OPTIMAL SITES FOR FOREHEAD OSCILLOMETRIC BLOOD-PRESSURE MONITORING

被引:4
|
作者
LEE, TK [1 ]
SILVA, FH [1 ]
EGBERT, TP [1 ]
WESTENSKOW, DR [1 ]
机构
[1] UNIV UTAH,DEPT ANESTHESIOL,SALT LAKE CITY,UT 84132
来源
JOURNAL OF CLINICAL MONITORING | 1995年 / 11卷 / 05期
关键词
MONITORING; BLOOD PRESSURE; MEASUREMENT TECHNIQUES; OSCILLOMETRY; ARTERY; SUPERFICIAL TEMPORAL; SUPRAORBITAL;
D O I
10.1007/BF01616987
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective. Blood pressure is usually measured noninvasively with a cuff on the arm or the leg. Circumstances exist, however, when an alternative site for blood pressure measurement is desirable. This study is designed to identify a location on the forehead where blood pressure can be reliably measured noninvasively. Methods, We mapped the superficial temporal artery and/or the supraorbital artery in 65 volunteers and found a rectangular area where an adhesive pressure pad could be placed over each artery. Oscillometric signals were recorded from four different locations over the forehead in 19 of the 65 volunteers to compare the amplitude of the signal and mean blood pressure between locations. Results. The course of the supraorbital artery is quite consistent. It passed through a 2.5- x 1-cm rectangular area on the forehead in all volunteers in which it was mapped. The medial border of the rectangle is 0.5-cm medial and 1-cm above the medial corner of the left eyebrow. The course of the superficial temporal artery differed remarkably from person to person. We could not find an area of reasonable size to cover the artery in all volunteers. Mean blood pressures were the same in all forehead locations. The signal was the weakest on the center of the forehead and strongest directly over the superficial temporal artery. Conclusions. Our results show that the supraorbital artery, an end-artery of the internal carotid artery, which emerges through the supraorbital foramen and crosses the forehead near the center, is the preferred site to monitor blood pressure noninvasively on the forehead with an adhesive pressure bladder.
引用
收藏
页码:298 / 304
页数:7
相关论文
共 50 条
  • [21] BLOOD-PRESSURE MEASUREMENT USING OSCILLOMETRIC FINGER CUFFS
    OBRIEN, E
    ATKINS, N
    ANAESTHESIA, 1995, 50 (08) : 743 - 744
  • [22] EVALUATION OF AN AUTOMATIC OSCILLOMETRIC METHOD OF MEASURING BLOOD-PRESSURE
    FRANCOUAL, M
    HIMMICH, H
    FISCHLER, M
    DAVID, R
    DESSERTENNE, J
    ROHAN, J
    LOIRAT, P
    AGRESSOLOGIE, 1980, 21 : 157 - 161
  • [23] AMBULATORY BLOOD-PRESSURE MONITORING AND BLOOD-PRESSURE REACTIVITY
    HARSHFIELD, GA
    PICKERING, TG
    PSYCHOPHYSIOLOGY, 1986, 23 (04) : 422 - 423
  • [24] MONITORING BLOOD-PRESSURE
    不详
    LANCET, 1979, 2 (8155): : 1279 - 1280
  • [25] BLOOD-PRESSURE MONITORING
    CARROLL, GC
    CRITICAL CARE CLINICS, 1988, 4 (03) : 411 - 434
  • [26] A NEW AUTOMATED VOLUME-OSCILLOMETRIC DEVICE FOR MONITORING AMBULATORY BLOOD-PRESSURE IN THE FINGER IN MAN
    IMAI, Y
    NIHEI, M
    ABE, K
    SASAKI, S
    MIURA, Y
    YUMITA, S
    SEKINO, H
    YAMAKOSHI, K
    YOSHINAGA, K
    JOURNAL OF HYPERTENSION, 1986, 4 : S662 - S664
  • [27] VALUE OF AMBULATORY BLOOD-PRESSURE MONITORING FOR DETERMINING OPTIMAL BLOOD-PRESSURE VALUES IN PATIENTS WITH DIABETES-MELLITUS
    MAYAUDON, H
    CROZES, P
    MOUTEL, G
    CHANUDET, X
    CHAU, NP
    LARROQUE, P
    BAUDUCEAU, B
    SEMAINE DES HOPITAUX, 1994, 70 (21-22): : 615 - 619
  • [28] DIFFERENCES IN BLOOD-PRESSURE LEVELS OBTAINED BY AUSCULTATORY AND OSCILLOMETRIC METHODS
    WEAVER, MG
    PARK, MK
    LEE, DH
    AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1990, 144 (08): : 911 - 914
  • [29] ACCURACY OF OSCILLOMETRIC BLOOD-PRESSURE MEASUREMENT IN CRITICALLY ILL NEONATES
    GEVERS, M
    VANGENDERINGEN, HR
    LAFEBER, HN
    HACK, WW
    PEDIATRIC RESEARCH, 1994, 36 (01) : A15 - A15
  • [30] NONINVASIVE BLOOD-PRESSURE MEASUREMENT IN NEONATES AND INFANTS WITH THE OSCILLOMETRIC METHOD
    PAPADOPOULOS, G
    ANAESTHESIST, 1994, 43 (07): : 441 - 446