Physical characterization and comparison of two commercially available micro-MLCs

被引:6
|
作者
Podder, Tarun K. [1 ]
Bednarz, Greg [2 ]
Yu, Yan [1 ]
Galvin, James M. [1 ]
机构
[1] Thomas Jefferson Univ Hosp, Dept Radiat Oncol, Kimmel Canc Ctr NCI Designated, Jefferson Med Coll, Philadelphia, PA 19107 USA
[2] Univ Pittsburgh, Med Ctr, Dept Radiat Oncol, UPMC Canc Ctr, Pittsburgh, PA 15232 USA
关键词
Micromulti-leaf collimator; Penumbra; Interleaf leakage; Tongue-and-groove effect; Focal spot; IMRT; MULTILEAF COLLIMATOR SYSTEM;
D O I
10.1016/j.ejmp.2010.01.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study, the physical characteristics (penumbra width variation with the source size and shape, interleaf leakage, transmission through the leaves, and the tongue-and-groove effect) of two linear accelerators (BrainLAB's Novalis and Elekta's Synergy-S Beam Modulator) have been investigated. For similar square fields (about 4.5 cm x 4.5 cm) with source-to-surface/skin-distance (SSD) ranging from 90 cm to 115 cm and measurements taken at the depth of D(max) = 1.5 cm for 6 MV photon beam. The Novalis MLC has penumbra width of 2.4 +/- 0.11 mm-2.8 +/- 0.11 mm at the leaf-end and 2.2 +/- 0.1 mm-2.7 +/- 0.1 mm on the leaf-side; and those for the Synergy-S MLC are 4.4 +/- 0.17 mm-5.2 +/- 0.2 mm and 3.0 +/- 0.12 mm-3.5 +/- 0.12 mm. Upon rotating the Synergy-S collimator by 90 degrees (i.e., shifting the leaf movement to the gun target direction), significant reduction of the leaf-end penumbra width (17%) and increase of leaf-side penumbra width (28%) suggest an elliptical shape of the radiation source spot. Similar rotation of the collimator yielded reduction of the penumbras on both leaf-end (34%) and leaf-side (28%) for Novalis, indicating that the Novalis has a more symmetric source size. For all the field sizes and settings, BrainLAB's Novalis mu MLC produce a smaller penumbra for simple square fields compared to the Elekta's Synergy-S. However, this difference became less pronounced for leaf-side penumbra and also for circular fields. The tongue-and-groove effect of the Novalis (23 +/- 0.9%) is slightly smaller than that of the Synergy-S (25 +/- 1%); while the interleaf leakage and leakage directly through leaves for Synergy-S (1.6 +/- 0.07% a 0.9 +/- 0.04%) are lower than that of Novalis (2 +/- 0.08% & 1.3 +/- 0.05%). (C) 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:52 / 57
页数:6
相关论文
共 50 条
  • [1] Penumbra evaluation of the synergy-S and novalis Micro-MLCs
    Podder, T.
    Bednarz, G.
    Misic, V.
    Yu, Y.
    Galvin, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2480 - 2480
  • [2] Comparison of two commercially available cryoballoon ablation systems
    Diofano, F.
    Pflieger, C.
    Teumer, Y.
    Bothner, C.
    Rottbauer, W.
    Dahme, T.
    Weinmann, K.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [3] Comparison of two commercially available ELISAs for circulating sclerostin
    A. G. Costa
    S. Cremers
    E. Dworakowski
    M. Lazaretti-Castro
    J. P. Bilezikian
    Osteoporosis International, 2014, 25 : 1547 - 1554
  • [4] Comparison of two commercially available ELISAs for circulating sclerostin
    Costa, A. G.
    Cremers, S.
    Dworakowski, E.
    Lazaretti-Castro, M.
    Bilezikian, J. P.
    OSTEOPOROSIS INTERNATIONAL, 2014, 25 (05) : 1547 - 1554
  • [5] Characterization and comparison of commercially available mite extracts for in vivo diagnosis
    Brunetto, B.
    Tinghino, R.
    Braschi, M. C.
    Antonicelli, L.
    Pini, C.
    Iacovacci, P.
    ALLERGY, 2010, 65 (02) : 184 - 190
  • [6] Validation and comparison of two commercially available ELISAs for circulating sclerostin
    Costa, A. G.
    Cremers, S.
    Dworakowski, E.
    Nickolas, T. L.
    Rubin, M. R.
    Walker, M. D.
    Stein, E. M.
    Lazaretti-Castro, M.
    Silverberg, S. J.
    Bilezikian, J. P.
    BONE, 2012, 50 : S133 - S134
  • [7] Comparison Of Raw Acceleration From Two Commercially Available Accelerometers
    John, Dinesh
    Sasaki, Jeffer E.
    Staudenmayer, John
    Freedson, Patty S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 621 - 622
  • [8] Assessment of heparin anticoagulation: Comparison of two commercially available methods
    Flom-Halvorsen, HI
    Ovrum, E
    Abdelnoor, M
    Bjornsen, S
    Brosstad, F
    ANNALS OF THORACIC SURGERY, 1999, 67 (04): : 1012 - 1016
  • [9] Nephrotoxicity Comparison of Two Commercially Available Generic Vancomycin Products
    Sutton, Jesse D.
    Mynatt, Ryan P.
    Kaye, Keith S.
    Murray, Kyle P.
    Rybak, Michael J.
    Pogue, Jason M.
    ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2015, 59 (09) : 5470 - 5474
  • [10] Surface Characterization and Clinical Review of Two Commercially Available Implants
    Galli, Silvia
    Jimbo, Ryo
    Andersson, Martin
    Bryington, Matthew
    Albrektsson, Tomas
    IMPLANT DENTISTRY, 2013, 22 (05) : 507 - 518