Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring

被引:99
|
作者
Kim, Chang-Sei [1 ]
Carek, Andrew M. [2 ]
Mukkamala, Ramakrishna [3 ]
Inan, Omer T. [2 ]
Hahn, Jin-Oh [1 ]
机构
[1] Univ Maryland, Dept Mech Engn, College Pk, MD 20742 USA
[2] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[3] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
基金
美国国家卫生研究院;
关键词
Ballistocardiogram (BCG); blood pressure; electrocardiogram (ECG); pulse arrival time (PAT); pulse transit time (PTT); ARRIVAL-TIME; PREEJECTION PERIOD; HEART-RATE; CONTRACTILITY; CALIBRATION; MARKER; ECG;
D O I
10.1109/TBME.2015.2440291
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Goal: We tested the hypothesis that the ballistocardiogram (BCG) waveform could yield a viable proximal timing reference for measuring pulse transit time (PTT). Methods: From 15 healthy volunteers, we measured PTT as the time interval between BCG and a noninvasively measured finger blood pressure (BP) waveform. To evaluate the efficacy of the BCG-based PTT in estimating BP, we likewise measured pulse arrival time (PAT) using the electrocardiogram (ECG) as proximal timing reference and compared their correlations to BP. Results: BCG-based PTT was correlated with BP reasonably well: the mean correlation coefficient (r) was 0.62 for diastolic (DP), 0.65 for mean (MP), and 0.66 for systolic (SP) pressures when the intersecting tangent method was used as distal timing reference. Comparing four distal timing references (intersecting tangent, maximum second derivative, diastolic minimum, and systolic maximum), PTT exhibited the best correlation with BP when the systolic maximum method was used (mean r value was 0.66 for DP, 0.67 for MP, and 0.70 for SP). PTT was more strongly correlated with DP than PAT regardless of the distal timing reference: mean r value was 0.62 versus 0.51 (p = 0.07) for intersecting tangent, 0.54 versus 0.49 (p = 0.17) for maximum second derivative, 0.58 versus 0.52 (p = 0.37) for diastolic minimum, and 0.66 versus 0.60 (p = 0.10) for systolic maximum methods. The difference between PTT and PAT in estimating DP was significant (p = 0.01) when the r values associated with all the distal timing references were compared altogether. However, PAT appeared to outperform PTT in estimating SP (p = 0.31 when the r values associated with all the distal timing references were compared altogether). Conclusion: We conclude that BCG is an adequate proximal timing reference in deriving PTT, and that BCG-based PTT may be superior to ECG-based PAT in estimating DP. Significance: PTT with BCG as proximal timing reference has potential to enable convenient and ubiquitous cuffless BP monitoring.
引用
收藏
页码:2657 / 2664
页数:8
相关论文
共 50 条
  • [21] Validation of ambulatory blood pressure monitoring and pulse transit time
    Liendo Martinez, K. H.
    Lopez-Padilla, D.
    De Miguel Diez, J.
    Villar Alvarez, F.
    Gomez Garcia, T.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [22] Continuous Noninvasive blood pressure measurement by pulse transit time
    Fung, P
    Dumont, G
    Ries, C
    Mott, C
    Ansermino, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 738 - 741
  • [23] Continuous blood pressure monitoring during exercise using pulse wave transit time measurement
    Lass, J
    Meigas, K
    Karai, D
    Kattai, R
    Kaik, J
    Rossmann, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2239 - 2242
  • [24] Noninvasive cuffless blood pressure estimation using pulse transit time and Hilbert-Huang transform
    Choi, Younhee
    Zhang, Qiao
    Ko, Seokbum
    COMPUTERS & ELECTRICAL ENGINEERING, 2013, 39 (01) : 103 - 111
  • [25] Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation
    Xiaorong Ding
    Bryan P. Yan
    Yuan-Ting Zhang
    Jing Liu
    Ni Zhao
    Hon Ki Tsang
    Scientific Reports, 7
  • [26] Continuous blood pressure measurement based on pulse transit time: a comparison to ambulatory blood pressure measurement
    Kuechler, G.
    Gehring, J.
    Wesely, M.
    Thimel, K.
    Haberl, R.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1267 - 1267
  • [27] Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation
    Ding, Xiaorong
    Yan, Bryan P.
    Zhang, Yuan-Ting
    Liu, Jing
    Zhao, Ni
    Tsang, Hon Ki
    SCIENTIFIC REPORTS, 2017, 7
  • [28] Photoplethysmography Derivatives and Pulse Transit Time in Overnight Blood Pressure Monitoring
    Shahrbabaki, Sobhan Salari
    Ahmed, Beena
    Penzel, Thomas
    Cvetkovic, Dean
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 2855 - 2858
  • [29] Comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference
    Gao, Mingwu
    Olivier, N. Bari
    Mukkamala, Ramakrishna
    PHYSIOLOGICAL REPORTS, 2016, 4 (10):
  • [30] Noninvasive cuffless blood pressure estimation using pulse transit time,Womersley number, and photoplethysmogram intensity ratio
    Thambiraj, Geerthy
    Gandhi, Uma
    Devanand, Viji
    Mangalanathan, Umapathy
    PHYSIOLOGICAL MEASUREMENT, 2019, 40 (07)