Evaluation of noninvasive oscillometric blood pressure monitoring in anesthetized boid snakes

被引:9
|
作者
Chinnadurai, Sathya K. [1 ,2 ]
Wrenn, Amy [3 ]
DeVoe, Ryan S. [2 ]
机构
[1] N Carolina State Univ, Coll Vet Med, Dept Clin Sci, Raleigh, NC 27606 USA
[2] N Carolina State Univ, Coll Vet Med, Environm Med Consortium, Raleigh, NC 27606 USA
[3] Chatham Anim Hosp, Cary, NC 27513 USA
关键词
DOGS; CATS; ANESTHESIA; REPTILES; MANAGEMENT; MORTALITY;
D O I
10.2460/javma.234.5.625
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To determine the accuracy of a noninvasive oscillometric monitor in the measurement of arterial blood pressure in anesthetized boid snakes. Design-Evaluation study. Animals-4 boa constrictors (Boa constrictor), 2 carpet pythons (Morelia spilota), and 2 reticulated pythons (Python reticulatus). Procedures-After induction of anesthesia with isoflurane, each snake was instrumented with an arterial catheter connected to a pressure transducer and oscilloscope to obtain invasive measurements of systolic (SAP), diastolic (DAP), and mean (MAP) arterial blood pressure as well as a pressure waveform. A cuff connected to an oscillometric device was placed on the tail immediately distal to the vent for noninvasive measurements. Heart rate, respiratory rate, and invasive and noninvasive measurements of SAP DAP and MAP were obtained every 5 minutes for 45 minutes. Delivered isoflurane concentration was increased in 15-minute increments to induce hypotension. Repeatability of each device and fixed and proportional biases between devices were calculated. Results-Throughout most of the measured ranges of blood pressures, the oscillometric unit overestimated the SAP and underestimated the DAP and MAP compared with respective direct measurements. When the invasively determined SAP was > 100 mm Hg, the oscillometric unit underestimated all 3 variables. Fixed bias was significant for SAP and DAP and proportional bias was significant for SAP and MAP Conclusions and Clinical Relevance-When using an oscillometric blood pressure monitor on anesthetized boid snakes, veterinarians can potentially monitor changes in blood pressure, although the displayed readings may underestimate DAP and MAP and overestimate SAP Indirect measurements of blood pressure made with the oscillometric device cannot substitute for direct measurements. (J Am Vet Med Assoc 2009;234:625-630)
引用
收藏
页码:625 / 630
页数:6
相关论文
共 50 条
  • [41] Impact of Atrial Fibrillation on the Accuracy of Oscillometric Blood Pressure Monitoring
    Pagonas, Nikolaos
    Schmidt, Sven
    Eysel, Joerg
    Compton, Friederike
    Hoffmann, Clemens
    Seibert, Felix
    Hilpert, Justus
    Tschoepe, Carsten
    Zidek, Walter
    Westhoff, Timm H.
    HYPERTENSION, 2013, 62 (03) : 579 - 584
  • [42] Arterial blood pressure monitoring in anesthetized animals
    Wagner, AE
    Brodbelt, DC
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 1997, 210 (09): : 1279 - 1285
  • [43] A simulator for oscillometric blood-pressure signals to test automated noninvasive sphygmomanometers
    Riedel, W.
    Mieke, S.
    Seemann, R.
    Ittermann, B.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (02):
  • [44] Influence of noninvasive central blood pressure devices for afterload monitoring with aortic velocity-pressure Loop in anesthetized patients
    Leve, Charlotte
    Hong, Alex
    Millasseau, Sandrine
    Joachim, Jona
    Touchard, Cyril
    Mateo, Joaquim
    Serrano, Jose
    Mebazaa, Alexandre
    Gayat, Etienne
    Vallee, Fabrice
    BLOOD PRESSURE MONITORING, 2020, 25 (04) : 184 - 194
  • [45] NONINVASIVE BLOOD-PRESSURE MONITORING FROM THE SUPRAORBITAL ARTERY USING AN ARTIFICIAL NEURAL-NETWORK OSCILLOMETRIC ALGORITHM
    NARUS, S
    EGBERT, T
    LEE, TK
    LU, J
    WESTENSKOW, D
    JOURNAL OF CLINICAL MONITORING, 1995, 11 (05): : 289 - 297
  • [46] A comparative study of invasive and oscillometric methods of arterial blood pressure measurement in the anesthetized rabbit
    Ypsilantis, P
    Didilis, VN
    Politou, M
    Bougioukas, I
    Bougioukas, G
    Simopoulos, C
    RESEARCH IN VETERINARY SCIENCE, 2005, 78 (03) : 269 - 275
  • [47] Comparison of two species-specific oscillometric blood pressure monitors with direct blood pressure measurement in anesthetized cats
    Cerejo, Sofia A.
    Teixeira-Neto, Francisco J.
    Garofalo, Natache A.
    Rodrigues, Jessica C.
    Celeita-Rodriguez, Nathalia
    Lagos-Carvajal, Angie P.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2017, 27 (04) : 409 - 418
  • [48] Comparison of the indirect oscillometric and direct arterial methods for blood pressure measurements in anesthetized dogs
    Meurs, KM
    Miller, MW
    Slater, MR
    JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 1996, 32 (06) : 471 - 475
  • [49] Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized sheep, goats, and cattle
    Aarnes, Turi K.
    Hubbell, John A. E.
    Lerche, Phillip
    Bednarski, Richard M.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2014, 41 (02) : 174 - 185
  • [50] Evaluation of oscillometric and vascular access port arterial blood pressure measurement techniques versus implanted telemetry in anesthetized cats
    Zwijnenberg, Raphael J.
    del Rio, Carlos L.
    Cobb, Rami M.
    Ueyama, Yukie
    Muir, William W.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2011, 72 (08) : 1015 - 1021