The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time

被引:29
|
作者
Yousefian, Peyman [1 ]
Shin, Sungtae [1 ]
Mousavi, Azin [1 ]
Kim, Chang-Sei [2 ]
Mukkamala, Ramakrishna [3 ]
Jang, Dae-Geun [4 ]
Ko, Byung-Hoon [4 ]
Lee, Jongwook [4 ]
Kwon, Ui Kun [4 ]
Kim, Youn Ho [4 ]
Hahn, Jin-Oh [1 ]
机构
[1] Univ Maryland, Dept Mech Engn, College Pk, MD 20742 USA
[2] Chonnam Natl Univ, Sch Mech Engn, Gwangju, South Korea
[3] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[4] Samsung Adv Inst Technol, Device & Syst Res Ctr, Suwon, Gyeonggi, South Korea
关键词
HEART-RATE; CARDIOVASCULAR-RESPONSE; BREATHING RATE; DECREASES; STRESS; DEVICE;
D O I
10.1038/s41598-019-46936-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The goal of this study was to investigate the potential of wearable limb ballistocardiography (BCG) to enable cuff-less blood pressure (BP) monitoring, by investigating the association between wearable limb BCG-based pulse transit time (PTT) and BP. A wearable BCG-based PTT was calculated using the BCG and photoplethysmogram (PPG) signals acquired by a wristband as proximal and distal timing reference (called the wrist PTT). Its efficacy as surrogate of BP was examined in comparison with PTT calculated using the whole-body BCG acquired by a customized weighing scale (scale PTT) as well as pulse arrival time (PAT) using the experimental data collected from 22 young healthy participants under multiple BP-perturbing interventions. The wrist PTT exhibited close association with both diastolic (group average r = 0.79; mean absolute error (MAE) = 5.1 mmHg) and systolic (group average r = 0.81; MAE= 7.6 mmHg) BP. The efficacy of the wrist PTT was superior to scale PTT and PAT for both diastolic and systolic BP. The association was consistent and robust against diverse BP-perturbing interventions. The wrist PTT showed superior association with BP when calculated with green PPG rather than infrared PPG. In sum, wearable limb BCG has the potential to realize convenient cuff-less BP monitoring via PTT.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Camera Wavelength Selection for Multi-wavelength Pulse Transit Time based Blood Pressure Monitoring
    Huang, Yukai
    Huang, Dongmin
    Huang, Jia
    Lu, Hongzhou
    He, Min
    Wang, Wenjin
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [42] Pulse Transit Time and Pulse Width as Potential Measure for Estimating Beat-to-Beat Systolic and Diastolic Blood Pressure
    Arza, Adriana
    Lazaro, Jesus
    Gil, Eduardo
    Laguna, Pablo
    Aguilo, Jordi
    Bailon, Raquel
    2013 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2013, 40 : 887 - 890
  • [43] Comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference
    Gao, Mingwu
    Olivier, N. Bari
    Mukkamala, Ramakrishna
    PHYSIOLOGICAL REPORTS, 2016, 4 (10):
  • [44] Novel blood pressure and pulse pressure estimation based on pulse transit time and stroke volume approximation
    Joonnyong Lee
    JangJay Sohn
    Jonghyun Park
    SeungMan Yang
    Saram Lee
    Hee Chan Kim
    BioMedical Engineering OnLine, 17
  • [45] Pulse Wave Transit Time and Its Relationship with Systolic Blood Pressure
    Zakaria, N. A.
    Sharifmuddin, N. B.
    Ridzwan, W. M. F. Wan Mohd.
    Mahmood, N. H.
    6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 1354 - +
  • [46] An implantable optical blood pressure sensor based on pulse transit time
    Fiala, Jens
    Bingger, Philipp
    Ruh, Dominic
    Foerster, Katharina
    Heilmann, Claudia
    Beyersdorf, Friedhelm
    Zappe, Hans
    Seifert, Andreas
    BIOMEDICAL MICRODEVICES, 2013, 15 (01) : 73 - 81
  • [47] Novel blood pressure and pulse pressure estimation based on pulse transit time and stroke volume approximation
    Lee, Joonnyong
    Sohn, JangJay
    Park, Jonghyun
    Yang, SeungMan
    Lee, Saram
    Kim, Hee Chan
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [48] THE RELATIONSHIP BETWEEN PULSE TRANSIT-TIME AND BLOOD-PRESSURE
    MARIE, GV
    LO, CR
    JOHNSTON, DW
    BIOLOGICAL PSYCHOLOGY, 1980, 11 (3-4) : 298 - 298
  • [49] Noninvasive Continuous Blood Pressure Estimation with Peripheral Pulse Transit Time
    Li, Yibin
    Chen, Xiaomeng
    Zhang, Yang
    Deng, Ning
    PROCEEDINGS OF 2016 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2016, : 66 - 69
  • [50] Measuring blood pressure by a cuffless device using the pulse transit time
    Patzak, Andreas