The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time

被引:29
|
作者
Yousefian, Peyman [1 ]
Shin, Sungtae [1 ]
Mousavi, Azin [1 ]
Kim, Chang-Sei [2 ]
Mukkamala, Ramakrishna [3 ]
Jang, Dae-Geun [4 ]
Ko, Byung-Hoon [4 ]
Lee, Jongwook [4 ]
Kwon, Ui Kun [4 ]
Kim, Youn Ho [4 ]
Hahn, Jin-Oh [1 ]
机构
[1] Univ Maryland, Dept Mech Engn, College Pk, MD 20742 USA
[2] Chonnam Natl Univ, Sch Mech Engn, Gwangju, South Korea
[3] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[4] Samsung Adv Inst Technol, Device & Syst Res Ctr, Suwon, Gyeonggi, South Korea
关键词
HEART-RATE; CARDIOVASCULAR-RESPONSE; BREATHING RATE; DECREASES; STRESS; DEVICE;
D O I
10.1038/s41598-019-46936-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The goal of this study was to investigate the potential of wearable limb ballistocardiography (BCG) to enable cuff-less blood pressure (BP) monitoring, by investigating the association between wearable limb BCG-based pulse transit time (PTT) and BP. A wearable BCG-based PTT was calculated using the BCG and photoplethysmogram (PPG) signals acquired by a wristband as proximal and distal timing reference (called the wrist PTT). Its efficacy as surrogate of BP was examined in comparison with PTT calculated using the whole-body BCG acquired by a customized weighing scale (scale PTT) as well as pulse arrival time (PAT) using the experimental data collected from 22 young healthy participants under multiple BP-perturbing interventions. The wrist PTT exhibited close association with both diastolic (group average r = 0.79; mean absolute error (MAE) = 5.1 mmHg) and systolic (group average r = 0.81; MAE= 7.6 mmHg) BP. The efficacy of the wrist PTT was superior to scale PTT and PAT for both diastolic and systolic BP. The association was consistent and robust against diverse BP-perturbing interventions. The wrist PTT showed superior association with BP when calculated with green PPG rather than infrared PPG. In sum, wearable limb BCG has the potential to realize convenient cuff-less BP monitoring via PTT.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Blood pressure monitoring during exercise: Comparison of pulse transit time and volume clamp methods
    Wibmer, Thomas
    Denner, Coy
    Fischer, Christoph
    Schildge, Benedikt
    Ruediger, Stefan
    Kropf-Sanchen, Cornelia
    Rottbauer, Wolfgang
    Schumann, Christian
    BLOOD PRESSURE, 2015, 24 (06) : 353 - 360
  • [22] Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Predictions on Maximum Calibration Period and Acceptable Error Limits
    Mukkamala, Ramakrishna
    Hahn, Jin-Oh
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (06) : 1410 - 1420
  • [23] Development of a Continuous Blood Pressure Monitoring System based on Pulse Transit Time and Hemodynamic Covariates
    Zhang, Yiming
    Zhou, Congcong
    Huang, Zhongyi
    Ye, Xuesong
    BIODEVICES: PROCEEDINGS OF THE 13TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES, VOL 1: BIODEVICES, 2020, 2020, : 33 - 39
  • [24] Continuous blood pressure monitoring during exercise using pulse wave transit time measurement
    Lass, J
    Meigas, K
    Karai, D
    Kattai, R
    Kaik, J
    Rossmann, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2239 - 2242
  • [25] Wearable Pulse Wave Sensor and Interface for Real-Time Dynamic Blood Pressure Monitoring
    Li, Huimin
    Li, Anqi
    Zhou, Zhongyi
    Jiang, Bowei
    Yang, Qi
    Liu, Xinghui
    Wang, Kai
    2021 IEEE INTERNATIONAL ELECTRON DEVICES MEETING (IEDM), 2021,
  • [26] Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure
    Zhang, Guanqun
    Gao, Mingwu
    Xu, Da
    Olivier, N. Bari
    Mukkamala, Ramakrishna
    JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (06) : 1681 - 1686
  • [27] Pulse transit time ratio as a potential marker for paediatric crural and brachial blood pressure index
    J Y A Foo
    C S Lim
    S J Wilson
    G R Williams
    M-A Harris
    D M Cooper
    Journal of Human Hypertension, 2007, 21 : 415 - 417
  • [28] Pulse transit time ratio as a potential marker for paediatric crural and brachial blood pressure index
    Foo, J. Y. A.
    Lim, C. S.
    Wilson, S. J.
    Williams, G. R.
    Harris, M-A
    Cooper, D. M.
    JOURNAL OF HUMAN HYPERTENSION, 2007, 21 (05) : 415 - 417
  • [29] Evaluation of the Correlation Between Blood Pressure and Pulse Transit Time
    He, Xiaochuan
    Goubran, Rafik A.
    Liu, Xiaoping P.
    2013 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS PROCEEDINGS (MEMEA), 2013, : 17 - 20
  • [30] A Compensation Method for Blood Pressure Estimation by Pulse Transit Time
    Liu, Songsong
    Ma, Heather T.
    Chen, Long
    Wang, Xiaopeng
    Yuan, Dezhang
    2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,