Effect of Cyclic Loading on Abutment Screw Loosening in Angled Implant Abutments-An In-vitro Study

被引:3
|
作者
Ahmed, Syed Ershad [1 ]
Krishnan, Chitra Shankar [2 ]
Mohan, Jayashree [1 ]
Kalaignan, Parithimar [1 ]
机构
[1] Vinayaka Missions Sankarachariar Dent Coll, Dept Prosthodont, Salem, Tamil Nadu, India
[2] Ragas Dent Coll, Dept Prosthodont, Chennai, Tamil Nadu, India
关键词
Custom cast abutments; Preload loss; Premachined abutments; Reverse torque value; MISFIT;
D O I
10.7860/JCDR/2019/37807.12585
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Axis of loading can impact the effect of abutment fit to implant, thereby affecting the implant-abutment screw joint preload leading to screw loosening. Aim: The aim of the in-vitro study was to comparatively evaluate the effect of cyclic loading on abutment screw loosening of 25 degrees angled premachined titanium abutments with that of 25 degrees angled custom cast cobalt chromium (Co-Cr) abutments. Materials and Methods: Premachined titanium abutments (Group I) and custom cast cobalt-chromium abutments (Co-Cr) (Group II), 10 each of 25 degrees angulation were connected to their respective titanium implants mounted in stainless steel blocks. Cement-cum-screw retained nickel-chromium cast crowns were fabricated. Abutment screws were torqued to 35 Ncm. Reverse torque values were measured using digital torque meter before and after cyclic loading simulating six months of function. The results were statistically analysed using Paired t-test and Independent t-test. Results: Mean pre-cyclic loading reverse torque values were 28.96 Ncm (Group I) and 26.01 Ncm (Group II) and mean post-cyclic loading reverse torque values were 25.84 Ncm (Group I) and 23.82 Ncm (Group II) respectively. Cyclic loading resulted in significantly lesser reverse torque values within both test groups (p<0.01). There was significantly greater loss of preload for Group II samples both prior to and after cyclic loading compared to Group I samples (p<0.01). Conclusion: Cyclic loading resulted in significant screw loosening within both test groups. Screw loosening was found to be significantly less for angled premachined titanium abutments than for angled custom cast Co-Cr abutments both before and after cyclic loading. The study is clinically significant regarding the importance of screw joint-abutment connection acting in a maxillary anterior implant region under load and the consequences of poor connection. The study is important in the aspect of clinical implications of angled implant abutments and the effect of loading on them.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Influence of lateral-oblique cyclic loading on abutment screw loosening of internal and external hexagon implants
    Tsuge, Takuma
    Hagiwara, Yoshiyuki
    DENTAL MATERIALS JOURNAL, 2009, 28 (04) : 373 - 381
  • [32] To determine the effect of plasma nitriding treatment 56 on screw loosening and surface topography of different 78 implant-abutment screw systems with and without thermocycling: An in vitro study
    Haokip, Nengpichong
    Tewary, Shivsagar
    Sanyal, Pronob
    Kamnoor, Shubha
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2023, 23 (03): : 285 - 293
  • [33] An abutment screw loosening study of a Diamond Like Carbon-coated CP titanium implant
    Kim, SK
    Lee, JB
    Koak, JY
    Heo, SJ
    Lee, KR
    Cho, LR
    Lee, SS
    JOURNAL OF ORAL REHABILITATION, 2005, 32 (05) : 346 - 350
  • [34] Reverse Torque Value of Angulated Screw Channel Abutment before and after Cyclic Loading: An In Vitro Study
    Chen, Yu-Hsuan
    Wu, Yu-Ling
    Chen, Hung-Shyong
    Lin, Ching-Ping
    Wu, Aaron Yu-Jen
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (03)
  • [35] Removal torque pattern of a combined cone and octalobule index implant-abutment connection at different cyclic loading: an in-vitro experimental study
    Benjaboonyazit, Kanyarin
    Chaijareenont, Pisaisit
    Khongkhunthian, Pathawee
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2019, 5 (1)
  • [36] Removal torque pattern of a combined cone and octalobule index implant-abutment connection at different cyclic loading: an in-vitro experimental study
    Kanyarin Benjaboonyazit
    Pisaisit Chaijareenont
    Pathawee Khongkhunthian
    International Journal of Implant Dentistry, 5
  • [37] In vitro assessment of PEEK and titanium implant abutments: Screw loosening and microleakage evaluations under dynamic mechanical testing
    Ortega-Martinez, Jordi
    Delgado, Luis M.
    Ortiz-Hernandez, Monica
    Punset, Miquel
    Cano-Batalla, Jordi
    Roig Cayon, Miguel
    Cabratosa-Termes, Josep
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (03): : 470 - 476
  • [38] Analysis of Dimensional Changes in the Screw and the Surface Topography at the Interface of a Titanium Screw and a Zirconia Abutment Under Cyclic Loading: An In Vitro Study
    Dhingra, Ajay
    Weiner, Saul
    Luke, Allyn C.
    Ricci, John L.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (03) : 661 - 669
  • [39] Fracture Resistance of Implant Abutments Following Abutment Alterations by Milling the Margins: An In Vitro Study
    Patankar, Anuya
    Kheur, Mohit
    Kheur, Supriya
    Lakha, Tabrez
    Burhanpurwala, Murtuza
    JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (06) : 464 - 468
  • [40] Sealing capability of implant-abutment junction under cyclic loading: a toluidine blue in vitro study
    Scarano, Antonio
    Perrotti, Vittoria
    Piattelli, Adriano
    Iaculli, Flavia
    Iezzi, Giovanna
    JOURNAL OF APPLIED BIOMATERIALS & FUNCTIONAL MATERIALS, 2015, 13 (03): : E293 - E295