OPTIMAL SITES FOR FOREHEAD OSCILLOMETRIC BLOOD-PRESSURE MONITORING

被引:4
|
作者
LEE, TK [1 ]
SILVA, FH [1 ]
EGBERT, TP [1 ]
WESTENSKOW, DR [1 ]
机构
[1] UNIV UTAH,DEPT ANESTHESIOL,SALT LAKE CITY,UT 84132
来源
JOURNAL OF CLINICAL MONITORING | 1995年 / 11卷 / 05期
关键词
MONITORING; BLOOD PRESSURE; MEASUREMENT TECHNIQUES; OSCILLOMETRY; ARTERY; SUPERFICIAL TEMPORAL; SUPRAORBITAL;
D O I
10.1007/BF01616987
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective. Blood pressure is usually measured noninvasively with a cuff on the arm or the leg. Circumstances exist, however, when an alternative site for blood pressure measurement is desirable. This study is designed to identify a location on the forehead where blood pressure can be reliably measured noninvasively. Methods, We mapped the superficial temporal artery and/or the supraorbital artery in 65 volunteers and found a rectangular area where an adhesive pressure pad could be placed over each artery. Oscillometric signals were recorded from four different locations over the forehead in 19 of the 65 volunteers to compare the amplitude of the signal and mean blood pressure between locations. Results. The course of the supraorbital artery is quite consistent. It passed through a 2.5- x 1-cm rectangular area on the forehead in all volunteers in which it was mapped. The medial border of the rectangle is 0.5-cm medial and 1-cm above the medial corner of the left eyebrow. The course of the superficial temporal artery differed remarkably from person to person. We could not find an area of reasonable size to cover the artery in all volunteers. Mean blood pressures were the same in all forehead locations. The signal was the weakest on the center of the forehead and strongest directly over the superficial temporal artery. Conclusions. Our results show that the supraorbital artery, an end-artery of the internal carotid artery, which emerges through the supraorbital foramen and crosses the forehead near the center, is the preferred site to monitor blood pressure noninvasively on the forehead with an adhesive pressure bladder.
引用
收藏
页码:298 / 304
页数:7
相关论文
共 50 条
  • [1] BLOOD-PRESSURE MONITORING - AUTOMATED OSCILLOMETRIC DEVICES
    RAMSEY, M
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (01): : 56 - 67
  • [2] AUTOMATIC BLOOD-PRESSURE MONITORING WITH AN OSCILLOMETRIC MEASURING SYSTEM - ACCURACY AND ACCEPTABILITY
    KOLLING, K
    KRAUS, F
    HAASE, HU
    REDL, A
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 1992, 21 (10) : 448 - 452
  • [3] Personalization of the Oscillometric Blood-Pressure Measurement
    Nagy, P.
    Jobbagy, A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 2, 2019, 68 (02): : 885 - 888
  • [4] VALIDITY OF NEWBORN OSCILLOMETRIC BLOOD-PRESSURE
    LOW, JA
    PANAGIOTOPOULOS, C
    SMITH, JT
    TANG, W
    DERRICK, EJ
    CLINICAL AND INVESTIGATIVE MEDICINE-MEDECINE CLINIQUE ET EXPERIMENTALE, 1995, 18 (03): : 163 - 167
  • [5] RELIABILITY OF AUTOMATIC OSCILLOMETRIC MONITORING OF BLOOD-PRESSURE - INFLUENCE OF HYPOTENSION AND ARRHYTHMIAS
    CARAMELLA, JP
    DESMONTS, JM
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1986, 79 (12): : 1794 - 1799
  • [6] COMPARATIVE ACCURACIES OF A FINGER BLOOD-PRESSURE MONITOR AND AN OSCILLOMETRIC BLOOD-PRESSURE MONITOR
    EPSTEIN, RH
    HUFFNAGLE, S
    BARTKOWSKI, RR
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (02): : 161 - 167
  • [7] OSCILLOMETRIC FINGER BLOOD-PRESSURE VERSUS BRACHIAL AUSCULTATIVE BLOOD-PRESSURE RECORDING
    IYRIBOZ, Y
    JOURNAL OF FAMILY PRACTICE, 1990, 31 (04): : 376 - 380
  • [8] INTRAOPERATIVE OSCILLOMETRIC ARTERIAL BLOOD-PRESSURE MONITORING USING NONSTANDARD CUFF LOCATIONS
    ZORNOW, MH
    SCHUBERT, A
    TODD, MM
    ANESTHESIOLOGY, 1986, 65 (3A) : A135 - A135
  • [9] ACCURACY OF OSCILLOMETRIC BLOOD-PRESSURE MEASUREMENTS IN PREECLAMPSIA
    SHENNAN, A
    DESWIET, M
    HALLIGAN, A
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1995, 172 (04) : 1325 - 1325
  • [10] COMPARISONS OF AUSCULTATORY AND OSCILLOMETRIC BLOOD-PRESSURE MEASUREMENTS
    PARK, MK
    WEAVER, MG
    LEE, DH
    PEDIATRIC RESEARCH, 1989, 25 (04) : A104 - A104