Comparison of HASTE with multiple signal averaging versus conventional turbo spin echo sequence: a new option for T2-weighted MRI of the female pelvis

被引:12
|
作者
Tsuboyama, Takahiro [1 ]
Takei, Oki [1 ]
Okada, Atsuhiko [1 ]
Honda, Toru [1 ]
Kuriyama, Keiko [1 ]
机构
[1] Natl Hosp Org Osaka Natl Hosp, Dept Radiol, Chuo Ku, 2-1-14 Hoenzaka, Osaka 5400006, Japan
关键词
Magnetic resonance imaging; Spin echo imaging; Pelvis; Female; IMAGE QUALITY; INCREASED SPEED; ACQUISITION; BLADE; 3D;
D O I
10.1007/s00330-020-06686-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives This study was conducted in order to evaluate the feasibility of a newly developed half-Fourier acquisition single-shot turbo spin echo (HASTE) sequence for T2-weighted MRI of the female pelvis, in which scanning and post-processing filtering techniques were optimized to minimize blurring and the resultant reduction in signal-to-noise ratio (SNR) was compensated by signal averaging of multiple excitations (multi-NEX), and to compare its image quality with that of a conventional turbo spin echo (TSE) sequence. Methods Fifty females with gynecological disease were prospectively enrolled. They underwent pelvic MRI including sagittal T2-weighted imaging obtained with multi-NEX HASTE (mHASTE) and TSE with acquisition times of 1 m 9 s and 3 m 26 s, respectively. At the prospective reading, mHASTE was reviewed first, and any changes in the image interpretation detected during the subsequent TSE reading were recorded. The SNR and tissue contrast were quantitatively measured. Two radiologists independently assessed tissue conspicuity and overall image quality considering noise, artifacts, and blurring, and visual grading characteristics (VGC) analysis was performed to compare the two sequences. Results Adding TSE to mHASTE did not change image interpretations in any case. mHASTE produced an equivalent SNR and significantly higher contrast between the myometrium and junctional zone (p < 0.05) compared with TSE. The area under the VGC curve (AUC(VGC)) showed that the conspicuity of the uterus, ovaries, and lesions and the overall image quality were significantly higher on mHASTE than on TSE for both readers (AUC(VGC), 0.740-0.880; p < 0.01). Conclusion mHASTE is a feasible option for T2-weighted MRI of the female pelvis, as it allows faster and higher-quality image acquisition than conventional TSE.
引用
收藏
页码:3245 / 3253
页数:9
相关论文
共 50 条
  • [41] MRI of the female pelvis at 3T compared to 1.5T: Evaluation on high-resolution T2-weighted and HASTE images
    Kataoka, Masako
    Kido, Aki
    Koyama, Takashi
    Isoda, Hiroyoshi
    Umeoka, Shigeaki
    Tamai, Ken
    Nakamoto, Yuji
    Maetani, Yoji
    Morisawa, Nobuko
    Saga, Tsuneo
    Togashi, Kaori
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (03) : 527 - 534
  • [42] MRI of the regions of inner ear and cerebellopontine angle using a 3D T-2-weighted turbo spin-echo sequence: Comparison with conventional 2D T-2-weighted turbo spin-echo sequences and T-1-weighted spin-echo sequences.
    Czerny, C
    Trattnig, S
    Baumgartner, WD
    Gstottner, W
    Imhof, H
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (04): : 377 - 383
  • [43] COMPARISON OF RESPIRATORY-TRIGGERED T2-WEIGHTED TURBO SPIN-ECHO IMAGING VERSUS BREATH-HOLD T2-WEIGHTED TURBO SPIN-ECHO IMAGING: DISTINGUISHING BENIGN FROM MALIGNANT LIVER LESIONS IN PATIENTS WITH COLORECTAL CANCER
    Coenegrachts, K.
    ter Beek, L.
    Haspeslagh, M.
    Bipat, S.
    Stoker, J.
    Rigauts, H.
    JBR-BTR, 2009, 92 (04): : 195 - 201
  • [44] Editorial for "Comparison of a Deep Learning-Accelerated Versus Conventional T2-Weighted Sequence in Biparametric MRI of the Prostate"
    Wu, Zhe
    Bhayana, Rajesh
    Uludag, Kamil
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 58 (04) : 1065 - 1066
  • [45] Rapid T2-weighted turbo spin echo MultiVane brain MRI using compressed SENSE: a qualitative analysis
    Sartoretti, E.
    Wyss, M.
    Eichenberger, B.
    van Smoorenburg, L.
    Binkert, C. A.
    Sartoretti-Schefer, S.
    Sartoretti, T.
    CLINICAL RADIOLOGY, 2021, 76 (10) : 786.e15 - 786.e22
  • [46] APPLICATION OF FAST SPIN-ECHO T(2)-WEIGHTED IMAGING FOR EXAMINATION OF THE NEUROCRANIUM - COMPARISON WITH THE CONVENTIONAL T(2)-WEIGHTED SPIN-ECHO SEQUENCE
    SIEWERT, C
    HOSTEN, N
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (01): : 44 - 50
  • [47] Comparison of single-echo T2-weighted fast spin-echo and conventional spin-echo MR sequences - In the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Banco, A
    Miraglia, R
    Nicastro, T
    Lagalla, R
    RIVISTA DI NEURORADIOLOGIA, 1998, 11 (04): : 471 - 476
  • [48] T2-weighted MRI for the assessment of joint effusion: Comparative study of conventional spin-echo and fast spin-echo sequences
    Mori, S
    Kaneda, T
    Lee, K
    Kato, M
    Motohashi, J
    Ogura, I
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2004, 97 (06): : 768 - 774
  • [49] Fast MR imaging of focal hepatic lesions: Comparison of breath-hold turbo SE, breath-hold HASTE, and breath-hold HASTE STIR versus conventional T2-weighted SE sequence
    Lee, M
    Jeong, YK
    Han, D
    Seo, DJ
    Auh, YH
    Chien, D
    RADIOLOGY, 1996, 201 : 435 - 435
  • [50] Diagnosis of Hepatic Metastasis: Comparison of Respiration-Triggered Diffusion-Weighted Echo-Planar MRI and Five T2-Weighted Turbo Spin-Echo Sequences
    Bruegel, Melanie
    Gaa, Jochen
    Waldt, Simone
    Woertler, Klaus
    Holzapfel, Konstantin
    Kiefer, Berthold
    Rummeny, Ernst J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (05) : 1421 - 1429