Prototype of Wearable Device for Blood Pressure using Pulse Transit Time

被引:0
|
作者
Bunkum, Manao [1 ]
Wanluk, Nutthanan [1 ]
Visitsattapongse, Sarinporn [1 ]
机构
[1] King Mongkuts Inst Technol Ladkrabang, Sch Engn, Dept Biomed Engn, Bangkok, Thailand
关键词
Blood Pressure; Wearable Device; Pulse Transit Time;
D O I
10.1109/BMEiCON53485.2021.9745229
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
At present, there is a continuous increase in the number of patients suffering from hypertension in Thailand. and resulted in higher mortality rates as well. with an increasing trend every year Some people with high blood pressure need medication and regular monitoring of their blood pressure to prevent further complications. Most of these are pressure gauges that require a cuff that is wrapped around a patient's upper arm, wrist, or thigh. which is not convenient to carry for patients who need to measure blood pressure regularly This research proposes a prototype of a wearable device for measuring blood pressure using Pulse Transit Time (PTT) by measuring the pulse between the wrist and the index finger of the other hand. and take the pulse movement time to calculate the blood pressure Based on the results of testing prototypes of wearable devices for measuring pressure compared to commercially available pressure gauges. Of the five participants, the prototype of a wearable device for measuring pressure was approximately 94% accurate compared to commercially available pressure gauges. The prototype device can measure blood pressure in real time and is always portable.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Measuring blood pressure by a cuffless device using the pulse transit time
    Patzak, Andreas
    INTERNATIONAL JOURNAL CARDIOLOGY HYPERTENSION, 2021, 8
  • [2] Effects of Pulse Transit Time and Physiological Differences on Wearable Device based Blood Pressure Estimation
    Hsiao, Chun-Chieh
    Kuo, Hui-Chia
    Lee, Ren-Guey
    Lin, Robert
    2016 INTERNATIONAL AUTOMATIC CONTROL CONFERENCE (CACS), 2016, : 242 - 246
  • [3] Development of a Wearable Pulse Transit Time Monitoring Device
    Jung, Dong-Keun
    Ha, Jeong-Seo
    Kang, Ku-Tae
    Kim, Kwang-Nyon
    Kim, Ki-Ryon
    Ye, Soo-Young
    Ro, Jung-Hoon
    Jeon, Gye-Rok
    HEALTHCARE INFORMATICS RESEARCH, 2008, 14 (03) : 295 - 302
  • [4] The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time
    Peyman Yousefian
    Sungtae Shin
    Azin Mousavi
    Chang-Sei Kim
    Ramakrishna Mukkamala
    Dae-Geun Jang
    Byung-Hoon Ko
    Jongwook Lee
    Ui Kun Kwon
    Youn Ho Kim
    Jin-Oh Hahn
    Scientific Reports, 9
  • [5] The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time
    Yousefian, Peyman
    Shin, Sungtae
    Mousavi, Azin
    Kim, Chang-Sei
    Mukkamala, Ramakrishna
    Jang, Dae-Geun
    Ko, Byung-Hoon
    Lee, Jongwook
    Kwon, Ui Kun
    Kim, Youn Ho
    Hahn, Jin-Oh
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [6] Wearable Continuous Blood Pressure Monitoring Devices Based on Pulse Wave Transit Time and Pulse Arrival Time: A Review
    Zhou, Zi-Bo
    Cui, Tian-Rui
    Li, Ding
    Jian, Jin-Ming
    Li, Zhen
    Ji, Shou-Rui
    Li, Xin
    Xu, Jian-Dong
    Liu, Hou-Fang
    Yang, Yi
    Ren, Tian-Ling
    MATERIALS, 2023, 16 (06)
  • [7] 24-HOUR AMBULATORY BLOOD PRESSURE MEASUREMENT USING A PULSE ARRIVAL TIME BASED BLOOD PRESSURE MODEL BY A PROTOTYPE WEARABLE SENSOR
    Heimark, Sondre
    Hove, Christine
    Stepanov, Alexey
    Boysen, Elin Sundby
    Gloersen, Oyvind
    Botke-Rasmussen, Kasper Gade
    Gravdal, Hans Jacob
    Narayanapillai, Kesi
    Larstorp, Anne Cecilie K.
    Seeberg, Trine M.
    Waldum-Grevbo, Bard
    JOURNAL OF HYPERTENSION, 2023, 41 : E248 - E248
  • [8] Wearable Cuff-Less Blood Pressure Estimation at Home via Pulse Transit Time
    Ganti, Venu G.
    Carek, Andrew M.
    Nevius, Brandi N.
    Heller, J. Alex
    Etemadi, Mozziyar
    Inan, Omer T.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (06) : 1926 - 1937
  • [9] Estimation of Blood Pressure and Pulse Transit Time Using Your Smartphone
    Dias Junior, Alair
    Murali, Srinivasan
    Rincon, Francisco
    Atienza, David
    2015 EUROMICRO CONFERENCE ON DIGITAL SYSTEM DESIGN (DSD), 2015, : 173 - 180
  • [10] Motion Based Adaptive Calibration of Pulse Transit Time Measurements to Arterial Blood Pressure for an Autonomous, Wearable Blood Pressure Monitor
    McCombie, Devin B.
    Reisner, Andrew T.
    Asada, H. Harry
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 989 - +