Comparison of volumetric-modulated arc therapy and intensity-modulated radiation therapy prostate cancer plans accounting for cold spots

被引:6
|
作者
Tran Thi Thao Nguyen [1 ,4 ]
Arimura, Hidetaka [2 ]
Asamura, Ryosuke [1 ]
Hirose, Taka-aki [1 ,3 ]
Ohga, Saiji [2 ]
Fukunaga, Jun-ichi [3 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Hlth Sci, Div Med Quantum Sci,Higashi Ku, 3-1-1 Maidashi, Fukuoka, Fukuoka 8128582, Japan
[2] Kyushu Univ, Fac Med Sci, Dept Hlth Sci, Div Med Quantum Sci,Higashi Ku, 3-1-1 Maidashi, Fukuoka, Fukuoka 8128582, Japan
[3] Kyushu Univ Hosp, Dept Med Technol, Higashi Ku, 3-1-1 Maidashi, Fukuoka, Fukuoka 8128582, Japan
[4] Japan Soc Promot Sci, Chiyoda Ku, 5-3-1 Kojimachi, Tokyo 1020083, Japan
基金
日本学术振兴会;
关键词
Prostate cancer; Cold spot; VMAT; IMRT; Probabilistic distribution; EXTERNAL-BEAM RADIOTHERAPY; SHAPE VARIATIONS; IMRT; CONFORMITY; GUIDELINES; ACCURACY; DELIVERY; INDEX;
D O I
10.1007/s12194-019-00502-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study compared dosimetric indices of volumetric-modulated arc therapy (VMAT) with intensity-modulated radiation therapy (IMRT) accounting for cold spots in prostate cancer plans. IMRT plans were retrospectively generated from 30 prostate cancer patients with ten cases for each risk group, who received VMAT plans. The mean, maximum, and minimum doses, and conformity and homogeneity indexes were evaluated for planning target volume (PTV) and the mean dose and V20-V70 for organs at risk (OAR) including the rectum, bladder, right and left femoral heads, and rectum overlapped with PTV (ROP) regions. The numbers and volume percentages of cold spots within PTVs and ROP regions were measured using in-house software. Three-dimensional probabilistic distributions of the probability and distributions of cold spots were generated using a centroid matching technique for visualization and analysis. There was a statistically better dose conformity in the PTV, rectum, and bladder dose-sparing in VMAT compared to that in the IMRT plans, whereas VMAT had statistically worse target dose homogeneity, and right and left femoral head dose-sparing than those of the IMRT plans. The average volume percentage of cold spots per PTV for the VMAT was 4.37 +/- 2.68%, which was smaller than the 5.72 +/- 1.84% observed for IMRT plans (P=0.007). The volume percentage of cold spots per ROP for the VMAT did not significantly differ from those for the IMRT plans. Compared with IMRT, the VMAT plans achieved better PTV dose conformity, OAR dose-sparing, and smaller cold spots in the treatment of prostate cancer.
引用
收藏
页码:137 / 148
页数:12
相关论文
共 50 条
  • [1] Comparison of volumetric-modulated arc therapy and intensity-modulated radiation therapy prostate cancer plans accounting for cold spots
    Tran Thi Thao Nguyen
    Hidetaka Arimura
    Ryosuke Asamura
    Taka-aki Hirose
    Saiji Ohga
    Jun-ichi Fukunaga
    Radiological Physics and Technology, 2019, 12 : 137 - 148
  • [2] Validation of Delivery Consistency for Intensity-Modulated Radiation Therapy and Volumetric-Modulated Arc Therapy Plans
    Woon, Wui Ann
    Ravindran, Paul B.
    Ekayanake, Piyasiri
    Lim, Yivonne Yih Fang
    JOURNAL OF MEDICAL PHYSICS, 2018, 43 (02) : 119 - 128
  • [3] Dosimetric comparison of hybrid volumetric-modulated arc therapy, volumetric-modulated arc therapy, and intensity-modulated radiation therapy for left-sided early breast cancer
    Lin, Jia-Fu
    Yeh, Dah-Cherng
    Yeh, Hui-Ling
    Chang, Chen-Fa
    Lin, Jin-Ching
    MEDICAL DOSIMETRY, 2015, 40 (03) : 262 - 267
  • [4] Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison
    Hou, Yong
    Zhang, Yan
    Liu, Zhen
    Yv, Lili
    Liu, Kun
    Tian, Xiufang
    Lv, Yajuan
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 187
  • [5] Comparison of testicular dose delivered by intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with prostate cancer
    Martin, Jeffrey M.
    Handorf, Elizabeth A.
    Price, Robert A.
    Cherian, George
    Buyyounouski, Mark K.
    Chen, David Y.
    Kutikov, Alexander
    Johnson, Matthew E.
    Ma, Chung-Ming Charlie
    Horwitz, Eric M.
    MEDICAL DOSIMETRY, 2015, 40 (03) : 186 - 189
  • [6] Dosimetric analysis and comparison of volumetric-modulated arc therapy versus intensity-modulated radiation therapy for liver carcinoma
    Chiang, Bing-Hao
    Schnell, Erich
    Hibbitts, Kerry
    Herman, Terence
    Ahmad, Salahuddin
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 138 - 140
  • [7] Plan comparison of volumetric-modulated arc therapy (RapidArc) and conventional intensity-modulated radiation therapy (IMRT) in anal canal cancer
    Vieillot, Sabine
    Azria, David
    Lemanski, Claire
    Moscardo, Carmen Llacer
    Gourgou, Sophie
    Dubois, Jean-Bernard
    Ailleres, Norbert
    Fenoglietto, Pascal
    RADIATION ONCOLOGY, 2010, 5
  • [8] Plan comparison of volumetric-modulated arc therapy (RapidArc) and conventional intensity-modulated radiation therapy (IMRT) in anal canal cancer
    Sabine Vieillot
    David Azria
    Claire Lemanski
    Carmen Llacer Moscardo
    Sophie Gourgou
    Jean-Bernard Dubois
    Norbert Aillères
    Pascal Fenoglietto
    Radiation Oncology, 5
  • [9] Dosimetric comparison of volumetric-modulated arc therapy and intensity-modulated radiation therapy in patients with cervical cancer: a meta-analysis
    Bai, Wei
    Kou, Changgui
    Yu, Weiying
    Li, Yuanyuan
    Hua, Wanqing
    Yu, Lei
    Wang, Jianfeng
    ONCOTARGETS AND THERAPY, 2018, 11 : 7179 - 7186
  • [10] Comparison of Intensity-Modulated Radiation Therapy, Intensity-Modulated Arc Therapy and Arc-Modulated Radiation Therapy
    Tang, G.
    Earl, M.
    Luan, S.
    Wang, C.
    Naqvi, S.
    Yu, C.
    MEDICAL PHYSICS, 2008, 35 (06)