The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time

被引:29
|
作者
Yousefian, Peyman [1 ]
Shin, Sungtae [1 ]
Mousavi, Azin [1 ]
Kim, Chang-Sei [2 ]
Mukkamala, Ramakrishna [3 ]
Jang, Dae-Geun [4 ]
Ko, Byung-Hoon [4 ]
Lee, Jongwook [4 ]
Kwon, Ui Kun [4 ]
Kim, Youn Ho [4 ]
Hahn, Jin-Oh [1 ]
机构
[1] Univ Maryland, Dept Mech Engn, College Pk, MD 20742 USA
[2] Chonnam Natl Univ, Sch Mech Engn, Gwangju, South Korea
[3] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[4] Samsung Adv Inst Technol, Device & Syst Res Ctr, Suwon, Gyeonggi, South Korea
关键词
HEART-RATE; CARDIOVASCULAR-RESPONSE; BREATHING RATE; DECREASES; STRESS; DEVICE;
D O I
10.1038/s41598-019-46936-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The goal of this study was to investigate the potential of wearable limb ballistocardiography (BCG) to enable cuff-less blood pressure (BP) monitoring, by investigating the association between wearable limb BCG-based pulse transit time (PTT) and BP. A wearable BCG-based PTT was calculated using the BCG and photoplethysmogram (PPG) signals acquired by a wristband as proximal and distal timing reference (called the wrist PTT). Its efficacy as surrogate of BP was examined in comparison with PTT calculated using the whole-body BCG acquired by a customized weighing scale (scale PTT) as well as pulse arrival time (PAT) using the experimental data collected from 22 young healthy participants under multiple BP-perturbing interventions. The wrist PTT exhibited close association with both diastolic (group average r = 0.79; mean absolute error (MAE) = 5.1 mmHg) and systolic (group average r = 0.81; MAE= 7.6 mmHg) BP. The efficacy of the wrist PTT was superior to scale PTT and PAT for both diastolic and systolic BP. The association was consistent and robust against diverse BP-perturbing interventions. The wrist PTT showed superior association with BP when calculated with green PPG rather than infrared PPG. In sum, wearable limb BCG has the potential to realize convenient cuff-less BP monitoring via PTT.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] PULSE TRANSIT-TIME - RELATIONSHIP TO BLOOD-PRESSURE
    OBRIST, PA
    LIGHT, KC
    MCCUBBIN, JA
    HUTCHESON, JS
    HOFFER, JL
    BEHAVIOR RESEARCH METHODS & INSTRUMENTATION, 1978, 10 (05): : 623 - 626
  • [32] Continuous Noninvasive blood pressure measurement by pulse transit time
    Fung, P
    Dumont, G
    Ries, C
    Mott, C
    Ansermino, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 738 - 741
  • [33] Blood Pressure Estimation Based on Pulse Transit Time with LANDMARC
    Wang, Yang
    Liu, Zhiwen
    2017 IEEE LIFE SCIENCES CONFERENCE (LSC), 2017, : 141 - 144
  • [34] Blood Pressure - Pulse Transit Time Relationships: Comparative Studies
    Polinski, Artur
    Bujnowski, Adam
    Kocejko, Tomasz
    Wtorek, Jerzy
    2020 13TH INTERNATIONAL CONFERENCE ON HUMAN SYSTEM INTERACTION (HSI), 2020, : 289 - 294
  • [35] Correlation Study Between Blood Pressure And Pulse Transit Time
    Pereira, T.
    Sanches, R.
    Reis, P.
    Pego, J.
    Simoes, R.
    2015 IEEE 4TH PORTUGUESE MEETING ON BIOENGINEERING (ENBENG), 2015,
  • [36] Piezoelectric Dynamics of Arterial Pulse for Wearable Continuous Blood Pressure Monitoring
    Yi, Zhiran
    Liu, Zhaoxu
    Li, Wenbo
    Ruan, Tao
    Chen, Xiang
    Liu, Jingquan
    Yang, Bin
    Zhang, Wenming
    ADVANCED MATERIALS, 2022, 34 (16)
  • [37] A flexible multimodal pulse sensor for wearable continuous blood pressure monitoring
    Tian, Shuo
    Wang, Liangqi
    Zhu, Rong
    MATERIALS HORIZONS, 2024, 11 (10) : 2428 - 2437
  • [38] Posture-Dependent Variability in Wrist Ballistocardiogram-Photoplethysmogram Pulse Transit Time: Implication to Cuff-Less Blood Pressure Tracking
    Shin, Sungtae
    Mousavi, Azin
    Lyle, Sophia
    Jang, Elisabeth
    Yousefian, Peyman
    Mukkamala, Ramakrishna
    Jang, Dae-Geun
    Kwon, Ui Kun
    Kim, Youn Ho
    Hahn, Jin-Oh
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (01) : 347 - 355
  • [39] Camera-Based Blood Pressure Monitoring Based on Multisite and Multiwavelength Pulse Transit Time Features
    Huang, Yukai
    Huang, Dongmin
    Huang, Jia
    Wang, Guowei
    Pan, Liping
    Lu, Hongzhou
    He, Min
    Wang, Wenjin
    IEEE Transactions on Instrumentation and Measurement, 2024, 73
  • [40] Cuff-Less Continuous Blood Pressure Monitoring System Using Pulse Transit Time Techniques
    Zaki, Wan Suhaimizan Wan
    Correia, Ricardo
    Korposh, Serhiy
    Hayes-Gill, Barrie R.
    Morgan, Stephen P.
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2016, 8 (01): : 51 - 57