Effect of abutment finish lines on the mechanical behavior and marginal fit of screw-retained implant crowns: An in vitro study

被引:0
|
作者
Garcia-Gonzalez, Marta
Gonzalez-Gonzalez, Ignacio [1 ]
Garcia-Garcia, Ismael [2 ]
Blason-Gonzalez, Sergio [3 ]
Lamela-Rey, Maria Jesus [2 ]
Fernandez-Canteli, Alfonso [2 ]
Alvarez-Arenal, Angel [1 ]
机构
[1] Univ Oviedo, Sch Dent, Dept Prosthodont & Occlus, Catedrat Serrano S-N, Oviedo 33006, Spain
[2] Univ Oviedo, Dept Construct & Mfg Engn, Campus Viesques, Gijon, Spain
[3] Bundesanstalt Materialforsch & Prufung BAM, Dept Component Safety, Berlin, Germany
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2022年 / 127卷 / 02期
关键词
FRACTURE; CAD/CAM; SYSTEM; MISFIT;
D O I
10.1016/j.prosdent.2021.08.028
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The design of the implant-abutment connection has been widely researched, but the impact of different crown-abutment geometries remains unclear. Purpose. The purpose of this in vitro study was to evaluate the effect of different crown-abutment margin geometries on the mechanical behavior and fit of screw-retained implant-supported single-crown restorations by using mechanical static and fatigue tests and mastication simulation. Material and methods. A total of 45 cobalt-chromium premolar-shaped metal frameworks were fabricated for single-unit implant-supported screw-retained restorations on stock abutments and internal hexagon empty set4.25x11-mm cylindrical implants. They were divided into 3 groups according to margin geometry: S, shoulder; C, chamfer; and F, feather-edge. Three static load until fracture and 24 dynamic load tests were performed by using the International Organization for Standardization 14801:2016 standard (ISO 14801:2016) (number of cycles limit: 5x10(6) cycles, frequency: 6 Hz). The ProFatigue software program was used to optimize the procedure (S, n=12 specimens; C, n=7 specimens; and F, n=5 specimens). Six additional specimens from each group were subjected to a mastication simulation (limit number of cycles: 1x10(6) cycles, cyclic loading from P-min=30 N to P-max=300 N, frequency: 6 Hz). Results from the fatigue tests were reported descriptively, and the Fisher exact test was used to analyze the difference in failure modes. Data from maximum misfit were evaluated by photogrammetry and statistically analyzed with the Anderson-Darling test and the Kruskal-Wallis and Dunn multiple comparison tests (alpha=.05). Results. The fatigue limit was 456 N for group S, 512 N for group C, and 514 N for group F. The mean +/- standard deviation misfit was 2.6 +/- 0.1 mu m for group S, 3.8 +/- 1.1 mu m for group C, and 3.6 +/- 0.8 mu m for group F. Differences in misfit between groups S and C and between groups S and F were statistically significant (P<.05). Conclusions. Crown-abutment connections with chamfer and feather-edge margins showed better mechanical behavior, while shoulder margin exhibited better fit. However, high levels of fit were achieved for all the evaluated geometries.
引用
收藏
页码:318.e1 / 318.e10
页数:10
相关论文
共 50 条
  • [31] Peri-implant conditions and marginal bone loss around cemented and screw-retained single implant crowns in posterior regions: A retrospective cohort study with up to 4 years follow-up
    Shi, Jun-Yu
    Jie-Ni
    Zhuang, Long-fei
    Zhang, Xiao-Meng
    Fan, Lin-Feng
    Lai, Hong-Chang
    PLOS ONE, 2018, 13 (02):
  • [32] Stereomicroscopic Evaluation of Marginal Fit of Premachined and Castable Abutments at Implant Abutment Connection Interface - An In Vitro Study
    Kumar, Prince
    Singh, Swarndeep
    Mishra, Sunil Kumar
    JOURNAL OF THE SCIENTIFIC SOCIETY, 2023, 50 (02) : 254 - 258
  • [33] Internal fit and marginal adaptation of all-ceramic implant-supported hybrid abutment crowns with custom-milled screw-channels on Titanium-base: in-vitro study
    Fakhr, Marwa Wagih Zaky Fouad
    Alansary, Hesham
    Hassanien, Eman Ezzat Youssef
    BMC ORAL HEALTH, 2024, 24 (01):
  • [34] The Effect of a Digital Manufacturing Technique, Preparation Taper, and Finish Line Design on the Marginal Fit of Temporary Molar Crowns: An In-Vitro Study
    Mugri, Maryam H.
    Dewan, Harisha
    Sayed, Mohammed E.
    Shaabi, Fawzia Ibraheem
    Hakami, Hanan Ibrahim
    Jokhadar, Hossam F.
    Alqahtani, Nasser M.
    Alshahrani, Ahid Amer
    Alabdullah, Abdullah S.
    Alshehri, Abdullah Hasan
    Wadei, Mohammed Hussain Dafer Al
    Arif, Fatimah Yahya
    Adawi, Ebtihag H.
    Al-Makramani, Bandar M. A.
    Chohan, Hitesh
    BIOMEDICINES, 2023, 11 (02)
  • [35] Cemented versus screw-retained implant-supported single-tooth crowns: a 4-year prospective clinical study
    Vigolo, P
    Givani, A
    Majzoub, Z
    Cordioli, G
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2004, 19 (02) : 260 - 265
  • [36] Evaluation of the masking ability, marginal adaptation, and fracture resistance of screw-retained lithium disilicate implant-supported crowns cemented to titanium bases versus preparable abutments
    Kordi, Ahmad Waled Mohamad
    Salman, Abdallah Ibrahim
    Metwally, Nayrouz Adel
    Khamis, Mohamed Moataz
    BMC ORAL HEALTH, 2023, 23 (01)
  • [37] Effect of aging on the marginal fit of milled and printed zirconia crowns: an in-vitro study
    Mahmoud S. Elsayed
    Ahmed Y. El-Kouedi
    Tamer E. Shokry
    BMC Oral Health, 25 (1)
  • [38] Evaluation of the masking ability, marginal adaptation, and fracture resistance of screw-retained lithium disilicate implant-supported crowns cemented to titanium bases versus preparable abutments
    Ahmad Waled Mohamad Kordi
    Abdallah Ibrahim Salman
    Nayrouz Adel Metwally
    Mohamed Moataz Khamis
    BMC Oral Health, 23
  • [39] In vitro validation of Digital Image Analysis Sequence (DIAS) for the assessment of the marginal fit of cement-retained implant-supported experimental crowns
    Aristeidis A. Villias
    Stefanos G. Kourtis
    Hercules C. Karkazis
    Gregory L. Polyzois
    International Journal of Implant Dentistry, 7
  • [40] Marginal fit of prefabricated crowns of the Ha-Ti implant system: An in vitro scanning electron microscopic study
    Besimo, C
    Bodenschatz, V
    Guggenheim, R
    Hassell, T
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 1996, 9 (01) : 87 - 94