Dosimetric comparison of hybrid volumetric-modulated arc therapy, volumetric-modulated arc therapy, and intensity-modulated radiation therapy for left-sided early breast cancer

被引:35
|
作者
Lin, Jia-Fu [1 ]
Yeh, Dah-Cherng [2 ]
Yeh, Hui-Ling [3 ]
Chang, Chen-Fa [1 ]
Lin, Jin-Ching [3 ]
机构
[1] Taichung Vet Gen Hosp, Dept Radiat Phys, Taichung 40705, Taiwan
[2] Taichung Vet Gen Hosp, Dept Gen Surg, Taichung 40705, Taiwan
[3] Taichung Vet Gen Hosp, Dept Radiat Oncol, Taichung 40705, Taiwan
关键词
Hybrid volumetric-modulated arc therapy; Volumetric-modulated arc therapy; Intensity-modulated radiotherapy; Left-sided breast cancer; TOTAL MASTECTOMY; FOLLOW-UP; IRRADIATION; LUMPECTOMY;
D O I
10.1016/j.meddos.2015.05.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To compare the dosimetric performance of 3 different treatment techniques: hybrid volumetric-modulated arc therapy (hybrid-VMAT), pure-VMAT, and fixed-field intensity-modulated radiation therapy (F-IMRT) for whole-breast irradiation of left-sided early breast cancer. The hybrid-VMAT treatment technique and 2 other treatment techniques pure-VMAT and F-IMRT were compared retrospectively in 10 patients with left-sided early breast cancer. The treatment plans of these patients were replanned using the same contours based on the original computed tomography (CT) data sets. Dosimetric parameters were calculated to evaluate plan quality. Total monitor units (MUs) and delivery time were also recorded and evaluated. The hybrid-VMAT plan generated the best results in dose coverage of the target and the dose uniformity inside the target (p < 0.0001 for conformal index [CI]; p 0.0002 for homogeneity index [HI] of planning target volume [PTV](50.4 Gy) and p < 0.0001 for HI of PTV62 Gy). Volumes of ipsilateral lung irradiated to doses of 20 Gy (V-20 Gy) and 5 Gy (V-5 Gy) by the hybrid-VMAT plan were significantly less than those of the F-IMRT and the pure-VMAT plans. The volume of ipsilateral lung irradiated to a dose of 5 Gy was significantly less using the hybrid-VMAT plan than that using the F-IMRT or the pure-VMAT plan. The total mean MUs for the hybrid-VMAT plan were significantly less than those for the F-IMRT or the pure-VMAT plan. The mean machine delivery time was 3.23 +/- 0.29 minutes for the hybrid-VMAT plans, which is longer than that for the pure-VMAT plans but shorter than that for the F-IMRT plans. The hybrid-VMAT plan is feasible for whole-breast irradiation of left-sided early breast cancer. (C) 2015 American Association of Medical Dosimetrists.
引用
收藏
页码:262 / 267
页数:6
相关论文
共 50 条
  • [1] Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison
    Hou, Yong
    Zhang, Yan
    Liu, Zhen
    Yv, Lili
    Liu, Kun
    Tian, Xiufang
    Lv, Yajuan
    [J]. CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 187
  • [2] Helical Tomotherapy for left-sided breast: dosimetric comparison to Volumetric-Modulated Arc Therapy
    Ertan, F.
    Tanriseven, R.
    Yazici, O.
    Kocer, A. M.
    Altundag, M. B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S796 - S797
  • [3] Dosimetric analysis and comparison of volumetric-modulated arc therapy versus intensity-modulated radiation therapy for liver carcinoma
    Chiang, Bing-Hao
    Schnell, Erich
    Hibbitts, Kerry
    Herman, Terence
    Ahmad, Salahuddin
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 138 - 140
  • [4] Dosimetric comparison of volumetric-modulated arc therapy and intensity-modulated radiation therapy in patients with cervical cancer: a meta-analysis
    Bai, Wei
    Kou, Changgui
    Yu, Weiying
    Li, Yuanyuan
    Hua, Wanqing
    Yu, Lei
    Wang, Jianfeng
    [J]. ONCOTARGETS AND THERAPY, 2018, 11 : 7179 - 7186
  • [5] A Dosimetric Comparison of Volumetric-Modulated Arc Therapy to Intensity-Modulated Radiation Therapy in the Treatment of Locally Advanced Rectal Carcinoma
    Eldebawy, Eman
    Rashed, Yasser A
    AlKhaldi, Mashaal
    Day, Emma
    [J]. Iranian Journal of Medical Physics, 2020, 17 (06) : 374 - 379
  • [6] Dosimetric Comparison of Helical Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy for Angiosarcoma of the Scalp
    Mizuno, Tomoki
    Tomita, Natsuo
    Takaoka, Taiki
    Tomida, Masashi
    Fukuma, Hiroshi
    Tsuchiya, Takahiro
    Shibamoto, Yuta
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2021, 20
  • [7] Validation of Delivery Consistency for Intensity-Modulated Radiation Therapy and Volumetric-Modulated Arc Therapy Plans
    Woon, Wui Ann
    Ravindran, Paul B.
    Ekayanake, Piyasiri
    Lim, Yivonne Yih Fang
    [J]. JOURNAL OF MEDICAL PHYSICS, 2018, 43 (02) : 119 - 128
  • [8] Dosimetric Comparison to Organs at Risk Sparing Using Volumetric-Modulated Arc Therapy Versus Intensity-Modulated Radiotherapy in Postoperative Radiotherapy of Left-Sided Breast Cancer
    Qiao, L.
    Xie, J.
    Cheng, J.
    Liang, N.
    Deng, G.
    Zhang, J.
    Zhang, J.
    Luo, H.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3238 - 3238
  • [9] Dosimetric comparison between intensity-modulated radiotherapy and volumetric-modulated arc therapy in patients of left-sided breast cancer treated with modified radical mastectomy CONSORT
    Wang, Rui
    Shen, Jun
    Yan, Huanhuan
    Gao, Xitao
    Dong, Tianfu
    Li, Shuqin
    Wang, Peishun
    Zhou, Jun
    [J]. MEDICINE, 2022, 101 (02)
  • [10] Comparison of volumetric-modulated arc therapy and intensity-modulated radiation therapy prostate cancer plans accounting for cold spots
    Tran Thi Thao Nguyen
    Arimura, Hidetaka
    Asamura, Ryosuke
    Hirose, Taka-aki
    Ohga, Saiji
    Fukunaga, Jun-ichi
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2019, 12 (02) : 137 - 148