Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) ankle MRI versus two-dimensional fast spin-echo T2-weighted sequences for the evaluation of anterior talofibular ligament injury

被引:33
|
作者
Park, H. J. [1 ]
Lee, S. Y. [1 ]
Park, N. H. [2 ]
Rho, M. H. [1 ]
Chung, E. C. [1 ]
Park, J. H. [3 ]
Park, S. J. [3 ]
机构
[1] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Sch Med, Dept Radiol, Seoul, South Korea
[2] Seonam Univ, Myongji Hosp, Coll Med, Dept Radiol, Hwajong Dong 697-24, Koyang 412270, Kyunggido, South Korea
[3] Sungkyunkwan Univ, Sch Med, Kangbuk Samsung Hosp, Dept Orthopaed Surg, Seoul, South Korea
关键词
3.0; T; DIAGNOSTIC PERFORMANCE; 3D; KNEE; JOINT;
D O I
10.1016/j.crad.2015.12.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To compare the performance of axial images of the ankle joint on three-dimensional (3D) volume isotropic turbo spin echo acquisition (VISTA) with that of two-dimensional (2D) fast spin echo (FSE) T2-weighted images for the diagnosis of anterior talofibular ligament (ATFL) injury. MATERIALS AND METHODS: This retrospective study included 101 patients who underwent both 2D FSE T2-weighted and 3D VISTA magnetic resonance imaging (MRI) of the ankle. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of both sequences were measured. The anatomical identification score and diagnostic performances of both sequences were evaluated by two radiologists. The diagnostic performances of 3D VISTA and 2D FSE images were analysed in terms of sensitivity, specificity, and accuracy for diagnosing ATFL injury. Surgically or clinically confirmed diagnoses were used as reference standards. RESULTS: The margin sharpness scores on 3D VISTA were significantly inferior to those of 2D FSE (p<0.001). Other scores (entire length, entire width) were not significantly different between the two imaging methods. The SNRs and CNRs of 3D VISTA were significantly higher than those of 2D FSE (p<0.001). When diagnoses were classified as normal and abnormal, the specificity of the 3D VISTA images for the diagnosis of ATFL injury was 95.7%, significantly superior to 2D FSE (84.3-85.7%). There were no significant differences between 3D VISTA and 2D FSE images in sensitivity or accuracy for diagnosis (p = 0.227-1.000), with the exception of accuracy by reader 1 (p = 0.039). CONCLUSION: 3D VISTA imaging has a diagnostic performance comparable to that of 2D FSE for the diagnosis of ATFL injury, although 3D VISTA is inferior to 2D FSE for the evaluation of margin sharpness. Replacing axial and coronal images with 3D VISTA can save imaging time without negatively impacting the diagnostic ability for ATFL injury. (C) 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:349 / 355
页数:7
相关论文
共 50 条
  • [1] Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI at 3.0T in the evaluation of the anterior cruciate ligament injury with additional views: comparison with two-dimensional fast spin-echo T2-weighted sequences
    Park, Hee Jin
    Lee, So Yeon
    Park, Noh Hyuck
    Ahn, Jin Hwan
    Chung, Eun Chul
    Kim, Sung Jun
    Cha, Jang Gyu
    [J]. ACTA RADIOLOGICA, 2016, 57 (11) : 1372 - 1379
  • [2] The usefulness of the oblique coronal plane of three-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI in the evaluation of posterior cruciate ligament reconstruction with allograft: Comparison with the oblique coronal plane of two-dimensional fast spin-echo T2-weighted sequences
    Park, Hee Jin
    Lee, So Yeon
    Choi, Yoon Jung
    Choi, Seon Hyeong
    Kim, Mi Sung
    Ahn, Jin Hwan
    Park, Ji Yeon
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2019, 114 : 105 - 110
  • [3] Usefulness of the oblique view of three-dimensional isotropic T2-weighted fast spin-echo (VISTA) in the evaluation of anterior cruciate ligament reconstruction
    Yi, Jung Woo
    Park, Hee Jin
    Lee, So Yeon
    Rho, Myung Ho
    Chung, Eun Chul
    Kim, Mi Sung
    Park, Jai Hyung
    Park, Se Jin
    [J]. CLINICAL IMAGING, 2016, 40 (04) : 610 - 616
  • [4] Comparison of oblique coronal images in knee of three-dimensional isotropic T2-weighted turbo spin echo MRI versus two-dimensional fast spin echo T2-weighted sequences for evaluation of posterior cruciate ligament injury
    Park, Hee J.
    Lee, So Y.
    Choi, Seon H.
    Ahn, Jin H.
    Park, Se J.
    Park, Jai H.
    Kim, Eugene
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1067):
  • [5] COMPARISON OF T2-WEIGHTED SPIN-ECHO AND FAST SPIN-ECHO TECHNIQUES IN THE EVALUATION OF MYELINATION
    PRENGER, EC
    BECKETT, WW
    KOLLIAS, SS
    BALL, WS
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (02): : 179 - 184
  • [6] FAST MRI WITH T2-WEIGHTED SPIN-ECHO SEQUENCES BY VARYING THE FLIP ANGLE
    SCHUBEUS, P
    SANDER, B
    SCHORNER, W
    DEIMLING, M
    TOSCH, U
    FELIX, R
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 155 (03): : 272 - 276
  • [7] T2-weighted MRI for the assessment of joint effusion: Comparative study of conventional spin-echo and fast spin-echo sequences
    Mori, S
    Kaneda, T
    Lee, K
    Kato, M
    Motohashi, J
    Ogura, I
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2004, 97 (06): : 768 - 774
  • [8] T2-WEIGHTED MR-IMAGING OF THE ABDOMEN - FAST SPIN-ECHO VS CONVENTIONAL SPIN-ECHO SEQUENCES
    CATASCA, JV
    MIROWITZ, SA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 61 - 67
  • [9] T2-weighted MR imaging of the uterus: Comparison of optimized fast spin-echo and HASTE sequences with conventional fast spin-echo sequences
    Gryspeerdt, S
    Van Hoe, L
    Bosmans, H
    Baert, AL
    Vergote, I
    Marchal, G
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 211 - 215
  • [10] T2-weighted three-dimensional turbo spin-echo MR of intracranial aneurysms
    Rubinstein, D
    Sandberg, EJ
    Breeze, RE
    Sheppard, SK
    Perkins, TG
    CajadeLaw, AG
    Simon, JH
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (10) : 1939 - 1943