A methodology based on thermoluminescence dosimetry was developed to check the output of teletherapy units and the given doses. It was applied in a hospital as a part of an external quality audit programme. Over a 7 year period the mean ratios of the output doses measured by TLDs calibrated free-in-air to the doses measured at the hospital in a 6 MV X ray and in a Co-60 unit were 1.000 +/- 0.024 (a = 86) and 0.997 +/- 0.027 (n=61), respectively. TLDs in capsules were attached to the patient's body or to a phantom to assess entrance, exit and midline doses and transmission. Factors were determined experimentally to relate the doses measured with TLDs in capsules and inside the body. The accuracy in given doses with pelvic and tangential breast fields and assessed via 752 in vivo measurements, was considered to be adequately good, taking into account the limitations of the equipment available in the hospital.
引用
收藏
页码:403 / 405
页数:3
相关论文
共 50 条
  • [1] Thermoluminescence dosimetry for quality assurance in radiation therapy
    Kalef-Ezra, JA
    Boziari, A
    Litsas, J
    Tsekeris, P
    Koligliatis, T
    [J]. SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A403 - A405
  • [2] QUALITY ASSURANCE DOSIMETRY IN RADIATION ONCOLOGY
    KARTHA, P
    WACHTOR, T
    CHUNGBIN, A
    HENDRICKSON, F
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 551 - 551
  • [3] Quality assurance in radiotherapy by mailed thermoluminescence dosimetry at the patient level
    Swinnen, A
    Van Dam, J
    Van den Bogaert, W
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S194 - S194
  • [4] A unifying system for mechanical and (relative) dosimetry quality assurance in radiation therapy
    Wong, J.
    Velarde, E.
    Iordachita, I.
    Ding, K.
    Li, B.
    Ng, S.
    Le, Y.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S125 - S125
  • [5] Quality assurance study for dosimetry of radiation therapy equipment in Saudi Arabia
    Al-Mokhlef, JM
    Noori, N
    [J]. ANNALS OF SAUDI MEDICINE, 2003, 23 (3-4) : 148 - 151
  • [6] ROUTINE USE OF THERMOLUMINESCENCE DOSIMETRY FOR RADIATION-THERAPY
    GOODEN, DS
    BRICKNER, TJ
    [J]. RADIOLOGY, 1972, 102 (03) : 685 - &
  • [7] Film dosimetry studies for patient specific quality assurance in microbeam radiation therapy
    Ocadiz, Alexandre
    Livingstone, Jayde
    Donzelli, Mattia
    Bartzsch, Stefan
    Nemoz, Christian
    Kefs, Samy
    Pellicioli, Paolo
    Giraud, Jean-Yves
    Balosso, Jacques
    Krisch, Michael
    Brauer-Krisch, Elke
    Serduc, Raphael
    Adam, Jean-Francois
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 65 : 227 - 237
  • [8] Spectral fiber dosimetry with beryllium oxide for quality assurance in hadron radiation therapy
    Metzner, E.
    Baeumer, C.
    Behrends, C.
    Debbih, A. Dammene
    Doehler, D. D.
    van Goethem, M. J.
    van der Graaf, E. R.
    Kahle, P.
    Luehr, A.
    Teichmann, T.
    Timmermann, B.
    Weinberger, D.
    Werner, T.
    Wulff, J.
    Kormoll, T.
    [J]. JOURNAL OF INSTRUMENTATION, 2022, 17 (02)
  • [9] 3D POLYMER GEL DOSIMETRY FOR QUALITY ASSURANCE IN RADIATION THERAPY
    Ceberg, Sofie
    Adliene, Diana
    Mattsson, Soren
    [J]. MEDICAL PHYSICS IN THE BALTIC STATES, 2017, : 30 - 35
  • [10] Two-dimensional thermoluminescence dosimetry system for proton beam quality assurance
    Gajewski, J.
    Klosowski, M.
    Olko, P.
    [J]. RADIATION MEASUREMENTS, 2016, 90 : 224 - 227