Effect of Cyclic Loading on Abutment Screw Loosening in Angled Implant Abutments-An In-vitro Study

被引:3
|
作者
Ahmed, Syed Ershad [1 ]
Krishnan, Chitra Shankar [2 ]
Mohan, Jayashree [1 ]
Kalaignan, Parithimar [1 ]
机构
[1] Vinayaka Missions Sankarachariar Dent Coll, Dept Prosthodont, Salem, Tamil Nadu, India
[2] Ragas Dent Coll, Dept Prosthodont, Chennai, Tamil Nadu, India
关键词
Custom cast abutments; Preload loss; Premachined abutments; Reverse torque value; MISFIT;
D O I
10.7860/JCDR/2019/37807.12585
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Axis of loading can impact the effect of abutment fit to implant, thereby affecting the implant-abutment screw joint preload leading to screw loosening. Aim: The aim of the in-vitro study was to comparatively evaluate the effect of cyclic loading on abutment screw loosening of 25 degrees angled premachined titanium abutments with that of 25 degrees angled custom cast cobalt chromium (Co-Cr) abutments. Materials and Methods: Premachined titanium abutments (Group I) and custom cast cobalt-chromium abutments (Co-Cr) (Group II), 10 each of 25 degrees angulation were connected to their respective titanium implants mounted in stainless steel blocks. Cement-cum-screw retained nickel-chromium cast crowns were fabricated. Abutment screws were torqued to 35 Ncm. Reverse torque values were measured using digital torque meter before and after cyclic loading simulating six months of function. The results were statistically analysed using Paired t-test and Independent t-test. Results: Mean pre-cyclic loading reverse torque values were 28.96 Ncm (Group I) and 26.01 Ncm (Group II) and mean post-cyclic loading reverse torque values were 25.84 Ncm (Group I) and 23.82 Ncm (Group II) respectively. Cyclic loading resulted in significantly lesser reverse torque values within both test groups (p<0.01). There was significantly greater loss of preload for Group II samples both prior to and after cyclic loading compared to Group I samples (p<0.01). Conclusion: Cyclic loading resulted in significant screw loosening within both test groups. Screw loosening was found to be significantly less for angled premachined titanium abutments than for angled custom cast Co-Cr abutments both before and after cyclic loading. The study is clinically significant regarding the importance of screw joint-abutment connection acting in a maxillary anterior implant region under load and the consequences of poor connection. The study is important in the aspect of clinical implications of angled implant abutments and the effect of loading on them.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Implant-Abutment Misfit after Cyclic Loading: An In Vitro Experimental Study
    de Vasconcelos, John Eversong Lucena
    De Matos, Jefferson David Melo
    Queiroz, Daher Antonio
    Lopes, Guilherme da Rocha Scalzer
    De Lacerda, Bruna Caroline Goncalves Vasconcelos
    Bottino, Marco Antonio
    Turssi, Cecilia Pedroso
    Basting, Roberta Tarkany
    do Amaral, Flavia Lucisano Botelho
    Franca, Fabiana Mantovani Gomes
    MATERIALS, 2022, 15 (15)
  • [22] The Effect of Tissue Entrapment on Screw Loosening at the Implant/Abutment Interface of External- and Internal-Connection Implants: An In Vitro Study
    Zeno, Helios A.
    Buitrago, Renan L.
    Sternberger, Sidney S.
    Patt, Marisa E.
    Tovar, Nick
    Coelho, Paulo
    Kurtz, Kenneth S.
    Tuminelli, Frank J.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (03): : 216 - 223
  • [23] Abutment screw loosening in angulation-correcting implants: An in vitro study
    Hotinski, Elena
    Dudley, James
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (01): : 151 - 155
  • [24] Comparison of the Effect of Four Different Abutment Screw Torques on Screw Loosening in Single Implant-Supported Prosthesis after the Application of Mechanical Loading
    Ebadian, Behnaz
    Fathi, Amirhossein
    Khodadad, Saba
    INTERNATIONAL JOURNAL OF DENTISTRY, 2021, 2021
  • [25] In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening
    Kose, Onur Dincer
    Karatasli, Burcin
    Demircan, Sabit
    Kose, Taha Emre
    Cene, Erhan
    Aya, Serhan Aydjn
    Erdem, Mehmet Ali
    Cankaya, Abdulkadir Burak
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [26] Implant-abutment screw removal torque values between customized titanium abutment, straight titanium abutment, and hybrid zirconia abutment after a million cyclic loading: an in vitro comparative study
    Klongbunjit, Disayut
    Aunmeungtong, Weerapan
    Khongkhunthian, Pathawee
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [27] Implant-abutment screw removal torque values between customized titanium abutment, straight titanium abutment, and hybrid zirconia abutment after a million cyclic loading: an in vitro comparative study
    Disayut Klongbunjit
    Weerapan Aunmeungtong
    Pathawee Khongkhunthian
    International Journal of Implant Dentistry, 7
  • [28] Effect of Cyclic Loading on Micromotion at the Implant-Abutment Interface
    Karl, Matthias
    Taylor, Thomas D.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (06) : 1292 - 1302
  • [29] Wave analysis of implant screw loosening using an air cylindrical cyclic loading device
    Lee, J
    Kim, YS
    Kim, CW
    Han, JS
    JOURNAL OF PROSTHETIC DENTISTRY, 2002, 88 (04): : 402 - 408
  • [30] Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating
    Bacchi, Atais
    Regalin, Alexandre
    Brilhante Bhering, Claudia Lopes
    Alessandretti, Rodrigo
    Spazzin, Aloisio Oro
    JOURNAL OF ADVANCED PROSTHODONTICS, 2015, 7 (05): : 375 - 379