Treatment Efficiency of Volumetric Modulated Arc Therapy in Comparison With Intensity-Modulated Radiotherapy in the Treatment of Prostate Cancer

被引:16
|
作者
Hall, William A. [1 ]
Fox, Timothy H.
Jiang, Xiaojun
Prabhu, Roshan S.
Rossi, Peter J.
Godette, Karen
Jani, Ashesh B.
机构
[1] Emory Univ, Dept Radiat Oncol, Atlanta, GA 30322 USA
关键词
Treatment efficiency prostate cancer; VMAT; IMRT treatment efficiency; INTRAFRACTION MOTION; HELICAL TOMOTHERAPY; RADIATION-THERAPY; CLINICAL-EXPERIENCE; IMRT; LOCALIZATION; VMAT; DELIVERY; SYSTEM;
D O I
10.1016/j.jacr.2012.06.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Treatment with intensity-modulated radiation therapy (IMRT) is increasingly standard for prostate cancer. Volume-modulated arc therapy (VMAT) to deliver IMRT potentially enables shorter treatment time. The aim of this study was to test this hypothesis by measuring the average patient in-room time with VMAT versus dynamic multileaf collimator (DMLC) IMRT. Methods: Custom institutional software (RTMetrix) was used to mine the treatment times from the record-and-verify database. The in-room time (the time between patient entry and exit) was computed for each patient using RTMetrix. Average room time was compared between VMAT patients (n = 44) and IMRT patients (n = 99). Subgroup comparisons (1-arc or 2-arc VMAT, 5-field or 7-field IMRT, and electromagnetic transponder [Calypso] or gold-marker tracking) were performed. For all comparisons, 2-tailed, 2-sample, equal variance Student's t-tests were used. Results: Average room time was significantly shorter for all VMAT versus DMLC IMRT (P = .0014) procedures, along with VMAT versus 7-field DMLC IMRT (P < .001), but not VMAT versus 5-field DMLC IMRT (P = .81). Room time was longer for Calypso versus gold seed patients (P < .001), but VMAT reduced treatment time in Calypso patients (P = .01). This resulted in Calypso VMAT patients' having similar treatment times to non-Calypso DMLC IMRT patients (P = .220). Conclusions: These data show that VMAT can shorten room times and improve patient throughput over 7-field DMLC IMRT. Additionally, the data demonstrate that treatment with VMAT permits the use of advanced prostate tracking (Calypso), resulting in similar room times as with standard 7-field DMLC IMRT with conventional tracking.
引用
收藏
页码:128 / 134
页数:7
相关论文
共 50 条
  • [1] VOLUMETRIC ARC INTENSITY-MODULATED THERAPY FOR SPINE BODY RADIOTHERAPY: COMPARISON WITH STATIC INTENSITY-MODULATED TREATMENT
    Wu, Q. Jackie
    Yoo, Sua
    Kirkpatrick, John P.
    Thongphiew, Danthai
    Yin, Fang-Fang
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (05): : 1596 - 1604
  • [2] Volumetric modulated arc therapy in differentiated thyroid cancer: a treatment planning comparison with intensity-modulated radiotherapy
    Chan, Wing Lok
    Ng, Sherry C. Y.
    Law, Martin W. M.
    Lee, Victor H. F.
    Wan, K. Y.
    Leung, T. W.
    [J]. JOURNAL OF RADIATION ONCOLOGY, 2015, 4 (04) : 417 - 422
  • [3] RapidArc Volumetric Modulated Therapy for Localized Prostate Cancer: Comparison with Intensity-modulated Radiotherapy
    Csiki, I.
    Crass, J.
    Ding, G.
    Coffey, C.
    Hallahan, D. H.
    Malcolm, A. M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S731 - S731
  • [4] Dosimetric Comparison of Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Radiotherapy for the Treatment of Multiple Intracranial Metastases
    Liu, X.
    Yin, Y.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2912 - 2912
  • [5] Dosimetric Comparison of Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Radiotherapy for the Treatment of Multiple Intracranial Metastases
    Lin, X.
    Sun, T.
    Yin, Y.
    Liu, T.
    Lu, J.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3683 - +
  • [6] The Use of Data Mining to Measure the Efficiency of Volumetric Modulated Arc Therapy (VMAT) in Comparison to Intensity Modulated Radiotherapy (IMRT) in the Treatment of Prostate Cancer
    Hall, W. A.
    Fox, T. H.
    Jiang, X.
    Prabhu, R. S.
    Rossi, P. J.
    Godette, K.
    Jani, A. B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S159 - S159
  • [7] Dosimetric Comparison of Intensity-Modulated Radiotherapy and Volumetric Arc Therapy for Rectal Cancer
    Oskeroglu Kaplan, Sedenay
    Akboru, Halil
    Sarali, Yunus
    Altin, Suleyman
    Unsal, Mustafa
    [J]. TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2019, 34 (02): : 59 - 65
  • [8] Optimized intensity-modulated arc therapy for prostate cancer treatment
    Ma, LJ
    Yu, CX
    Earl, M
    Holmes, T
    Sarfaraz, M
    Li, XA
    Shepard, D
    Amin, P
    DiBiase, S
    Suntharalingam, M
    Mansfield, C
    [J]. INTERNATIONAL JOURNAL OF CANCER, 2001, 96 (06) : 379 - 384
  • [9] VOLUMETRIC MODULATED ARC THERAPY FOR DELIVERY OF PROSTATE RADIOTHERAPY: COMPARISON WITH INTENSITY-MODULATED RADIOTHERAPY AND THREE-DIMENSIONAL CONFORMAL RADIOTHERAPY
    Palma, David
    Vollans, Emily
    James, Kerry
    Nakano, Sandy
    Moiseenko, Vitali
    Shaffer, Richard
    Mckenzie, Michael
    Morris, James
    Otto, Karl
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (04): : 996 - 1001
  • [10] Volumetric Modulated Arc Therapy for Spine Body Radiotherapy: Comparison with Static Intensity Modulated Treatment
    Wu, Q.
    Yoo, S.
    Kirkpatrick, J.
    McMahon, R.
    Thongphiew, D.
    Yin, F.
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 2655 - +