Effect of abutment finish lines on the mechanical behavior and marginal fit of screw-retained implant crowns: An in vitro study

被引:0
|
作者
Garcia-Gonzalez, Marta
Gonzalez-Gonzalez, Ignacio [1 ]
Garcia-Garcia, Ismael [2 ]
Blason-Gonzalez, Sergio [3 ]
Lamela-Rey, Maria Jesus [2 ]
Fernandez-Canteli, Alfonso [2 ]
Alvarez-Arenal, Angel [1 ]
机构
[1] Univ Oviedo, Sch Dent, Dept Prosthodont & Occlus, Catedrat Serrano S-N, Oviedo 33006, Spain
[2] Univ Oviedo, Dept Construct & Mfg Engn, Campus Viesques, Gijon, Spain
[3] Bundesanstalt Materialforsch & Prufung BAM, Dept Component Safety, Berlin, Germany
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2022年 / 127卷 / 02期
关键词
FRACTURE; CAD/CAM; SYSTEM; MISFIT;
D O I
10.1016/j.prosdent.2021.08.028
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The design of the implant-abutment connection has been widely researched, but the impact of different crown-abutment geometries remains unclear. Purpose. The purpose of this in vitro study was to evaluate the effect of different crown-abutment margin geometries on the mechanical behavior and fit of screw-retained implant-supported single-crown restorations by using mechanical static and fatigue tests and mastication simulation. Material and methods. A total of 45 cobalt-chromium premolar-shaped metal frameworks were fabricated for single-unit implant-supported screw-retained restorations on stock abutments and internal hexagon empty set4.25x11-mm cylindrical implants. They were divided into 3 groups according to margin geometry: S, shoulder; C, chamfer; and F, feather-edge. Three static load until fracture and 24 dynamic load tests were performed by using the International Organization for Standardization 14801:2016 standard (ISO 14801:2016) (number of cycles limit: 5x10(6) cycles, frequency: 6 Hz). The ProFatigue software program was used to optimize the procedure (S, n=12 specimens; C, n=7 specimens; and F, n=5 specimens). Six additional specimens from each group were subjected to a mastication simulation (limit number of cycles: 1x10(6) cycles, cyclic loading from P-min=30 N to P-max=300 N, frequency: 6 Hz). Results from the fatigue tests were reported descriptively, and the Fisher exact test was used to analyze the difference in failure modes. Data from maximum misfit were evaluated by photogrammetry and statistically analyzed with the Anderson-Darling test and the Kruskal-Wallis and Dunn multiple comparison tests (alpha=.05). Results. The fatigue limit was 456 N for group S, 512 N for group C, and 514 N for group F. The mean +/- standard deviation misfit was 2.6 +/- 0.1 mu m for group S, 3.8 +/- 1.1 mu m for group C, and 3.6 +/- 0.8 mu m for group F. Differences in misfit between groups S and C and between groups S and F were statistically significant (P<.05). Conclusions. Crown-abutment connections with chamfer and feather-edge margins showed better mechanical behavior, while shoulder margin exhibited better fit. However, high levels of fit were achieved for all the evaluated geometries.
引用
收藏
页码:318.e1 / 318.e10
页数:10
相关论文
共 50 条
  • [41] In vitro validation of Digital Image Analysis Sequence (DIAS) for the assessment of the marginal fit of cement-retained implant-supported experimental crowns
    Villias, Aristeidis A.
    Kourtis, Stefanos G.
    Karkazis, Hercules C.
    Polyzois, Gregory L.
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [42] Five-year randomized controlled clinical study comparing cemented and screw-retained zirconia-based implant-supported single crowns
    Kraus, Riccardo D.
    Espuelas, Catharina
    Hammerle, Christoph H. F.
    Jung, Ronald E.
    Sailer, Irena
    Thoma, Daniel S.
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (05) : 537 - 547
  • [43] The influence of stiffness of implant-abutment connection on load-deflection ratios of a screw-retained stiff cantilever beam. 3-D measurements in vitro
    Cassel, Bjorn
    Lundgren, Dan
    Karlsson, Dan
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (11) : 1251 - 1256
  • [44] The Mechanical Behavior of a Screwless Morse Taper Implant-Abutment Connection: An In Vitro Study
    Bagegni, Aimen
    Weihrauch, Vincent
    Vach, Kirstin
    Kohal, Ralf
    MATERIALS, 2022, 15 (09)
  • [46] Effect of different implant angulations on the biomechanical performance of prosthetic screws in two implant-supported, screw-retained prostheses: A numerical and experimental study
    Chen, Jianyu
    Guo, Jiaer
    Yang, Lijia
    Wang, Lin
    Zhang, Xiao
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (02): : 240.e1 - 240.e10
  • [47] Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study
    Kanneganti, Krishna Chaitanya
    Vinnakota, Dileep Nag
    Pottem, Srinivas Rao
    Pulagam, Mahesh
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2018, 18 (02): : 161 - 167
  • [48] Dental implant-abutment fracture resistance and wear induced by single-unit screw-retained CAD components fabricated by four CAM methods after mechanical cycling
    Markarian, Roberto A.
    Galles, Deborah P.
    Franca, Fabiana M. G.
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03): : 450 - 457
  • [49] The Effects of Scaling and Root Planing on the Marginal Gap and Microleakage of Indirect Composite Crowns Prepared With Different Finish Lines: An In Vitro Study
    Angerame, D.
    Sorrentino, R.
    Cettolin, D.
    Zarone, F.
    OPERATIVE DENTISTRY, 2012, 37 (06) : 650 - 659
  • [50] Effect of Cyclic Loading on Abutment Screw Loosening in Angled Implant Abutments-An In-vitro Study
    Ahmed, Syed Ershad
    Krishnan, Chitra Shankar
    Mohan, Jayashree
    Kalaignan, Parithimar
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (02)