Effect of Cyclic Loading on Abutment Screw Loosening in Angled Implant Abutments-An In-vitro Study

被引:3
|
作者
Ahmed, Syed Ershad [1 ]
Krishnan, Chitra Shankar [2 ]
Mohan, Jayashree [1 ]
Kalaignan, Parithimar [1 ]
机构
[1] Vinayaka Missions Sankarachariar Dent Coll, Dept Prosthodont, Salem, Tamil Nadu, India
[2] Ragas Dent Coll, Dept Prosthodont, Chennai, Tamil Nadu, India
关键词
Custom cast abutments; Preload loss; Premachined abutments; Reverse torque value; MISFIT;
D O I
10.7860/JCDR/2019/37807.12585
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Axis of loading can impact the effect of abutment fit to implant, thereby affecting the implant-abutment screw joint preload leading to screw loosening. Aim: The aim of the in-vitro study was to comparatively evaluate the effect of cyclic loading on abutment screw loosening of 25 degrees angled premachined titanium abutments with that of 25 degrees angled custom cast cobalt chromium (Co-Cr) abutments. Materials and Methods: Premachined titanium abutments (Group I) and custom cast cobalt-chromium abutments (Co-Cr) (Group II), 10 each of 25 degrees angulation were connected to their respective titanium implants mounted in stainless steel blocks. Cement-cum-screw retained nickel-chromium cast crowns were fabricated. Abutment screws were torqued to 35 Ncm. Reverse torque values were measured using digital torque meter before and after cyclic loading simulating six months of function. The results were statistically analysed using Paired t-test and Independent t-test. Results: Mean pre-cyclic loading reverse torque values were 28.96 Ncm (Group I) and 26.01 Ncm (Group II) and mean post-cyclic loading reverse torque values were 25.84 Ncm (Group I) and 23.82 Ncm (Group II) respectively. Cyclic loading resulted in significantly lesser reverse torque values within both test groups (p<0.01). There was significantly greater loss of preload for Group II samples both prior to and after cyclic loading compared to Group I samples (p<0.01). Conclusion: Cyclic loading resulted in significant screw loosening within both test groups. Screw loosening was found to be significantly less for angled premachined titanium abutments than for angled custom cast Co-Cr abutments both before and after cyclic loading. The study is clinically significant regarding the importance of screw joint-abutment connection acting in a maxillary anterior implant region under load and the consequences of poor connection. The study is important in the aspect of clinical implications of angled implant abutments and the effect of loading on them.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Effect of implant abutment connection designs, and implant diameters on screw loosening before and after cyclic loading: In-vitro study
    Sammour, Sara Reda
    El-Sheikh, Mohamed Maamoun
    El-Gendy, Attiah Aly
    DENTAL MATERIALS, 2019, 35 (11) : E265 - E271
  • [2] Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system
    Khraisat, A
    Hashimoto, A
    Nomura, S
    Miyakawa, O
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 91 (04): : 326 - 334
  • [3] Effect of dynamic cyclic loading on screw loosening of retightened versus new abutment screw in both narrow and standard implants (in-vitro study)
    Attiah, Eman Mohammed Nasr
    AlGendy, Attiah Ali
    Mostafa, Tamer Mohamed Nasr
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [4] Effect of dynamic cyclic loading on screw loosening of retightened versus new abutment screw in both narrow and standard implants (in-vitro study)
    Eman Mohammed Nasr Attiah
    Attiah Ali AlGendy
    Tamer Mohamed Nasr Mostafa
    International Journal of Implant Dentistry, 6
  • [5] Effect of changes in implants and cyclic loading in the abutment screw loosening
    Valente, M. G. S.
    Faria, A. C. L.
    Ribeiro, R. F.
    Rocha, S. S.
    JOURNAL OF OSSEOINTEGRATION, 2020, 12 (02) : 167 - 171
  • [6] Zirconium implant abutments: Fracture strength and influence of cyclic loading on retaining-screw loosening
    Gehrke, P
    Dhom, G
    Brunner, J
    Wolf, D
    Degidi, M
    Piattelli, D
    QUINTESSENCE INTERNATIONAL, 2006, 37 (01): : 19 - 26
  • [7] Abutment screw loosening of endosseous dental implant body/abutment joint by cyclic torsional loading test at the initial stage
    Katsuta, Yasuhiro
    Watanabe, Fumihiko
    DENTAL MATERIALS JOURNAL, 2015, 34 (06) : 896 - 902
  • [8] Study of screw loosening in cementation type implant abutment
    Hwang, BY
    Kim, YS
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1267 - 1267
  • [9] Effect of different angulations and collar lengths of conical hybrid implant abutment on screw loosening after dynamic cyclic loading
    El-Sheikh, Mai Ahmed Yousry
    Mostafa, Tamer Mohamed Nasr
    El-Sheikh, Mohamed Maamoun
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
  • [10] A study on the abutment screw loosening phenomenon of dental implant
    Kang, YM
    Cho, IH
    JOURNAL OF DENTAL RESEARCH, 1996, 75 (05) : 1261 - 1261