Accuracy of Implant Level Intraoral Scanning and Photogrammetry Impression Techniques in a Complete Arch with Angled and Parallel Implants: An In Vitro Study

被引:4
|
作者
Tohme, Hani [1 ]
Lawand, Ghida [2 ]
Eid, Rita [3 ]
Ahmed, Khaled E. [4 ]
Salameh, Ziad [5 ]
Makzoume, Joseph [1 ]
机构
[1] St Joseph Univ, Dept Removable Prosthodont, Fac Dent Med, Beirut 1107, Lebanon
[2] St Joseph Univ, Dept Prosthodont & Esthet Dent, Fac Dent Med, Beirut 1107, Lebanon
[3] Lebanese Univ, Fac Dent Med, Dept Prosthodont, Beirut 1107, Lebanon
[4] Griffith Univ, Sch Med & Dent, Gold Coast 4000, Australia
[5] Lebanese Univ, Fac Dent Med, Beirut 1107, Lebanon
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 21期
关键词
angulated implants; implant supported prosthesis; intraoral scanning; photogrammetry; DIGITAL IMPRESSIONS; MULTIPLE IMPLANTS; TECHNOLOGY; REHABILITATION; PLACEMENT; SYSTEM;
D O I
10.3390/app11219859
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
(1) Background: Stereophotogrammetry has recently been investigated showing high accuracy in complete implant supported cases but has scarcely been investigated in cases of tilted implants. The aim of this in vitro study was to compare the accuracy of digital impression techniques (intraoral scanning and photogrammetry) at the level of intraoral scan bodies in terms of angular deviations and 3D discrepancies. (2) Methods: A stone master cast representing an edentulous maxilla using four implant analogs was fabricated. The two anterior implants were parallel to each other, and the two posterior implants were at an angulation of 17 degrees. Digital intraoral scanning (DIOS) impressions were taken after connecting implant level scan bodies to the master cast and STL files were exported (n = 15). Digital photogrammetry (DPG) impressions were captured using a PiC Camera after tightening implant level PiC optical markers and STL files were exported (n = 15). Superimposition was carried out by a software for determining the accuracy of both. (3) Results: Significant angular discrepancies (Delta A) and 3D deviations of scan bodies were found among the groups in trueness with lower deviations for the DPG (p value < 0.001). However, trueness within ISBs varied between angular and 3D deviations and outcomes were not specific to determine the effect of implant angulation. In precision, no significant differences were detected within ISBs and among both groups in terms of angular deviation. However, DPG had less deviations than DIOS group in terms of 3D deviations (p value < 0.001). (4) Conclusion: Digital photogrammetry technique conveyed the utmost accuracy in both trueness and precision for the intraoral scan bodies among both impression methods assessed. In addition, implant angulation did not influence the precision of the impression techniques but affected their trueness without explicit conclusions.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Mangano, Francesco Guido
    Admakin, Oleg
    Bonacina, Matteo
    Lerner, Henriette
    Rutkunas, Vygandas
    Mangano, Carlo
    [J]. BMC ORAL HEALTH, 2020, 20 (01)
  • [32] Impact of different scanning strategies on the accuracy of two current intraoral scanning systems in complete-arch impressions: an in vitro study
    Passos, Leandro
    Meiga, Sergio
    Brigagao, Vinicius
    Street, Alexandre
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2019, 22 (04) : 307 - 319
  • [33] Effect of novel prefabricated auxiliary devices attaching to scan bodies on the accuracy of intraoral scanning of complete-arch with multiple implants: An in-vitro study
    Wu, Hio Kuan
    Wang, Jing
    Chen, Guanhui
    Huang, Xiaoqiong
    Deng, Feilong
    Li, Yiming
    [J]. JOURNAL OF DENTISTRY, 2023, 138
  • [34] Learning curve of digital intraoral optical scanning for complete arch: an in vitro study
    Lio, F.
    Carosi, P.
    Mazzetti, V
    Arcuri, C.
    [J]. JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2022, 36 (02): : 19 - 27
  • [35] Accuracy of complete- and partial-arch impressions of actual intraoral scanning systems in vitro
    Ender, A.
    Zimmermann, M.
    Mehl, A.
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2019, 22 (01) : 11 - 19
  • [36] Accuracy of Digital Dental Implants Impression Taking with Intraoral Scanners Compared with Conventional Impression Techniques: A Systematic Review of In Vitro Studies
    Albanchez-Gonzalez, Maria Isabel
    Brinkmann, Jorge Cortes-Breton
    Pelaez-Rico, Jesus
    Lopez-Suarez, Carlos
    Rodriguez-Alonso, Veronica
    Suarez-Garcia, Maria Jesus
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (04)
  • [37] Influence of intraoral scanning coverage on the accuracy of digital implant impressions - An in vitro study
    Wang, Zhen-yu
    Gong, Yu
    Liu, Fei
    Chen, Du
    Shen, Jie-fei
    [J]. JOURNAL OF DENTISTRY, 2024, 143
  • [38] Influence of rescanning mesh holes and stitching procedures on the complete-arch scanning accuracy of an intraoral scanner: An in vitro study
    Gomez-Polo, Miguel
    Piedra-Cascon, Wenceslao
    Methani, Mohammed M.
    Quesada-Olmo, Nieves
    Farjas-Abadia, Mercedes
    Revilla-Leon, Marta
    [J]. JOURNAL OF DENTISTRY, 2021, 110
  • [39] Influence of Implant Scanbody Wear on the Accuracy of Digital Impression for Complete-Arch: A Randomized In Vitro Trial
    Arcuri, Lorenzo
    Lio, Fabrizio
    Campana, Veronica
    Mazzetti, Vincenzo
    Federici, Francesca Romana
    Nardi, Alessandra
    Galli, Massimo
    [J]. MATERIALS, 2022, 15 (03)
  • [40] Accuracy of complete-arch model using an intraoral video scanner: An in vitro study
    Jeong, Ii-Do
    Lee, Jae-Jun
    Jeon, Jin-Hun
    Kim, Ji-Hwan
    Kim, Hae-Young
    Kim, Woong-Chul
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (06): : 755 - 759