3D isotropic T2-weighted fast spin echo (VISTA) versus 2D T2-weighted fast spin echo in evaluation of the calcaneofibular ligament in the oblique coronal plane

被引:14
|
作者
Park, H. J. [1 ]
Lee, S. Y. [1 ]
Choi, Y. J. [1 ]
Hong, H. P. [1 ]
Park, S. J. [2 ]
Park, J. H. [2 ]
Kim, E. [2 ]
机构
[1] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Sch Med, Dept Radiol, 108 Pyung Dong, Seoul 110746, South Korea
[2] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Sch Med, Dept Orthopaed Surg, Seoul, South Korea
关键词
MR ARTHROGRAPHY; 3.0; T; ANKLE; KNEE; SEQUENCE;
D O I
10.1016/j.crad.2016.09.023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To investigate whether the image quality of three-dimensional (3D) volume isotropic fast spin echo acquisition (VISTA) magnetic resonance imaging (MRI) of the calcaneofibular ligament (CFL) view is comparable to that of 2D fast spin echo T2-weighted images (2D T2 FSE) for the evaluation of the CFL, and whether 3D VISTA can replace 2D T2 FSE for the evaluation of CFL injuries. MATERIALS AND METHODS: This retrospective study included 76 patients who underwent ankle MRI with CFL views of both 2D T2 FSE MRI and 3D VISTA. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of both techniques were measured. The anatomical identification score and diagnostic performances were evaluated by two readers independently. The diagnostic performances of 3D VISTA and 2D T2 FSE were analysed by sensitivity, specificity, and accuracy for diagnosing CFL injury with reference standards of surgically or clinically confirmed diagnoses. Surgical correlation was performed in 29% of the patients, and clinical examination was used in those who did not have surgery (71%). RESULTS: The SNRs and CNRs of 3D VISTA were significantly higher than those of 2D T2 FSE. The anatomical identification scores on 3D VISTA were inferior to those on 2D T2 FSE, and the differences were statistically significant (p<0.05). There were no significant differences in diagnostic performance between the two sequences when diagnoses were classified as normal or abnormal. CONCLUSION: Although the image quality of 3D VISTA MRI of the CFL view is not equal to that of 2D T2 FSE for the anatomical evaluation of CFL, 3D VISTA has a diagnostic performance comparable to that of 2D T2 FSE for the diagnosis of CFL injuries. (C) 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:176.e1 / 176.e7
页数:7
相关论文
共 50 条
  • [41] FAST SPIN-ECHO INVERSION-RECOVERY IMAGING VERSUS FAST T2-WEIGHTED SPIN-ECHO IMAGING IN BONE-MARROW ABNORMALITIES
    HILFIKER, P
    ZANETTI, M
    DEBATIN, JF
    MCKINNON, G
    HODLER, J
    [J]. INVESTIGATIVE RADIOLOGY, 1995, 30 (02) : 110 - 114
  • [42] Liver MR imaging: Comparison of respiratory triggered fast spin echo with T2-weighted spin-echo and inversion recovery
    Keogan, MT
    Spritzer, CE
    Paulson, EK
    Paine, SS
    Harris, L
    Dahlke, JL
    MacFall, JR
    [J]. ABDOMINAL IMAGING, 1996, 21 (05): : 433 - 439
  • [43] T2-weighted fast-spin echo MRI in patients with normal tension glaucoma (NTG)
    Tanino, T
    Mashima, Y
    Harashima, N
    Oshitari, K
    Oguchi, Y
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 121 - 121
  • [44] MR imaging of acoustic neuroma with high resolution fast spin echo T2-weighted sequence
    Soulie, D
    Cordoliani, YS
    Vignaud, J
    Cosnard, G
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1997, 24 (01) : 61 - 65
  • [45] Uterine Tumors: Comparison of 3D versus 2D T2-weighted Turbo Spin-Echo MR Imaging at 3.0 T-Initial Experience
    Hori, Masatoshi
    Kim, Tonsok
    Onishi, Hiromitsu
    Ueguchi, Takashi
    Tatsumi, Mitsuaki
    Nakamoto, Atsushi
    Tsuboyama, Takahiro
    Tomoda, Kaname
    Tomiyama, Noriyuki
    [J]. RADIOLOGY, 2011, 258 (01) : 154 - 163
  • [46] MR cholangiopancreatography: value of axial and coronal fast Spin-Echo fat-suppressed T2-weighted sequences
    Boraschi, P
    Braccini, G
    Gigoni, R
    Geloni, M
    Perri, G
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1999, 32 (03) : 171 - 181
  • [47] T2-weighted breathold imaging of the liver: a quantitative and qualitative comparison of fast spin echo and half Fourier single shot fast spin echo imaging
    Thomas K. Helmberger
    Julia Schröder
    Nicolaus Holzknecht
    Michaela Gregor
    Andreas Heuck
    Rainer Petsch
    Maximilian F. Reiser
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 1999, 9 : 42 - 51
  • [48] T2-weighted MR imaging of the uterus: Comparison of optimized fast spin-echo and HASTE sequences with conventional fast spin-echo sequences
    Gryspeerdt, S
    Van Hoe, L
    Bosmans, H
    Baert, AL
    Vergote, I
    Marchal, G
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 211 - 215
  • [49] T2-weighted breathold imaging of the liver: a quantitative and qualitative comparison of fast spin echo and half Fourier single shot fast spin echo imaging
    Helmberger, Thomas K.
    Schroeder, Julia
    Holzknecht, Nicolaus
    Gregor, Michaela
    Heuck, Andreas
    Petsch, Rainer
    Reiser, Maximilian F.
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1999, 9 (1-2) : 42 - 51
  • [50] Comparison of T2-weighted fast spin-echo and spin-echo MR sequences in the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Accardi, M
    Pappalardo, S
    Sarno, C
    DeMaria, M
    [J]. RIVISTA DI NEURORADIOLOGIA, 1997, 10 : 233 - 235