3D Monte Carlo dosimetry of intraoperative electron radiation therapy (IOERT)

被引:11
|
作者
Alhamada, Husein [1 ,2 ]
Simon, Stephane [1 ,2 ]
Philippson, Catherine [2 ]
Vandekerkhove, Christophe [2 ]
Jourani, Younes [2 ]
Pauly, Nicolas [1 ]
VanGestel, Dirk [2 ]
Reynaert, Nick [1 ,2 ]
机构
[1] Univ Libre Bruxelles, Ecole Polytech, Nucl Metrol, Brussels, Belgium
[2] Inst Jules Bordet, Radiotherapy Dept, Brussels, Belgium
关键词
DOSE CALCULATIONS; RADIOTHERAPY; IORT; DISTRIBUTIONS; APPLICATOR; PHOTON;
D O I
10.1016/j.ejmp.2018.12.037
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This paper studies the feasibility of using Monte Carlo (MC) for treatment planning of intraoperative electron radiation therapy (IOERT) procedure to get 3D dose by using patient's CT images. Methods: The IOERT treatment planning was performed using the following successive steps: I) The Mobetron 1000 degrees machine was modelled with the EGSnrc MC codes. II) The MC model was validated with measurements of percentage depth doses and profiles for three energies (12, 9, 6) MeV. III) CT images were imported as DICOM files. IV) Contouring of the planning target volume (PTV) and the organs at risk was done by the radiation oncologist. V) The medical physicist with the radiation oncologist, had chosen the same parameters of IOERT procedures like energy, applicator (type, size) and using or not bolus. VI) Finally, dose calculation and analysis of 3D maps was carried out. Results: The tuning process of the MC model provides good results, as the maximum value of the root mean square deviation (RMSD) was less than 3% between the MC simulated PDDs and the measured PDDs. The contouring and dose analysis review were easy to conduct for the classical treatment planning system. The radiation oncologist had many tools for dose analysis such as DVH and color wash for all the slides. Summation of the 3D dose of IOERT with other radiotherapy plans is possible and helpful for total dose estimation. Archiving and documentation is as good as treatment planning system (TPS). Conclusions: The method displayed in this paper provides a step forward for IOERT Dosimetry and allows to obtain accurate dosimetry of treated volumes.
引用
收藏
页码:207 / 214
页数:8
相关论文
共 50 条
  • [31] Monte Carlo simulation and film dosimetry for electron therapy in vicinity of a titanium mesh
    Jabbari, Keyvan
    Rostampour, Masoumeh
    Roayaei, Mahnaz
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (04): : 67 - 79
  • [32] 3D POLYMER GEL DOSIMETRY FOR QUALITY ASSURANCE IN RADIATION THERAPY
    Ceberg, Sofie
    Adliene, Diana
    Mattsson, Soren
    MEDICAL PHYSICS IN THE BALTIC STATES, 2017, : 30 - 35
  • [33] New 3D Silicon detectors for dosimetry in Microbeam Radiation Therapy
    Lerch, M. L. F.
    Dipuglia, A.
    Cameron, M.
    Fournier, P.
    Davis, J.
    Petasecca, M.
    Cornelius, I.
    Perevertaylo, V.
    Rosenfeld, A. B.
    MICRO-MINI & NANO-DOSIMETRY & INNOVATIVE TECHNOLOGIES IN RADIATION THERAPY (MMND&ITRO2016), 2017, 777
  • [34] A method to model 4D organs for Monte Carlo radiation dosimetry
    Shi, CY
    Xu, XG
    MEDICAL PHYSICS, 2005, 32 (06) : 1920 - 1920
  • [35] Monte Carlo calculation for Intra-Operative Radiotherapy (IOERT) with electron beams
    De Brouwer, T.
    Vandekerkhove, C.
    Simon, S.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S855 - S856
  • [36] Implementation of pencil beam redefinition algorithm (PBRA) for intraoperative electron radiation therapy (IOERT) treatment planning
    Tavallaie, Mina
    Tabrizi, Sanaz Hariri
    Heidarloo, Nematollah
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 104 : 32 - 42
  • [37] PREOPERATIVE RADIATION AND INTRAOPERATIVE ELECTRON RADIOTHERAPY (IOERT) OR BRACHYTHERAPY FOR EXTREMITY SARCOMA
    Ashman, J.
    Callister, M.
    Beauchamp, C.
    Schwartz, A.
    Fitch, T.
    Gunderson, L.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S8 - S9
  • [38] Monte Carlo investigation of breast intraoperative radiation therapy with metal attenuator plates
    Martignano, A.
    Menegotti, L.
    Valentini, A.
    MEDICAL PHYSICS, 2007, 34 (12) : 4578 - 4584
  • [39] THE ROLE OF MONTE-CARLO SIMULATION OF ELECTRON-TRANSPORT IN RADIATION-DOSIMETRY
    ROGERS, DWO
    APPLIED RADIATION AND ISOTOPES, 1991, 42 (10) : 965 - 974
  • [40] POSTPLANNING OF A THREE-DIMENSIONAL DOSE DISTRIBUTION FOR INTRAOPERATIVE ELECTRON RADIATION THERAPY (IOERT) USING INTRAOPERATIVE C-ARM BASED 3D-IMAGING : A PHANTOM STUDY
    Roeder, F.
    Schramm, O.
    Schwahofer, A.
    Timke, C.
    Habl, G.
    Tanner, M.
    Huber, P.
    Debus, J.
    Krempien, R.
    Hensley, F.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S246 - S247