Comparison of oblique coronal images in knee of three-dimensional isotropic T2-weighted turbo spin echo MRI versus two-dimensional fast spin echo T2-weighted sequences for evaluation of posterior cruciate ligament injury

被引:7
|
作者
Park, Hee J. [1 ]
Lee, So Y. [1 ]
Choi, Seon H. [1 ]
Ahn, Jin H. [2 ]
Park, Se J. [2 ]
Park, Jai H. [2 ]
Kim, Eugene [2 ]
机构
[1] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Dept Radiol, Sch Med, Seoul, South Korea
[2] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Dept Orthopaed Surg, Sch Med, Seoul, South Korea
来源
BRITISH JOURNAL OF RADIOLOGY | 2016年 / 89卷 / 1067期
关键词
3.0; T; DIAGNOSTIC PERFORMANCE; T2-WEIGHTED SEQUENCES; INITIAL-EXPERIENCE; ANKLE MRI; 3D; TEARS; PLANE;
D O I
10.1259/bjr.20160554
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare image quality between three-dimensional volume isotropic turbo spin echo acquisition (3D VISTA) with the posterior cruciate ligament (PCL) view and two-dimensional (2D) fast spin echo (FSE) for evaluation of PCL injury. Methods: This retrospective study included 60 patients with clinical suspicion of PCL injury who underwent both 2D FSE and 3D VISTA of the knee between January 2015 and December 2015, The diagnostic performance of each oblique corona! view and the combined images was evaluated for sensitivity, specificity and accuracy for diagnosing a PCL tear. The arthroscopically confirmed diagnoses were used as the reference standard. Data were analyzed using the McNemar test. Results: The mean contrast-to-noise ratio was significantly higher for 3D VISTA than for 2D FSE. The two imaging modalities did not differ significantly in anatomical identification ability, with the exception of margin sharpness, which was inferior for 3D VISTA with Reader 2 (p = 0.038). When we classified the diagnoses of PCL injury as normal or abnormal, there were no significant differences in sensitivity, specificity or accuracy between the PCL view of 3D VISTA and 2D FSE images (p > 0,05), Conclusion: 3D VISTA had a superior contrast-to-noise ratio than 2D FSE and similar image quality in the evaluation of the PCL. The PCL view of 3D VISTA has the same diagnostic ability as 2D FSE in the diagnosis of PCL injury and can thus replace 2D FSE. Advances in knowledge: The oblique coronal view 3D VISTA MRI has similar diagnostic ability to 2D FSE in the diagnosis of PCL injury, and therefore 3D VISTA image can replace 2D FSE.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] The usefulness of the oblique coronal plane of three-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI in the evaluation of posterior cruciate ligament reconstruction with allograft: Comparison with the oblique coronal plane of two-dimensional fast spin-echo T2-weighted sequences
    Park, Hee Jin
    Lee, So Yeon
    Choi, Yoon Jung
    Choi, Seon Hyeong
    Kim, Mi Sung
    Ahn, Jin Hwan
    Park, Ji Yeon
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2019, 114 : 105 - 110
  • [2] Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) ankle MRI versus two-dimensional fast spin-echo T2-weighted sequences for the evaluation of anterior talofibular ligament injury
    Park, H. J.
    Lee, S. Y.
    Park, N. H.
    Rho, M. H.
    Chung, E. C.
    Park, J. H.
    Park, S. J.
    [J]. CLINICAL RADIOLOGY, 2016, 71 (04) : 349 - 355
  • [3] Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI at 3.0T in the evaluation of the anterior cruciate ligament injury with additional views: comparison with two-dimensional fast spin-echo T2-weighted sequences
    Park, Hee Jin
    Lee, So Yeon
    Park, Noh Hyuck
    Ahn, Jin Hwan
    Chung, Eun Chul
    Kim, Sung Jun
    Cha, Jang Gyu
    [J]. ACTA RADIOLOGICA, 2016, 57 (11) : 1372 - 1379
  • [4] 3D isotropic T2-weighted fast spin echo (VISTA) versus 2D T2-weighted fast spin echo in evaluation of the calcaneofibular ligament in the oblique coronal plane
    Park, H. J.
    Lee, S. Y.
    Choi, Y. J.
    Hong, H. P.
    Park, S. J.
    Park, J. H.
    Kim, E.
    [J]. CLINICAL RADIOLOGY, 2017, 72 (02) : 176.e1 - 176.e7
  • [5] Three-dimensional isotropic T2-weighted cervical MRI at 3 T: Comparison with two-dimensional T2-weighted sequences
    Kwon, J. W.
    Yoon, Y. C.
    Choi, S. -H.
    [J]. CLINICAL RADIOLOGY, 2012, 67 (02) : 106 - 113
  • [6] Usefulness of the oblique view of three-dimensional isotropic T2-weighted fast spin-echo (VISTA) in the evaluation of anterior cruciate ligament reconstruction
    Yi, Jung Woo
    Park, Hee Jin
    Lee, So Yeon
    Rho, Myung Ho
    Chung, Eun Chul
    Kim, Mi Sung
    Park, Jai Hyung
    Park, Se Jin
    [J]. CLINICAL IMAGING, 2016, 40 (04) : 610 - 616
  • [7] Quality comparison between three-dimensional T2-weighted SPACE and two-dimensional T2-weighted turbo spin echo magnetic resonance images for the brachytherapy planning evaluation of prostate and periprostatic anatomy
    Bathala, Tharakeswara K.
    Venkatesan, Aradhana M.
    Ma, Jingfei
    Bhosale, Priyadarshini
    Wei, Wei
    Kudchadker, Rajat J.
    Wang, Jihong
    Anscher, Mitchell S.
    Tang, Chad
    Bruno, Teresa L.
    Frank, Steven J.
    Szklaruk, Janio
    [J]. BRACHYTHERAPY, 2020, 19 (04) : 484 - 490
  • [8] Comparison of two-dimensional fast spin echo T2 weighted sequences and three-dimensional volume isotropic T2 weighted fast spin echo (VISTA) MRI in the evaluation of triangular fibrocartilage of the wrist
    Park, Hee Jin
    Lee, So Yeon
    Kang, Kyung A.
    Kim, Eun Young
    Shin, Hun Kyu
    Park, Se Jin
    Park, Jai Hyung
    Kim, Eugene
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1084):
  • [9] T2-weighted three-dimensional turbo spin-echo MR of intracranial aneurysms
    Rubinstein, D
    Sandberg, EJ
    Breeze, RE
    Sheppard, SK
    Perkins, TG
    CajadeLaw, AG
    Simon, JH
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (10) : 1939 - 1943
  • [10] Evaluation of diagnostic value and T2-weighted three-dimensional isotropic turbo spin-echo (3D-SPACE) image quality in comparison with T2-weighted two-dimensional turbo spin-echo (2D-TSE) sequences in lumbar spine MR imaging
    Hossein, Jomleh
    Fariborz, Faeghi
    Mehrnaz, Rasteh
    Babak, Rafiei
    [J]. EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2019, 6 : 36 - 41