The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time

被引:29
|
作者
Yousefian, Peyman [1 ]
Shin, Sungtae [1 ]
Mousavi, Azin [1 ]
Kim, Chang-Sei [2 ]
Mukkamala, Ramakrishna [3 ]
Jang, Dae-Geun [4 ]
Ko, Byung-Hoon [4 ]
Lee, Jongwook [4 ]
Kwon, Ui Kun [4 ]
Kim, Youn Ho [4 ]
Hahn, Jin-Oh [1 ]
机构
[1] Univ Maryland, Dept Mech Engn, College Pk, MD 20742 USA
[2] Chonnam Natl Univ, Sch Mech Engn, Gwangju, South Korea
[3] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[4] Samsung Adv Inst Technol, Device & Syst Res Ctr, Suwon, Gyeonggi, South Korea
关键词
HEART-RATE; CARDIOVASCULAR-RESPONSE; BREATHING RATE; DECREASES; STRESS; DEVICE;
D O I
10.1038/s41598-019-46936-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The goal of this study was to investigate the potential of wearable limb ballistocardiography (BCG) to enable cuff-less blood pressure (BP) monitoring, by investigating the association between wearable limb BCG-based pulse transit time (PTT) and BP. A wearable BCG-based PTT was calculated using the BCG and photoplethysmogram (PPG) signals acquired by a wristband as proximal and distal timing reference (called the wrist PTT). Its efficacy as surrogate of BP was examined in comparison with PTT calculated using the whole-body BCG acquired by a customized weighing scale (scale PTT) as well as pulse arrival time (PAT) using the experimental data collected from 22 young healthy participants under multiple BP-perturbing interventions. The wrist PTT exhibited close association with both diastolic (group average r = 0.79; mean absolute error (MAE) = 5.1 mmHg) and systolic (group average r = 0.81; MAE= 7.6 mmHg) BP. The efficacy of the wrist PTT was superior to scale PTT and PAT for both diastolic and systolic BP. The association was consistent and robust against diverse BP-perturbing interventions. The wrist PTT showed superior association with BP when calculated with green PPG rather than infrared PPG. In sum, wearable limb BCG has the potential to realize convenient cuff-less BP monitoring via PTT.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time
    Peyman Yousefian
    Sungtae Shin
    Azin Mousavi
    Chang-Sei Kim
    Ramakrishna Mukkamala
    Dae-Geun Jang
    Byung-Hoon Ko
    Jongwook Lee
    Ui Kun Kwon
    Youn Ho Kim
    Jin-Oh Hahn
    Scientific Reports, 9
  • [2] Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring
    Kim, Chang-Sei
    Carek, Andrew M.
    Mukkamala, Ramakrishna
    Inan, Omer T.
    Hahn, Jin-Oh
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (11) : 2657 - 2664
  • [3] Wearable Continuous Blood Pressure Monitoring Devices Based on Pulse Wave Transit Time and Pulse Arrival Time: A Review
    Zhou, Zi-Bo
    Cui, Tian-Rui
    Li, Ding
    Jian, Jin-Ming
    Li, Zhen
    Ji, Shou-Rui
    Li, Xin
    Xu, Jian-Dong
    Liu, Hou-Fang
    Yang, Yi
    Ren, Tian-Ling
    MATERIALS, 2023, 16 (06)
  • [4] Wearable Cuff-Less Blood Pressure Estimation at Home via Pulse Transit Time
    Ganti, Venu G.
    Carek, Andrew M.
    Nevius, Brandi N.
    Heller, J. Alex
    Etemadi, Mozziyar
    Inan, Omer T.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (06) : 1926 - 1937
  • [5] Prototype of Wearable Device for Blood Pressure using Pulse Transit Time
    Bunkum, Manao
    Wanluk, Nutthanan
    Visitsattapongse, Sarinporn
    13TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2021), 2018,
  • [6] Pulse Transit Time-Pulse Wave Analysis Fusion Based on Wearable Wrist Ballistocardiogram for Cuff-Less Blood Pressure Trend Tracking
    Yousefian, Peyman
    Shin, Sungtae
    Mousavi, Azin Sadat
    Tivay, Ali
    Kim, Chang-Sei
    Mukkamala, Ramakrishna
    Jang, Dae-Geun
    Ko, Byung Hoon
    Lee, Jongwook
    Kwon, Ui-Kun
    Kim, Youn Ho
    Hahn, Jin-Oh
    IEEE ACCESS, 2020, 8 : 138077 - 138087
  • [7] Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice
    Mukkamala, Ramakrishna
    Hahn, Jin-Oh
    Inan, Omer T.
    Mestha, Lalit K.
    Kim, Chang-Sei
    Toreyin, Hakan
    Kyal, Survi
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (08) : 1879 - 1901
  • [8] Validation of ambulatory blood pressure monitoring and pulse transit time
    Liendo Martinez, K. H.
    Lopez-Padilla, D.
    De Miguel Diez, J.
    Villar Alvarez, F.
    Gomez Garcia, T.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [9] Development of a Wearable Pulse Transit Time Monitoring Device
    Jung, Dong-Keun
    Ha, Jeong-Seo
    Kang, Ku-Tae
    Kim, Kwang-Nyon
    Kim, Ki-Ryon
    Ye, Soo-Young
    Ro, Jung-Hoon
    Jeon, Gye-Rok
    HEALTHCARE INFORMATICS RESEARCH, 2008, 14 (03) : 295 - 302
  • [10] Photoplethysmography Derivatives and Pulse Transit Time in Overnight Blood Pressure Monitoring
    Shahrbabaki, Sobhan Salari
    Ahmed, Beena
    Penzel, Thomas
    Cvetkovic, Dean
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 2855 - 2858