3D isotropic T2-weighted fast spin echo (VISTA) versus 2D T2-weighted fast spin echo in evaluation of the calcaneofibular ligament in the oblique coronal plane

被引:14
|
作者
Park, H. J. [1 ]
Lee, S. Y. [1 ]
Choi, Y. J. [1 ]
Hong, H. P. [1 ]
Park, S. J. [2 ]
Park, J. H. [2 ]
Kim, E. [2 ]
机构
[1] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Sch Med, Dept Radiol, 108 Pyung Dong, Seoul 110746, South Korea
[2] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Sch Med, Dept Orthopaed Surg, Seoul, South Korea
关键词
MR ARTHROGRAPHY; 3.0; T; ANKLE; KNEE; SEQUENCE;
D O I
10.1016/j.crad.2016.09.023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To investigate whether the image quality of three-dimensional (3D) volume isotropic fast spin echo acquisition (VISTA) magnetic resonance imaging (MRI) of the calcaneofibular ligament (CFL) view is comparable to that of 2D fast spin echo T2-weighted images (2D T2 FSE) for the evaluation of the CFL, and whether 3D VISTA can replace 2D T2 FSE for the evaluation of CFL injuries. MATERIALS AND METHODS: This retrospective study included 76 patients who underwent ankle MRI with CFL views of both 2D T2 FSE MRI and 3D VISTA. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of both techniques were measured. The anatomical identification score and diagnostic performances were evaluated by two readers independently. The diagnostic performances of 3D VISTA and 2D T2 FSE were analysed by sensitivity, specificity, and accuracy for diagnosing CFL injury with reference standards of surgically or clinically confirmed diagnoses. Surgical correlation was performed in 29% of the patients, and clinical examination was used in those who did not have surgery (71%). RESULTS: The SNRs and CNRs of 3D VISTA were significantly higher than those of 2D T2 FSE. The anatomical identification scores on 3D VISTA were inferior to those on 2D T2 FSE, and the differences were statistically significant (p<0.05). There were no significant differences in diagnostic performance between the two sequences when diagnoses were classified as normal or abnormal. CONCLUSION: Although the image quality of 3D VISTA MRI of the CFL view is not equal to that of 2D T2 FSE for the anatomical evaluation of CFL, 3D VISTA has a diagnostic performance comparable to that of 2D T2 FSE for the diagnosis of CFL injuries. (C) 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:176.e1 / 176.e7
页数:7
相关论文
共 50 条
  • [1] The usefulness of the oblique coronal plane of three-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI in the evaluation of posterior cruciate ligament reconstruction with allograft: Comparison with the oblique coronal plane of two-dimensional fast spin-echo T2-weighted sequences
    Park, Hee Jin
    Lee, So Yeon
    Choi, Yoon Jung
    Choi, Seon Hyeong
    Kim, Mi Sung
    Ahn, Jin Hwan
    Park, Ji Yeon
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2019, 114 : 105 - 110
  • [2] Evaluation of Selective Bundle Injury to the Anterior Cruciate Ligament: T2-Weighted Fast Spin-Echo 3-T MRI With Reformatted 3D Oblique Isotropic (VISTA) Versus 2D Technique
    Lee, Jung Eun
    Park, Hee Jin
    Lee, So Yeon
    Ahn, Jin Hwan
    Park, Jai Hyung
    Park, Ji Yeon
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (05) : W308 - W316
  • [3] Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) ankle MRI versus two-dimensional fast spin-echo T2-weighted sequences for the evaluation of anterior talofibular ligament injury
    Park, H. J.
    Lee, S. Y.
    Park, N. H.
    Rho, M. H.
    Chung, E. C.
    Park, J. H.
    Park, S. J.
    [J]. CLINICAL RADIOLOGY, 2016, 71 (04) : 349 - 355
  • [4] Comparison of oblique coronal images in knee of three-dimensional isotropic T2-weighted turbo spin echo MRI versus two-dimensional fast spin echo T2-weighted sequences for evaluation of posterior cruciate ligament injury
    Park, Hee J.
    Lee, So Y.
    Choi, Seon H.
    Ahn, Jin H.
    Park, Se J.
    Park, Jai H.
    Kim, Eugene
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1067):
  • [5] 3D T2-Weighted Spin Echo Imaging in the Breast
    Moran, Catherine J.
    Hargreaves, Brian A.
    Saranathan, Manojkumar
    Lipson, Jafi A.
    Kao, Jennifer
    Ikeda, Debra M.
    Daniel, Bruce L.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (02) : 332 - 338
  • [6] 3D T2-weighted fast spin-echo MRI sialography of the parotid gland
    S. Sartoretti-Schefer
    S. Kollias
    W. Wichmann
    A. Valavanis
    [J]. Neuroradiology, 1999, 41 : 46 - 51
  • [7] 3D T2-weighted fast spin-echo MRI sialography of the parotid gland
    Sartoretti-Schefer, S
    Kollias, S
    Wichmann, W
    Valavanis, A
    [J]. NEURORADIOLOGY, 1999, 41 (01) : 46 - 51
  • [8] Usefulness of the oblique view of three-dimensional isotropic T2-weighted fast spin-echo (VISTA) in the evaluation of anterior cruciate ligament reconstruction
    Yi, Jung Woo
    Park, Hee Jin
    Lee, So Yeon
    Rho, Myung Ho
    Chung, Eun Chul
    Kim, Mi Sung
    Park, Jai Hyung
    Park, Se Jin
    [J]. CLINICAL IMAGING, 2016, 40 (04) : 610 - 616
  • [9] COMPARISON OF T2-WEIGHTED SPIN-ECHO AND FAST SPIN-ECHO TECHNIQUES IN THE EVALUATION OF MYELINATION
    PRENGER, EC
    BECKETT, WW
    KOLLIAS, SS
    BALL, WS
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (02): : 179 - 184
  • [10] A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque
    Lv, Peng
    Dai, Yuanyuan
    Lin, Jiang
    Zhang, Weisheng
    Liu, Hao
    Liu, Hui
    Tang, Xiao
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (03): : 395 - 400