Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring

被引:99
|
作者
Kim, Chang-Sei [1 ]
Carek, Andrew M. [2 ]
Mukkamala, Ramakrishna [3 ]
Inan, Omer T. [2 ]
Hahn, Jin-Oh [1 ]
机构
[1] Univ Maryland, Dept Mech Engn, College Pk, MD 20742 USA
[2] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[3] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
基金
美国国家卫生研究院;
关键词
Ballistocardiogram (BCG); blood pressure; electrocardiogram (ECG); pulse arrival time (PAT); pulse transit time (PTT); ARRIVAL-TIME; PREEJECTION PERIOD; HEART-RATE; CONTRACTILITY; CALIBRATION; MARKER; ECG;
D O I
10.1109/TBME.2015.2440291
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Goal: We tested the hypothesis that the ballistocardiogram (BCG) waveform could yield a viable proximal timing reference for measuring pulse transit time (PTT). Methods: From 15 healthy volunteers, we measured PTT as the time interval between BCG and a noninvasively measured finger blood pressure (BP) waveform. To evaluate the efficacy of the BCG-based PTT in estimating BP, we likewise measured pulse arrival time (PAT) using the electrocardiogram (ECG) as proximal timing reference and compared their correlations to BP. Results: BCG-based PTT was correlated with BP reasonably well: the mean correlation coefficient (r) was 0.62 for diastolic (DP), 0.65 for mean (MP), and 0.66 for systolic (SP) pressures when the intersecting tangent method was used as distal timing reference. Comparing four distal timing references (intersecting tangent, maximum second derivative, diastolic minimum, and systolic maximum), PTT exhibited the best correlation with BP when the systolic maximum method was used (mean r value was 0.66 for DP, 0.67 for MP, and 0.70 for SP). PTT was more strongly correlated with DP than PAT regardless of the distal timing reference: mean r value was 0.62 versus 0.51 (p = 0.07) for intersecting tangent, 0.54 versus 0.49 (p = 0.17) for maximum second derivative, 0.58 versus 0.52 (p = 0.37) for diastolic minimum, and 0.66 versus 0.60 (p = 0.10) for systolic maximum methods. The difference between PTT and PAT in estimating DP was significant (p = 0.01) when the r values associated with all the distal timing references were compared altogether. However, PAT appeared to outperform PTT in estimating SP (p = 0.31 when the r values associated with all the distal timing references were compared altogether). Conclusion: We conclude that BCG is an adequate proximal timing reference in deriving PTT, and that BCG-based PTT may be superior to ECG-based PAT in estimating DP. Significance: PTT with BCG as proximal timing reference has potential to enable convenient and ubiquitous cuffless BP monitoring.
引用
收藏
页码:2657 / 2664
页数:8
相关论文
共 50 条
  • [1] The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time
    Yousefian, Peyman
    Shin, Sungtae
    Mousavi, Azin
    Kim, Chang-Sei
    Mukkamala, Ramakrishna
    Jang, Dae-Geun
    Ko, Byung-Hoon
    Lee, Jongwook
    Kwon, Ui Kun
    Kim, Youn Ho
    Hahn, Jin-Oh
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [2] The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time
    Peyman Yousefian
    Sungtae Shin
    Azin Mousavi
    Chang-Sei Kim
    Ramakrishna Mukkamala
    Dae-Geun Jang
    Byung-Hoon Ko
    Jongwook Lee
    Ui Kun Kwon
    Youn Ho Kim
    Jin-Oh Hahn
    Scientific Reports, 9
  • [3] Design and Development of Pulse Transit Time Based Cuffless Blood Pressure Monitoring System
    Singh, Harinderjit
    Singh, Mandeep
    2015 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, SIGNALS, COMMUNICATION AND OPTIMIZATION (EESCO), 2015,
  • [4] Noninvasive Cuffless Blood Pressure Measurement by Vascular Transit Time
    Shukla, Satya Narayan
    Kakwani, Karan
    Patra, Amit
    Lahkar, Bipin Kumar
    Gupta, Vivek Kumar
    Jayakrishna, Alwar
    Vashisht, Puneet
    Sreekanth, Induja
    2015 28TH INTERNATIONAL CONFERENCE ON VLSI DESIGN (VLSID), 2015, : 535 - 540
  • [5] Pulse transit time technique for cuffless unobtrusive blood pressure measurement: from theory to algorithm
    Xiaorong Ding
    Yuan-Ting Zhang
    Biomedical Engineering Letters, 2019, 9 : 37 - 52
  • [6] Pulse transit time technique for cuffless unobtrusive blood pressure measurement: from theory to algorithm
    Ding, Xiaorong
    Zhang, Yuan-Ting
    BIOMEDICAL ENGINEERING LETTERS, 2019, 9 (01) : 37 - 52
  • [7] Measuring blood pressure by a cuffless device using the pulse transit time
    Patzak, Andreas
    INTERNATIONAL JOURNAL CARDIOLOGY HYPERTENSION, 2021, 8
  • [8] Live Demonstration: Pulse Transit Time Measurement on a Modified Weighing Scale for Cuffless Blood Pressure Estimation
    Carek, Andrew M.
    Conant, Jordan
    Inan, Omer T.
    2016 IEEE SENSORS, 2016,
  • [9] A Calibration Method for Cuffless Continuous Blood Pressure Measurement using Gaussian Normalized Pulse Transit Time
    Xu, Yang
    Zhang, Weigong
    Wang, Dong
    Ping, Peng
    2018 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC): DISCOVERING NEW HORIZONS IN INSTRUMENTATION AND MEASUREMENT, 2018, : 152 - 156
  • [10] Continuous Cuffless Blood Pressure Estimation Based on Pulse Transit Time: A New Evaluation with Invasive BP Reference
    Tang, Zunyi
    Chen, Ying
    Liu, Shing-Hong
    Kobayashi, Toshio
    Chen, Wenxi
    2019 IEEE 10TH INTERNATIONAL CONFERENCE ON AWARENESS SCIENCE AND TECHNOLOGY (ICAST 2019), 2019, : 516 - 520