3D POLYMER GEL DOSIMETRY FOR QUALITY ASSURANCE IN RADIATION THERAPY

被引:0
|
作者
Ceberg, Sofie [1 ]
Adliene, Diana [2 ]
Mattsson, Soren [2 ,3 ]
机构
[1] Skane Univ Hosp, Dept Haematol Oncol & Radiat Phys, Lund, Sweden
[2] Kaunas Univ Technol, Dept Phys, Kaunas, Lithuania
[3] Lund Univ, Dept Translat Med, Med Radiat Phys, Malmo, Sweden
关键词
dose gels; 3D dosimetry; Fricke and polymer gel dosemeters; 3D phantom; radiation therapy; quality assurance; ABSORBED DOSE DISTRIBUTIONS; FERROUS SULFATE GELS; MAGNETIC-RESONANCE; POLYACRYLAMIDE-GELS; HDR BRACHYTHERAPY; RAMAN-SPECTROSCOPY; NMR; MRI; VERIFICATION; IR-192;
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Three dimensional (3D) gel dosimetry plays an important role to guarantee the safety in various kinds of conformal radiation therapy. The technique enables quality assurance covering the whole treatment chain and produces time integrated 3D dose distributions in human like phantoms. It has shown to be especially valuable for the evaluation and optimisation of new treatment techniques like image guided and dose tracking radiotherapy associated with patient movement, small irradiation fields and steep dose gradients as in the case of IMRT, VMAT, tomotherapy and brachytherapy. This short overview describes various types of gel dosemeters, their advantages and limitations in relation to their clinical use and further potential.
引用
收藏
页码:30 / 35
页数:6
相关论文
共 50 条
  • [11] The potential of polymer gel dosimeters for 3D MR-IGRT quality assurance
    Roed, Y.
    Ding, Y.
    Wen, Z.
    Wang, J.
    Pinsky, L.
    Ibbott, G.
    9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [12] Application of 3D Gel Dosimetry as a Quality Assurance Tool in Functional Leksell Gamma Knife Radiosurgery
    Kudrevicius, Linas
    Jaselske, Evelina
    Adliene, Diana
    Rudzianskas, Viktoras
    Radziunas, Andrius
    Tamasauskas, Arimantas
    GELS, 2022, 8 (02)
  • [13] Quality Assurance Tests for 3D Printed Bolus Used in Radiation Therapy
    McGeachy, P.
    Sasaki, D. K.
    Harris, C.
    Sharma, A. M.
    Dubey, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E697 - E698
  • [14] Optical Scanner for 3D Radiotherapy Polymer Gel Dosimetry
    Sobotka, P.
    Kozicki, M.
    Maras, P.
    Boniecki, L.
    Kacperski, K.
    Domanski, A. W.
    ACTA PHYSICA POLONICA A, 2012, 122 (05) : 969 - 974
  • [15] On the chemical stability of 3D monomer/polymer gel dosimetry
    De Deene, Y
    De Wagter, C
    Achten, E
    De Neve, W
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 380 - 382
  • [16] 3D gel Dosimetry of IMSRT using normoxic MAGAT polymer gel
    Beiki-Ardakani, A
    Heydarian, M
    Vitkin, A
    Kirilova, A
    Princess, DJA
    MEDICAL PHYSICS, 2005, 32 (06) : 1978 - 1979
  • [17] A 3D Printed Device for the Quality Assurance of 3D Printers Used for Bolus Fabrication in Radiation Therapy
    Lowe, Hunter
    Lawyer, Kim
    Maynard, Evan
    Chng, Nick
    Matthews, Quinn
    MEDICAL PHYSICS, 2024, 51 (08) : 5806 - 5806
  • [18] Clinical 3D Dosimetry in Modern Radiation Therapy
    Mihailidis, Dimitris
    MEDICAL PHYSICS, 2020, 47 (01) : 290 - 291
  • [19] Quality Assurance for Multi-Focal Single Isocenter Stereotactic Radiosurgery Through 3D Gel Dosimetry
    Saenz, D.
    Papanikolaou, K.
    Rasmussen, K.
    Kirby, N.
    Stathakis, S.
    Pappas, E.
    Li, Y.
    MEDICAL PHYSICS, 2018, 45 (06) : E607 - E607
  • [20] Novel 3D polymer gel dosimeters based on N-(3-Methoxypropyl)acrylamide (NMPAGAT) for quality assurance in radiation oncology
    Moftah, Belal
    Basfar, Ahmed A.
    Almousa, Akram A.
    Al Kafi, Abdullah M.
    Rabaeh, Khalid A.
    RADIATION MEASUREMENTS, 2020, 135 (135)