Comparison of HASTE with multiple signal averaging versus conventional turbo spin echo sequence: a new option for T2-weighted MRI of the female pelvis

被引:12
|
作者
Tsuboyama, Takahiro [1 ]
Takei, Oki [1 ]
Okada, Atsuhiko [1 ]
Honda, Toru [1 ]
Kuriyama, Keiko [1 ]
机构
[1] Natl Hosp Org Osaka Natl Hosp, Dept Radiol, Chuo Ku, 2-1-14 Hoenzaka, Osaka 5400006, Japan
关键词
Magnetic resonance imaging; Spin echo imaging; Pelvis; Female; IMAGE QUALITY; INCREASED SPEED; ACQUISITION; BLADE; 3D;
D O I
10.1007/s00330-020-06686-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives This study was conducted in order to evaluate the feasibility of a newly developed half-Fourier acquisition single-shot turbo spin echo (HASTE) sequence for T2-weighted MRI of the female pelvis, in which scanning and post-processing filtering techniques were optimized to minimize blurring and the resultant reduction in signal-to-noise ratio (SNR) was compensated by signal averaging of multiple excitations (multi-NEX), and to compare its image quality with that of a conventional turbo spin echo (TSE) sequence. Methods Fifty females with gynecological disease were prospectively enrolled. They underwent pelvic MRI including sagittal T2-weighted imaging obtained with multi-NEX HASTE (mHASTE) and TSE with acquisition times of 1 m 9 s and 3 m 26 s, respectively. At the prospective reading, mHASTE was reviewed first, and any changes in the image interpretation detected during the subsequent TSE reading were recorded. The SNR and tissue contrast were quantitatively measured. Two radiologists independently assessed tissue conspicuity and overall image quality considering noise, artifacts, and blurring, and visual grading characteristics (VGC) analysis was performed to compare the two sequences. Results Adding TSE to mHASTE did not change image interpretations in any case. mHASTE produced an equivalent SNR and significantly higher contrast between the myometrium and junctional zone (p < 0.05) compared with TSE. The area under the VGC curve (AUC(VGC)) showed that the conspicuity of the uterus, ovaries, and lesions and the overall image quality were significantly higher on mHASTE than on TSE for both readers (AUC(VGC), 0.740-0.880; p < 0.01). Conclusion mHASTE is a feasible option for T2-weighted MRI of the female pelvis, as it allows faster and higher-quality image acquisition than conventional TSE.
引用
收藏
页码:3245 / 3253
页数:9
相关论文
共 50 条
  • [21] Fast breath-hold T2-weighted MRI of the kidney by means of half-Fourier single-shot turbo spin echo: Comparison with high resolution turbo spin echo sequence
    Nakayama, Y
    Yamashita, Y
    Matsuno, Y
    Tang, Y
    Namimoto, T
    Kadota, M
    Mitsuzaki, K
    Abe, Y
    Katahira, K
    Arakawa, A
    Takahashi, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (01) : 55 - 60
  • [22] A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque
    Peng Lv
    Yuanyuan Dai
    Jiang Lin
    Weisheng Zhang
    Hao Liu
    Hui Liu
    Xiao Tang
    The International Journal of Cardiovascular Imaging, 2017, 33 : 395 - 400
  • [23] MRT versus CT in the diagnosis of pneumonia:: evaluation of a T2-weighted ultrafast turbo-spin-echo sequence (UTSE).
    Leutner, C
    Gieseke, J
    Lutterbey, G
    Kuhl, CK
    Flacke, S
    Glasmacher, A
    Theisen, A
    Wardelmann, E
    Grohe, C
    Schild, HH
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (05): : 449 - 456
  • [24] Fast T2-weighted liver MR imaging: comparison among breath-hold turbo-spin-echo, HASTE, and inversion recovery (IR) HASTE sequences
    Lee, MG
    Jeong, YK
    Kim, JC
    Kang, EM
    Kim, PN
    Auh, YH
    Chien, D
    Laub, G
    ABDOMINAL IMAGING, 2000, 25 (01): : 93 - 99
  • [25] Fast T2-weighted liver MR imaging: comparison among breath-hold turbo-spin-echo, HASTE, and inversion recovery (IR) HASTE sequences
    M.-G. Lee
    Y. K. Jeong
    J. C. Kim
    E. M. Kang
    P. N. Kim
    Y. H. Auh
    D. Chien
    G. Laub
    Abdominal Imaging, 2000, 25 : 93 - 99
  • [26] Detection and characterization of focal hepatic lesions by T2-weighted imaging: comparison of navigator-triggered turbo spin-echo, breath-hold turbo spin-echo, and HASTE sequences
    Lee, Ho Yun
    Lee, Jeong Min
    Kim, Se Hyung
    Shin, Kyung Sook
    Lee, Jae Young
    Han, Joon Koo
    Choi, Byung Ihn
    CLINICAL IMAGING, 2009, 33 (04) : 281 - 288
  • [27] TURBO GRADIENT-SPIN-ECHO (GRASE) - FIRST CLINICAL-EXPERIENCES WITH A FAST T2-WEIGHTED SEQUENCE IN MRI OF THE BRAIN
    FELLNER, F
    SCHMITT, R
    TRENKLER, J
    FELLNER, C
    BOHMJURKOVIC, H
    EUROPEAN JOURNAL OF RADIOLOGY, 1995, 19 (03) : 171 - 176
  • [28] Synthetic T2-weighted images of the lumbar spine derived from an accelerated T2 mapping sequence: Comparison to conventional T2w turbo spin echo
    Raudner, Marcus
    Toth, Daniel F.
    Schreiner, Markus M.
    Hilbert, Tom
    Kober, Tobias
    Juras, Vladimir
    Windhager, Reinhard
    Trattnig, Siegfried
    MAGNETIC RESONANCE IMAGING, 2021, 84 : 92 - 100
  • [29] Comparison of oblique coronal images in knee of three-dimensional isotropic T2-weighted turbo spin echo MRI versus two-dimensional fast spin echo T2-weighted sequences for evaluation of posterior cruciate ligament injury
    Park, Hee J.
    Lee, So Y.
    Choi, Seon H.
    Ahn, Jin H.
    Park, Se J.
    Park, Jai H.
    Kim, Eugene
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1067):
  • [30] Signal characteristics of focal liver lesions on double echo T2-weighted conventional spin echo MRI: Observer performance versus quantitative measurements of T2 relaxation times
    Fenlon, HM
    Tello, R
    deCarvalho, VLS
    Yucel, EK
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (02) : 204 - 211