Surface Characterization and Clinical Review of Two Commercially Available Implants

被引:3
|
作者
Galli, Silvia [1 ]
Jimbo, Ryo [1 ]
Andersson, Martin [2 ]
Bryington, Matthew [3 ]
Albrektsson, Tomas [1 ,4 ]
机构
[1] Malmo Univ, Fac Odontol, Dept Prosthodont, S-21421 Malmo, Sweden
[2] Chalmers Univ Technol, Dept Chem & Biol Engn, S-41296 Gothenburg, Sweden
[3] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH 43210 USA
[4] Gothenburg Univ, Dept Biomat, Gothenburg, Sweden
关键词
microtopography; nanofeatures; clinical review; survival rate; marginal bone loss; IMMEDIATELY LOADED IMPLANTS; PHOSPHATE-COATED IMPLANTS; NARROW DIAMETER IMPLANTS; CRESTAL BONE CHANGES; SCREW-TYPE IMPLANTS; 2-YEAR FOLLOW-UP; DENTAL IMPLANTS; MANDIBULAR OVERDENTURES; RADIOGRAPHIC EVALUATION; SUBCRESTAL POSITIONS;
D O I
10.1097/ID.0b013e318294308f
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose:To characterize topographically and chemically the surfaces of 2 commercially available implants. Furthermore, to gather an overview of the clinical results of these implant systems.Materials and Methods:Two commercially available oral implants were analyzed using optical interferometry, scanning electron microscopy, and energy dispersive spectroscopy. In addition, a literature search for all the clinical articles on the same implants was performed.Results:No significant differences of topographical parameters were found between the 2 implants, except for the hybrid parameter Sdr presenting significant higher values for the Ankylos implants. Both surfaces had a homogenous microporosity. At higher magnifications of scanning electron microscope images, evenly distributed nanostructures (approximately 10 nm) were visible. Chemically, mainly titanium, oxygen and carbon were detected. Fifty-six clinical articles were included for the review. The implant survival rates (minimum follow-up: 5 years) ranged between 87.7% and 100%.Conclusions:The examined commercially available implants showed a moderately rough surface, with a homogenous microporosity. Nanofeatures were detected on the surface of both implants. The clinical performances of these implants were comparable to that of other commercialized implant systems.
引用
收藏
页码:507 / 518
页数:12
相关论文
共 50 条
  • [41] CHARACTERIZATION OF FIVE COMMERCIALLY AVAILABLE SAMPLES OF ACRIDINE YELLOW
    HOUBAHERIN, N
    DEGRAEVE, J
    CALBERGBACQ, CM
    VANDEVORST, A
    [J]. STAIN TECHNOLOGY, 1983, 58 (03): : 161 - 170
  • [42] The Evaluation of Two Commercially Available, Portable Raman Systems
    Mosier-Boss, Pamela A.
    Putnam, Michael D.
    [J]. ANALYTICAL CHEMISTRY INSIGHTS, 2013, 8 : 83 - 97
  • [43] CHARACTERIZATION OF COMMERCIALLY AVAILABLE ENAMELS FOR USE ON CAST TITANIUM
    MENIS, DL
    MOSER, JB
    MARSHALL, SJ
    [J]. JOURNAL OF DENTAL RESEARCH, 1987, 66 : 294 - 294
  • [44] Characterization of commercially available and synthesized polyethylenimines for gene delivery
    von Harpe, A
    Petersen, H
    Li, YX
    Kissel, T
    [J]. JOURNAL OF CONTROLLED RELEASE, 2000, 69 (02) : 309 - 322
  • [45] Radiological characterization of commercially available “radon spa sources”
    T. Ishikawa
    M. Hosoda
    A. Sorimachi
    S. Tokonami
    S. Katoh
    S. Ogashiwa
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2011, 287 : 709 - 713
  • [46] Characterization of an assortment of commercially available multiwalled carbon nanotubes
    Keith E. Levine
    Li Han
    Andrea C. McWilliams
    Amal S. Essader
    Kelly E. Amato
    Reshan A. Fernando
    Donna B. Browning
    Lisa C. Greene
    David S. Ensor
    Nigel J. Walker
    Veronica G. Robinson
    Bradley J. Collins
    [J]. Microchimica Acta, 2014, 181 : 171 - 179
  • [47] A Review of Commercially Available 3D Surface Imaging Systems for Body Composition Estimation
    Bullas, Alice May
    Greenwood, Rebecca
    Thelwell, Michael
    Choppin, Simon
    [J]. APPLIED SCIENCES-BASEL, 2022, 12 (17):
  • [48] EFFECTS OF TWO PACING CONTINGENCIES IN COMMERCIALLY AVAILABLE MATERIALS
    MCLAUGHLIN, TF
    MALABY, JE
    [J]. IMPROVING HUMAN PERFORMANCE QUARTERLY, 1974, 3 (04): : 187 - 198
  • [49] Comparison of two commercially available cryoballoon ablation systems
    Diofano, F.
    Pflieger, C.
    Teumer, Y.
    Bothner, C.
    Rottbauer, W.
    Dahme, T.
    Weinmann, K.
    [J]. EUROPEAN HEART JOURNAL, 2023, 44
  • [50] Comparison of two commercially available ELISAs for circulating sclerostin
    A. G. Costa
    S. Cremers
    E. Dworakowski
    M. Lazaretti-Castro
    J. P. Bilezikian
    [J]. Osteoporosis International, 2014, 25 : 1547 - 1554