Effect of abutment finish lines on the mechanical behavior and marginal fit of screw-retained implant crowns: An in vitro study

被引:0
|
作者
Garcia-Gonzalez, Marta
Gonzalez-Gonzalez, Ignacio [1 ]
Garcia-Garcia, Ismael [2 ]
Blason-Gonzalez, Sergio [3 ]
Lamela-Rey, Maria Jesus [2 ]
Fernandez-Canteli, Alfonso [2 ]
Alvarez-Arenal, Angel [1 ]
机构
[1] Univ Oviedo, Sch Dent, Dept Prosthodont & Occlus, Catedrat Serrano S-N, Oviedo 33006, Spain
[2] Univ Oviedo, Dept Construct & Mfg Engn, Campus Viesques, Gijon, Spain
[3] Bundesanstalt Materialforsch & Prufung BAM, Dept Component Safety, Berlin, Germany
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2022年 / 127卷 / 02期
关键词
FRACTURE; CAD/CAM; SYSTEM; MISFIT;
D O I
10.1016/j.prosdent.2021.08.028
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The design of the implant-abutment connection has been widely researched, but the impact of different crown-abutment geometries remains unclear. Purpose. The purpose of this in vitro study was to evaluate the effect of different crown-abutment margin geometries on the mechanical behavior and fit of screw-retained implant-supported single-crown restorations by using mechanical static and fatigue tests and mastication simulation. Material and methods. A total of 45 cobalt-chromium premolar-shaped metal frameworks were fabricated for single-unit implant-supported screw-retained restorations on stock abutments and internal hexagon empty set4.25x11-mm cylindrical implants. They were divided into 3 groups according to margin geometry: S, shoulder; C, chamfer; and F, feather-edge. Three static load until fracture and 24 dynamic load tests were performed by using the International Organization for Standardization 14801:2016 standard (ISO 14801:2016) (number of cycles limit: 5x10(6) cycles, frequency: 6 Hz). The ProFatigue software program was used to optimize the procedure (S, n=12 specimens; C, n=7 specimens; and F, n=5 specimens). Six additional specimens from each group were subjected to a mastication simulation (limit number of cycles: 1x10(6) cycles, cyclic loading from P-min=30 N to P-max=300 N, frequency: 6 Hz). Results from the fatigue tests were reported descriptively, and the Fisher exact test was used to analyze the difference in failure modes. Data from maximum misfit were evaluated by photogrammetry and statistically analyzed with the Anderson-Darling test and the Kruskal-Wallis and Dunn multiple comparison tests (alpha=.05). Results. The fatigue limit was 456 N for group S, 512 N for group C, and 514 N for group F. The mean +/- standard deviation misfit was 2.6 +/- 0.1 mu m for group S, 3.8 +/- 1.1 mu m for group C, and 3.6 +/- 0.8 mu m for group F. Differences in misfit between groups S and C and between groups S and F were statistically significant (P<.05). Conclusions. Crown-abutment connections with chamfer and feather-edge margins showed better mechanical behavior, while shoulder margin exhibited better fit. However, high levels of fit were achieved for all the evaluated geometries.
引用
收藏
页码:318.e1 / 318.e10
页数:10
相关论文
共 50 条
  • [21] Effect of Abutment Screw Design and Crown/Implant Ratio on Preload Maintenance of Single-Crown Screw-Retained Implant-Supported Prostheses
    Rodrigues, Isabela
    Zanardi, Piero
    Sesma, Newton
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (06) : 1397 - 1403
  • [22] EFFECT OF DIGITIZING TECHNIQUES ON THE FIT OF IMPLANT-RETAINED CROWNS WITH DIFFERENT ANTI ROTATIONAL ABUTMENT FEATURES
    Aktas, Guliz
    Ozcan, Nihal
    Aydin, Didem Hasanoglu
    Sahin, Erdal
    Akca, Kivanc
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (05): : 367 - 372
  • [23] Effect of Engaging Abutment Position in Implant-Borne, Screw-Retained Three-Unit Fixed Cantilevered Prostheses
    Dogus, Sitki M.
    Kurtz, Kenneth S.
    Watanabe, Ikuya
    Griggs, Jason A.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (05): : 348 - 354
  • [24] Evaluation of marginal bone level, technical and biological complications between screw-retained and cement-retained all-ceramic implant-supported crowns on zirconia abutment: A systematic review and meta-analysis
    Potdukhe, Shruti S.
    Iyer, Janani M.
    Nadgere, Jyoti B.
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2024, 24 (01): : 25 - 35
  • [25] In vitro effect of load cycling on metal-ceramic cement- and screw-retained implant restorations
    Karl, Matthias
    Graef, Friedrich
    Taylor, Thomas D.
    Heckmann, Siegfried M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (03): : 137 - 140
  • [26] In vitro fit of CAD-CAM complete arch screw-retained titanium and zirconia implant prostheses fabricated on 4 implants
    AL-Meraikhi, Hadi
    Yilmaz, Burak
    McGlumphy, Edwin
    Brantley, William
    Johnston, William M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (03): : 409 - 416
  • [27] Effect of multiple firings on the marginal fit of monolithic zirconia crowns: An in vitro study
    Yang, Song
    Li, Qi
    Chen, Sheng-yuan
    Yu, Hao
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (06): : 897 - 901
  • [28] In Vitro Evaluation of Reverse Torque Value of Abutment Screw and Marginal Opening in a Screw- and Cement-Retained Implant Fixed Partial Denture Design
    Kim, Seok-Gyu
    Park, Jae-Uk
    Jeong, Jae-Heon
    Bae, Chang
    Bae, Tae-Soo
    Chee, Winston
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (06) : 1061 - 1067
  • [29] Angulated screw-retained and cemented implant crowns following flapless immediate implant placement in the aesthetic region: A 1-year prospective cohort study
    Shi, Jun-Yu
    Lv, Xiao-Lei
    Gu, Ying-Xin
    Lai, Hong-Chang
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2020, 13 (03) : 269 - 277
  • [30] Effect of primary versus secondary splinting impression techniques on the passive fit of screw-retained implant prosthesis: a randomized clinical trial
    Radwan Saleh Algabri
    Sadeq Ali Altayyar
    Hanan Omar Abo-Alrejal
    Ali Abdulghani Alsourori
    Dhafer Abdulwasea Alshaibani
    Marwa Hassan Mostafa
    Bulletin of the National Research Centre, 47 (1)