Comparison of HASTE with multiple signal averaging versus conventional turbo spin echo sequence: a new option for T2-weighted MRI of the female pelvis

被引:12
|
作者
Tsuboyama, Takahiro [1 ]
Takei, Oki [1 ]
Okada, Atsuhiko [1 ]
Honda, Toru [1 ]
Kuriyama, Keiko [1 ]
机构
[1] Natl Hosp Org Osaka Natl Hosp, Dept Radiol, Chuo Ku, 2-1-14 Hoenzaka, Osaka 5400006, Japan
关键词
Magnetic resonance imaging; Spin echo imaging; Pelvis; Female; IMAGE QUALITY; INCREASED SPEED; ACQUISITION; BLADE; 3D;
D O I
10.1007/s00330-020-06686-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives This study was conducted in order to evaluate the feasibility of a newly developed half-Fourier acquisition single-shot turbo spin echo (HASTE) sequence for T2-weighted MRI of the female pelvis, in which scanning and post-processing filtering techniques were optimized to minimize blurring and the resultant reduction in signal-to-noise ratio (SNR) was compensated by signal averaging of multiple excitations (multi-NEX), and to compare its image quality with that of a conventional turbo spin echo (TSE) sequence. Methods Fifty females with gynecological disease were prospectively enrolled. They underwent pelvic MRI including sagittal T2-weighted imaging obtained with multi-NEX HASTE (mHASTE) and TSE with acquisition times of 1 m 9 s and 3 m 26 s, respectively. At the prospective reading, mHASTE was reviewed first, and any changes in the image interpretation detected during the subsequent TSE reading were recorded. The SNR and tissue contrast were quantitatively measured. Two radiologists independently assessed tissue conspicuity and overall image quality considering noise, artifacts, and blurring, and visual grading characteristics (VGC) analysis was performed to compare the two sequences. Results Adding TSE to mHASTE did not change image interpretations in any case. mHASTE produced an equivalent SNR and significantly higher contrast between the myometrium and junctional zone (p < 0.05) compared with TSE. The area under the VGC curve (AUC(VGC)) showed that the conspicuity of the uterus, ovaries, and lesions and the overall image quality were significantly higher on mHASTE than on TSE for both readers (AUC(VGC), 0.740-0.880; p < 0.01). Conclusion mHASTE is a feasible option for T2-weighted MRI of the female pelvis, as it allows faster and higher-quality image acquisition than conventional TSE.
引用
收藏
页码:3245 / 3253
页数:9
相关论文
共 50 条
  • [31] Assessment of coronary artery bypass graft patency with a 2D T2-weighted breath-hold Turbo-Spin-Echo sequence (HASTE)
    Kalden, P
    Kreitner, KF
    Wittlinger, T
    Voigtländer, T
    Krummenauer, F
    Schreiber, W
    Thelen, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (05): : 442 - 448
  • [32] TRUE PROTON DENSITY AND T2-WEIGHTED TURBO SPIN-ECHO SEQUENCES FOR ROUTINE MRI OF THE BRAIN
    FELLNER, F
    SCHMITT, R
    TRENKLER, J
    FELLNER, C
    HELMBERGER, T
    OBLETTER, N
    BOHMJURKOVIC, H
    NEURORADIOLOGY, 1994, 36 (08) : 591 - 597
  • [33] Imaging of the degenerative spine using a sagittal T2-weighted DIXON turbo spin-echo sequence
    Sollmann, Nico
    Moench, Sebastian
    Riederer, Isabelle
    Zimmer, Claus
    Baum, Thomas
    Kirschke, Jan S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 131
  • [34] Multiple Sclerosis: Comparison of the Conventional Spin-Echo T2-Weighted and Flair Techniques Through Image Processing
    Simao, Ricardo Silva
    de Azevedo Alves, Rafaela Ferreira
    Matos da Silva Boschi, Silvia Regina
    Scardovelli, Terigi Augusto
    Martini Rodrigues, Silvia Cristina
    Bianchi, Cesario
    da Silva, Alessandro Pereira
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (03) : 425 - 430
  • [35] Comparison of Sagittal T2-Weighted BLADE and Fast Spin Echo MR Imaging of the Female Pelvis for Motion Artifact and Lesion Detection
    Lane, B.
    Qureshi, F.
    Oz, R.
    Irwin, E.
    McMillan, A.
    Wong-You-Cheong, J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [36] T2-weighted MRI of the female pelvis: Comparison of breath-hold fast-recovery fast spin-echo and nonbreath-hold fast spin-echo sequences
    Masui, T
    Katayama, M
    Kobayashi, S
    Sakahara, H
    Ito, T
    Nozaki, A
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (06) : 930 - 937
  • [37] BLADE acquisition method improves T2-weighted MR images of the female pelvis compared with a standard fast spin-echo sequence
    Fujimoto, Koji
    Koyama, Takashi
    Tamai, Ken
    Morisawa, Nobuko
    Okada, Tomohisa
    Togashi, Kaori
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) : 796 - 801
  • [38] T2-weighted magnetic resonance imaging of the liver: comparison of fat-suppressed GRASE with conventional spin echo, fat-suppressed turbo spin echo, and gradient echo at 1.0 T
    A. H. Karantanas
    N. Papanikolaou
    Abdominal Imaging, 2001, 26 : 139 - 145
  • [39] T2-weighted magnetic resonance imaging of the liver: comparison of fat-suppressed GRASE with conventional spin echo, fat-suppressed turbo spin echo, and gradient echo at 1.0 T
    Karantanas, AH
    Papanikolaou, N
    ABDOMINAL IMAGING, 2001, 26 (02): : 139 - 145
  • [40] REDUCTION OF MRT TIMING FOR EXAMINATION OF THE FEMALE PELVIS USING T2-WEIGHTED FAST SPIN-ECHO (FSE) TECHNIQUES - QUANTITATIVE AND QUALITATIVE COMPARISON OF CONVENTIONAL SPIN-ECHO (SE) AND FAST SPIN-ECHO (FSE)
    HALDEMANN, RC
    KRESTIN, GP
    DUEWELL, S
    MARINCEK, B
    VONSCHULTHESS, GK
    SAADIELMANDJRA, M
    FUCHS, WA
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 158 (02): : 127 - 132