MEDICAL LETTER ON DRUGS AND THERAPEUTICS, 1977, 19 (13): : 55 - 56
  • [6] A simulator for oscillometric blood-pressure signals to test automated noninvasive sphygmomanometers
    Riedel, W.
    Mieke, S.
    Seemann, R.
    Ittermann, B.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (02):
  • [8] ELECTRONIC DEVICES FOR THE SELF-MEASUREMENT OF BLOOD-PRESSURE - COMPARISON OF OSCILLOMETRIC AND KOROTKOW DEVICES
    KRIBBEN, A
    WEBER, F
    ANLAUF, M
    CLAUS, M
    HIRCHE, H
    SIMONIDES, R
    PHILIPP, T
    [J]. NIEREN-UND HOCHDRUCKKRANKHEITEN, 1992, 21 (08) : 351 - 357
  • [9] AUTOMATIC BLOOD-PRESSURE MONITORING WITH AN OSCILLOMETRIC MEASURING SYSTEM - ACCURACY AND ACCEPTABILITY
    KOLLING, K
    KRAUS, F
    HAASE, HU
    REDL, A
    [J]. NIEREN-UND HOCHDRUCKKRANKHEITEN, 1992, 21 (10) : 448 - 452
  • [10] Personalization of the Oscillometric Blood-Pressure Measurement
    Nagy, P.
    Jobbagy, A.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 2, 2019, 68 (02): : 885 - 888