Surface Characterization and Clinical Review of Two Commercially Available Implants

被引:3
|
作者
Galli, Silvia [1 ]
Jimbo, Ryo [1 ]
Andersson, Martin [2 ]
Bryington, Matthew [3 ]
Albrektsson, Tomas [1 ,4 ]
机构
[1] Malmo Univ, Fac Odontol, Dept Prosthodont, S-21421 Malmo, Sweden
[2] Chalmers Univ Technol, Dept Chem & Biol Engn, S-41296 Gothenburg, Sweden
[3] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH 43210 USA
[4] Gothenburg Univ, Dept Biomat, Gothenburg, Sweden
关键词
microtopography; nanofeatures; clinical review; survival rate; marginal bone loss; IMMEDIATELY LOADED IMPLANTS; PHOSPHATE-COATED IMPLANTS; NARROW DIAMETER IMPLANTS; CRESTAL BONE CHANGES; SCREW-TYPE IMPLANTS; 2-YEAR FOLLOW-UP; DENTAL IMPLANTS; MANDIBULAR OVERDENTURES; RADIOGRAPHIC EVALUATION; SUBCRESTAL POSITIONS;
D O I
10.1097/ID.0b013e318294308f
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose:To characterize topographically and chemically the surfaces of 2 commercially available implants. Furthermore, to gather an overview of the clinical results of these implant systems.Materials and Methods:Two commercially available oral implants were analyzed using optical interferometry, scanning electron microscopy, and energy dispersive spectroscopy. In addition, a literature search for all the clinical articles on the same implants was performed.Results:No significant differences of topographical parameters were found between the 2 implants, except for the hybrid parameter Sdr presenting significant higher values for the Ankylos implants. Both surfaces had a homogenous microporosity. At higher magnifications of scanning electron microscope images, evenly distributed nanostructures (approximately 10 nm) were visible. Chemically, mainly titanium, oxygen and carbon were detected. Fifty-six clinical articles were included for the review. The implant survival rates (minimum follow-up: 5 years) ranged between 87.7% and 100%.Conclusions:The examined commercially available implants showed a moderately rough surface, with a homogenous microporosity. Nanofeatures were detected on the surface of both implants. The clinical performances of these implants were comparable to that of other commercialized implant systems.
引用
收藏
页码:507 / 518
页数:12
相关论文
共 50 条
  • [1] Commercially Available Dental Implants: Review of Their Surface Characteristics
    Palmquist, Anders
    Engqvist, Hakan
    Lausmaa, Jukka
    Thomsen, Peter
    [J]. JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2012, 2 (02) : 112 - 124
  • [2] Comparison of Surface Modified Zirconia Implants With Commercially Available Zirconium and Titanium Implants: A Histological Study in Pigs
    Gredes, Tomasz
    Kubasiewicz-Ross, Pawel
    Gedrange, Tomasz
    Dominiak, Marzena
    Kunert-Keil, Christiane
    [J]. IMPLANT DENTISTRY, 2014, 23 (04) : 502 - 507
  • [3] Considerations during clinical operation of two commercially available cryomachines
    Rewcastle, JC
    Sandison, GA
    Saliken, JC
    Donnelly, BJ
    McKinnon, JG
    [J]. JOURNAL OF SURGICAL ONCOLOGY, 1999, 71 (02) : 106 - 111
  • [4] Evaluation of invitro degradation of commercially available breast implants
    Gindri, Izabelle de Mello
    de Azambuja, Lucas Kurth
    Barreto, Michele da Silva
    Salmoria, Gean Vitor
    de Mello Roesler, Carlos Rodrigo
    [J]. POLYMER TESTING, 2019, 79
  • [5] Physical characterization and comparison of two commercially available micro-MLCs
    Podder, Tarun K.
    Bednarz, Greg
    Yu, Yan
    Galvin, James M.
    [J]. PHYSICA MEDICA, 2011, 27 (01) : 52 - 57
  • [6] In vitro surface characteristics and impurity analysis of five different commercially available dental zirconia implants
    Beger, B.
    Goetz, H.
    Morlock, M.
    Schiegnitz, E.
    Al-Nawas, B.
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
  • [7] A review on synthesis and characterization of commercially available natural fibers: Part II
    Madhu, P.
    Sanjay, M. R.
    Senthamaraikannan, P.
    Pradeep, S.
    Saravanakumar, S. S.
    Yogesha, B.
    [J]. JOURNAL OF NATURAL FIBERS, 2019, 16 (01) : 25 - 36
  • [8] In vitro surface characteristics and impurity analysis of five different commercially available dental zirconia implants
    B. Beger
    H. Goetz
    M. Morlock
    E. Schiegnitz
    B. Al-Nawas
    [J]. International Journal of Implant Dentistry, 4
  • [9] Clinical comparison of two commercially available lyme screening ELISA assays
    Dudley, T. A.
    Erwin, D.
    Ewell, A.
    [J]. CLINICAL CHEMISTRY, 2007, 53 (06) : A141 - A141
  • [10] Comparison of Two Commercially Available Fentanyl Screening Immunoassays for Clinical Use
    Budelier, Melissa M.
    Franks, Caroline E.
    Logsdon, Nicole
    Jannetto, Paul J.
    Scott, Mitchell G.
    Roper, Stephen M.
    Farnsworth, Christopher W.
    [J]. JOURNAL OF APPLIED LABORATORY MEDICINE, 2020, 5 (06): : 1277 - 1286