A comparison of treatment plan quality between Tri-Co-60 intensity modulated radiation therapy and volumetric modulated arc therapy for cervical cancer

被引:15
|
作者
Park, Jong Min [1 ,2 ,3 ,4 ]
Park, So-Yeon [1 ,2 ,3 ]
Kim, Jung-in [1 ,2 ,3 ]
Kang, Hyun-Cheol [1 ,2 ,3 ]
Choi, Chang Heon [1 ,2 ,3 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiat Oncol, Seoul, South Korea
[2] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul, South Korea
[3] Seoul Natl Univ Hosp, Biomed Res Inst, Seoul, South Korea
[4] Adv Inst Convergence Technol, Ctr Convergence Res Robot, Suwon, South Korea
关键词
Volumetric modulated arc therapy; Intensity-modulated radiation therapy; Cervical cancer; MRI; Image guided radiotherapy; LINEAR-ACCELERATOR; PROSTATE-CANCER; ORGAN MOTION; RADIOTHERAPY; SYSTEM; IMRT; ENDOMETRIAL;
D O I
10.1016/j.ejmp.2017.06.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the plan quality of tri-Co-60 intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) for cervical cancer. Methods: A total of 20 patients who received postoperative radiotherapy for cervical cancer were selected. For each patient, a tri-Co-60 IMRT plan for which the target volume was the planning target volume (PTV) generated by adding 1 mm isotropic margins from the clinical target volume (CTV) and a VMAT plan for which the target volume was the PTV generated by adding 7 mm and 10 mm margins from the CTV were generated. The tri-Co-60 IMRT plans were generated with the ViewRay (TM) system while the VMAT plans were generated with 15-MV photon beams from a linear accelerator (prescription dose = 50.4 Gy in 28 fractions). Results: The average volumes of the PTVs and CTVs were 704.9 cc +/- 87.8 cc and 271.6 cc +/- 51.6 cc, respectively. No noticeable differences in the dose-volumetric parameters for the target volumes were observed between the tri-Co-60 IMRT and VMAT plans. The values of V-40Gy for the small bowel and rectal wall, V-45Gy of the bladder, and V-35Gy of the femoral heads for the VMAT plans were 14.6% +/- 7.8%, 54.4% +/- 4.2%, 30.0% +/- 4.7%, and 8.9% +/- 3.3%, respectively. Those of the tri-Co-60 IMRT plans were 2.8% +/- 2.1%, 23.0% +/- 8.9%, 17.1% +/- 6.1%, and 0.3% +/- 0.4%, respectively. Conclusions: Owing to the target margin reduction capability, the tri-Co-60 IMRT plans were more favorable than the VMAT plans for cervical cancer. (C) 2017 Published by Elsevier Ltd on behalf of Associazione Italiana di Fisica Medica.
引用
收藏
页码:11 / 16
页数:6
相关论文
共 50 条
  • [21] Comparison of three-dimensional conformal radiation therapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy in the treatment of cervical esophageal carcinoma
    Yang, Hao
    Feng, Cong
    Cai, Bo-Ning
    Yang, Jun
    Liu, Hai-Xia
    Ma, Lin
    DISEASES OF THE ESOPHAGUS, 2017, 30 (02):
  • [22] A dosimetric comparison of volumetric modulated arc therapy with step-and-shoot intensity modulated radiation therapy for prostate cancer
    Mellon, Eric A.
    Javedan, Khosrow
    Strom, Tobin J.
    Moros, Eduardo G.
    Biagioli, Matthew C.
    Fernandez, Daniel C.
    Wasserman, Stu G.
    Wilder, Richard B.
    PRACTICAL RADIATION ONCOLOGY, 2015, 5 (01) : 11 - 15
  • [23] Volumetric Modulated Arc Therapy for Brain Tumors: Dosimetric Comparison with Intensity-Modulated Radiation Therapy
    Ter-Antonyan, R.
    Yang, W.
    Geesey, C.
    Lain, D.
    Larner, J.
    Benedict, S.
    MEDICAL PHYSICS, 2010, 37 (06) : 3213 - +
  • [24] Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for pancreatic malignancies
    Ali, Arif N.
    Dhabaan, Anees H.
    Jarrio, Christie S.
    Siddiqi, Arsalan K.
    Landry, Jerome C.
    MEDICAL DOSIMETRY, 2012, 37 (03) : 271 - 275
  • [25] The Dosimetric Performance of Volumetric Modulated Arc Therapy and Intensity Modulated Radiation Therapy in the Treatment of Locally Advanced Laryngeal Cancer
    Khater, Firas
    Attalla, Ehab
    Elshemey, Wael
    Mohammed, Haitham
    MIDDLE EAST JOURNAL OF CANCER, 2024, 15 (01) : 25 - 39
  • [26] Treatment Efficiency of Volumetric Modulated Arc Therapy in Comparison With Intensity-Modulated Radiotherapy in the Treatment of Prostate Cancer
    Hall, William A.
    Fox, Timothy H.
    Jiang, Xiaojun
    Prabhu, Roshan S.
    Rossi, Peter J.
    Godette, Karen
    Jani, Ashesh B.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2013, 10 (02) : 128 - 134
  • [27] Dosimetric comparison of hybrid volumetric-modulated arc therapy, volumetric-modulated arc therapy, and intensity-modulated radiation therapy for left-sided early breast cancer
    Lin, Jia-Fu
    Yeh, Dah-Cherng
    Yeh, Hui-Ling
    Chang, Chen-Fa
    Lin, Jin-Ching
    MEDICAL DOSIMETRY, 2015, 40 (03) : 262 - 267
  • [28] Dosimetric Comparison of Coplanar Volumetric Modulated Arc Therapy and Non-coplanar Intensity Modulated Radiation Therapy for Pancreatic Cancer
    Badkul, R. K.
    Kile, L.
    Saleh, H.
    Chen, A. M.
    Lominska, C. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E635 - E636
  • [29] Treatment Plan Technique and Quality for Single Isocenter Stereotactic Ablative Radiation Therapy of Multiple Lung Lesions With Volumetric Modulated Arc Therapy or Intensity Modulated Radiosurgery
    Quan, K.
    Xu, K. M.
    Horne, Z. D.
    Clump, D. A., II
    Lalonde, R.
    Burton, S. A.
    Heron, D. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E389 - E389
  • [30] Dosimetric Comparison of Volumetric Modulated Arc Therapy and Intensity Modulated Radiation Therapy for Soft Tissue Sarcoma of the Extremities
    Lawless, Anna K.
    Fangupo, Nonga
    Estoesta, Reuben Patrick
    Perez, Gino
    Alzaidi, Samara
    Heller, Gillian
    Hill, Robin
    Hong, Angela M.
    PRACTICAL RADIATION ONCOLOGY, 2022, 12 (04) : E306 - E311