Prototype of Wearable Device for Blood Pressure using Pulse Transit Time

被引:0
|
作者
Bunkum, Manao [1 ]
Wanluk, Nutthanan [1 ]
Visitsattapongse, Sarinporn [1 ]
机构
[1] King Mongkuts Inst Technol Ladkrabang, Sch Engn, Dept Biomed Engn, Bangkok, Thailand
关键词
Blood Pressure; Wearable Device; Pulse Transit Time;
D O I
10.1109/BMEiCON53485.2021.9745229
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
At present, there is a continuous increase in the number of patients suffering from hypertension in Thailand. and resulted in higher mortality rates as well. with an increasing trend every year Some people with high blood pressure need medication and regular monitoring of their blood pressure to prevent further complications. Most of these are pressure gauges that require a cuff that is wrapped around a patient's upper arm, wrist, or thigh. which is not convenient to carry for patients who need to measure blood pressure regularly This research proposes a prototype of a wearable device for measuring blood pressure using Pulse Transit Time (PTT) by measuring the pulse between the wrist and the index finger of the other hand. and take the pulse movement time to calculate the blood pressure Based on the results of testing prototypes of wearable devices for measuring pressure compared to commercially available pressure gauges. Of the five participants, the prototype of a wearable device for measuring pressure was approximately 94% accurate compared to commercially available pressure gauges. The prototype device can measure blood pressure in real time and is always portable.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] A Compensation Method for Blood Pressure Estimation by Pulse Transit Time
    Liu, Songsong
    Ma, Heather T.
    Chen, Long
    Wang, Xiaopeng
    Yuan, Dezhang
    2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,
  • [22] PULSE TRANSIT-TIME - RELATIONSHIP TO BLOOD-PRESSURE
    OBRIST, PA
    LIGHT, KC
    MCCUBBIN, JA
    HUTCHESON, JS
    HOFFER, JL
    BEHAVIOR RESEARCH METHODS & INSTRUMENTATION, 1978, 10 (05): : 623 - 626
  • [23] Continuous Noninvasive blood pressure measurement by pulse transit time
    Fung, P
    Dumont, G
    Ries, C
    Mott, C
    Ansermino, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 738 - 741
  • [24] Blood Pressure Estimation Based on Pulse Transit Time with LANDMARC
    Wang, Yang
    Liu, Zhiwen
    2017 IEEE LIFE SCIENCES CONFERENCE (LSC), 2017, : 141 - 144
  • [25] Blood Pressure - Pulse Transit Time Relationships: Comparative Studies
    Polinski, Artur
    Bujnowski, Adam
    Kocejko, Tomasz
    Wtorek, Jerzy
    2020 13TH INTERNATIONAL CONFERENCE ON HUMAN SYSTEM INTERACTION (HSI), 2020, : 289 - 294
  • [26] Correlation Study Between Blood Pressure And Pulse Transit Time
    Pereira, T.
    Sanches, R.
    Reis, P.
    Pego, J.
    Simoes, R.
    2015 IEEE 4TH PORTUGUESE MEETING ON BIOENGINEERING (ENBENG), 2015,
  • [27] A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time
    Buxi, Dilpreet
    Redoute, Jean-Michel
    Yuce, Mehmet Rasit
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (03) : R1 - R26
  • [28] Noninvasive Cuffless Blood Pressure Estimation Using Pulse Transit Time and Impedance Plethysmography
    Toan Huu Huynh
    Jafari, Roozbeh
    Chung, Wan-Young
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (04) : 967 - 976
  • [29] Estimation of pulse transit time using two diametric blood pressure waveform measurements
    Hahn, Jin-Oh
    Reisner, Andrew T.
    Asada, H. Harry
    MEDICAL ENGINEERING & PHYSICS, 2010, 32 (07) : 753 - 759
  • [30] Optimizing Non-Invasive Blood Pressure Estimation Using Pulse Transit Time
    Jeong, In Cheol
    Finkelstein, Joseph
    MEDINFO 2013: PROCEEDINGS OF THE 14TH WORLD CONGRESS ON MEDICAL AND HEALTH INFORMATICS, PTS 1 AND 2, 2013, 192 : 1198 - 1198