Physical characterization and comparison of two commercially available micro-MLCs

被引:6
|
作者
Podder, Tarun K. [1 ]
Bednarz, Greg [2 ]
Yu, Yan [1 ]
Galvin, James M. [1 ]
机构
[1] Thomas Jefferson Univ Hosp, Dept Radiat Oncol, Kimmel Canc Ctr NCI Designated, Jefferson Med Coll, Philadelphia, PA 19107 USA
[2] Univ Pittsburgh, Med Ctr, Dept Radiat Oncol, UPMC Canc Ctr, Pittsburgh, PA 15232 USA
关键词
Micromulti-leaf collimator; Penumbra; Interleaf leakage; Tongue-and-groove effect; Focal spot; IMRT; MULTILEAF COLLIMATOR SYSTEM;
D O I
10.1016/j.ejmp.2010.01.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study, the physical characteristics (penumbra width variation with the source size and shape, interleaf leakage, transmission through the leaves, and the tongue-and-groove effect) of two linear accelerators (BrainLAB's Novalis and Elekta's Synergy-S Beam Modulator) have been investigated. For similar square fields (about 4.5 cm x 4.5 cm) with source-to-surface/skin-distance (SSD) ranging from 90 cm to 115 cm and measurements taken at the depth of D(max) = 1.5 cm for 6 MV photon beam. The Novalis MLC has penumbra width of 2.4 +/- 0.11 mm-2.8 +/- 0.11 mm at the leaf-end and 2.2 +/- 0.1 mm-2.7 +/- 0.1 mm on the leaf-side; and those for the Synergy-S MLC are 4.4 +/- 0.17 mm-5.2 +/- 0.2 mm and 3.0 +/- 0.12 mm-3.5 +/- 0.12 mm. Upon rotating the Synergy-S collimator by 90 degrees (i.e., shifting the leaf movement to the gun target direction), significant reduction of the leaf-end penumbra width (17%) and increase of leaf-side penumbra width (28%) suggest an elliptical shape of the radiation source spot. Similar rotation of the collimator yielded reduction of the penumbras on both leaf-end (34%) and leaf-side (28%) for Novalis, indicating that the Novalis has a more symmetric source size. For all the field sizes and settings, BrainLAB's Novalis mu MLC produce a smaller penumbra for simple square fields compared to the Elekta's Synergy-S. However, this difference became less pronounced for leaf-side penumbra and also for circular fields. The tongue-and-groove effect of the Novalis (23 +/- 0.9%) is slightly smaller than that of the Synergy-S (25 +/- 1%); while the interleaf leakage and leakage directly through leaves for Synergy-S (1.6 +/- 0.07% a 0.9 +/- 0.04%) are lower than that of Novalis (2 +/- 0.08% & 1.3 +/- 0.05%). (C) 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:52 / 57
页数:6
相关论文
共 50 条
  • [21] Clinical comparison of two commercially available lyme screening ELISA assays
    Dudley, T. A.
    Erwin, D.
    Ewell, A.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A141 - A141
  • [22] A Comparison and Evaluation of Two Commercially Available Metal Artifact Reduction Applications
    Osawa, Mitsuharu
    Fujita, Naotoshi
    Koyama, Shuji
    Kaneda, Naoki
    Miyachi, Shigeru
    JOURNAL OF NEUROENDOVASCULAR THERAPY, 2024, 18 (08) : 213 - 218
  • [23] Comparison of Two Commercially Available Software Platforms for Deformable Image Registration
    Tuohy, R.
    Stathakis, S.
    Mavroidis, P.
    Bosse, C.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2014, 41 (06) : 218 - 218
  • [24] Comparison of Aqueous Flow Rates With Two Commercially Available Vitrectomy Systems
    Chu, T. G.
    Buboltz, D. C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [25] Seed production in watermelon: A comparison between two commercially available pollinators
    Stanghellini, MS
    Ambrose, JT
    Schultheis, JR
    HORTSCIENCE, 1998, 33 (01) : 28 - 30
  • [26] COMPARISON OF THROMBOGENICITY OF COMMERCIALLY AVAILABLE CATHETERS
    DURST, S
    LESLIE, J
    MOORE, R
    AMPLATZ, K
    RADIOLOGY, 1974, 113 (03) : 599 - 600
  • [27] A data-driven comparison of commercially available testing methods for algae characterization
    Lane, Madeline
    Van Wychen, Stefanie
    Politis, Andy
    Laurens, Lieve M. L.
    ALGAL RESEARCH-BIOMASS BIOFUELS AND BIOPRODUCTS, 2021, 53
  • [28] Assessment of heparin anticoagulation: Comparison of two commercially available methods - Invited commentary
    Bidstrup, BP
    ANNALS OF THORACIC SURGERY, 1999, 67 (04): : 1016 - 1017
  • [29] Comparison of two commercially available systems proposed for oral administration of capsules in rats
    Chevalier, G.
    Papineau, D.
    Cirio, A.
    Lambert, Y.
    Reperant, G.
    Singh, P.
    TOXICOLOGY LETTERS, 2019, 314 : S259 - S259
  • [30] Comparison of two commercially available T cell receptor repertoire sequencing assays
    Mason, Jennifer
    Buchkovich, Martin
    Sims, Jennifer
    Hurban, Patrick
    CANCER RESEARCH, 2020, 80 (16)