3D POLYMER GEL DOSIMETRY FOR QUALITY ASSURANCE IN RADIATION THERAPY

被引:0
|
作者
Ceberg, Sofie [1 ]
Adliene, Diana [2 ]
Mattsson, Soren [2 ,3 ]
机构
[1] Skane Univ Hosp, Dept Haematol Oncol & Radiat Phys, Lund, Sweden
[2] Kaunas Univ Technol, Dept Phys, Kaunas, Lithuania
[3] Lund Univ, Dept Translat Med, Med Radiat Phys, Malmo, Sweden
关键词
dose gels; 3D dosimetry; Fricke and polymer gel dosemeters; 3D phantom; radiation therapy; quality assurance; ABSORBED DOSE DISTRIBUTIONS; FERROUS SULFATE GELS; MAGNETIC-RESONANCE; POLYACRYLAMIDE-GELS; HDR BRACHYTHERAPY; RAMAN-SPECTROSCOPY; NMR; MRI; VERIFICATION; IR-192;
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Three dimensional (3D) gel dosimetry plays an important role to guarantee the safety in various kinds of conformal radiation therapy. The technique enables quality assurance covering the whole treatment chain and produces time integrated 3D dose distributions in human like phantoms. It has shown to be especially valuable for the evaluation and optimisation of new treatment techniques like image guided and dose tracking radiotherapy associated with patient movement, small irradiation fields and steep dose gradients as in the case of IMRT, VMAT, tomotherapy and brachytherapy. This short overview describes various types of gel dosemeters, their advantages and limitations in relation to their clinical use and further potential.
引用
收藏
页码:30 / 35
页数:6
相关论文
共 50 条
  • [1] Quality assurance of optical computed tomography for 3D polymer gel dosimetry
    Olding, T.
    Holmes, O.
    Santyr, G.
    Nkongchu, K.
    MacAuley, K.
    Schreiner, L. J.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S53 - S53
  • [2] Patient-specific quality assurance in SBRT treatments using 3D polymer gel dosimetry
    Guadarrama-Huerta, P. J.
    Arzaga-Barajas, E.
    Rodriguez-Laguna, A.
    Jimenez-Acosta, J. A.
    Poitevin-Chacon, M. A.
    Massillon-Jl, G.
    RADIATION MEASUREMENTS, 2024, 175
  • [3] Quality assurance for 3D conformal radiation therapy
    Purdy, JA
    Harms, WB
    STRAHLENTHERAPIE UND ONKOLOGIE, 1998, 174 : 2 - 7
  • [4] Quality assurance for 3D printing in radiation therapy
    Sasaki, David
    McGeachy, Philip
    Rickey, Daniel W.
    Harris, Chad
    VanUytven, Eric
    Dubey, Arbind
    MEDICAL PHYSICS, 2017, 44 (08) : 4372 - 4372
  • [5] Polymer gel 3D dosimetry in radiotherapy
    Pappas, Evangelos
    Maris, Thomas
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2020, 30 (03): : 171 - 172
  • [6] Radiation response of an improved optical CT based 3D gel dosimeter for radiation therapy quality assurance
    Moftah, B.
    Basfar, A.
    Rabaeh, K.
    Almousa, A.
    Al Kafi, M. A.
    Devic, S.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S183 - S184
  • [7] New normoxic N-(Hydroxymethyl)acrylamide based polymer gel for 3D dosimetry in radiation therapy
    Rabaeh, Khalid A.
    Basfar, Ahmed A.
    Almousa, Akram A.
    Devic, Slobodan
    Moftah, Belal
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 33 : 121 - 126
  • [8] Thermoluminescence dosimetry for quality assurance in radiation therapy
    Kalef-Ezra, JA
    Boziari, A
    Litsas, J
    Tsekeris, P
    Koligliatis, T
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A403 - A405
  • [9] Thermoluminescence dosimetry for quality assurance in radiation therapy
    Kalef-Ezra, JA
    Boziari, A
    Litsas, J
    Tsekeris, P
    Koligliatis, T
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 403 - 405
  • [10] Design, construction, and dosimetry of 3D printed heterogeneous phantoms for synchrotron brain cancer radiation therapy quality assurance
    Bustillo, John Paul O.
    Paino, Jason
    Barnes, Micah
    Cayley, James
    de Rover, Vincent
    Cameron, Matthew
    Engels, Elette E. M.
    Tehei, Moeava
    Beirne, Stephen
    Wallace, Gordon G.
    Rosenfeld, Anatoly B.
    Lerch, Michael L. F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (14):