T2-weighted breathold imaging of the liver: a quantitative and qualitative comparison of fast spin echo and half Fourier single shot fast spin echo imaging

被引:0
|
作者
Helmberger, Thomas K. [1 ]
Schroeder, Julia [1 ]
Holzknecht, Nicolaus [1 ]
Gregor, Michaela [1 ]
Heuck, Andreas [1 ]
Petsch, Rainer [2 ]
Reiser, Maximilian F. [1 ]
机构
[1] Univ Munich, Klinikum Grosshadern, Inst Diagnost Radiol, D-81366 Munich, Germany
[2] Siemens Med Engn, Erlangen, Germany
关键词
Liver neoplasms; MR pulse sequences; T2-weighted rapid imaging; T2-weighted half-Fourier imaging;
D O I
10.1007/BF02634591
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The imaging characteristics of two EPI-hybrid breath-hold sequences, T2-weighted fast spin-echo [FSE, effective echo time (TE(eff),) 138 ms] and half Fourier single shot turbo spin-echo (HASTE, TE(eff) 60 ms), were compared in hepatic imaging. A total of 111 patients with suspected hepatic disease were studied at 1.5 Tesla using a body phase-array coil. The signal-to-noise (S/N) and contrast-to-noise (C/N) ratios for organs and lesions were calculated and quantitatively compared. Organ delineation, visualization of anatomical structures and pathological lesions, artifacts, and total image quality were qualitatively assessed and statistically compared. The final diagnoses were metastases from colorectal, breast, and pancreatic cancer in 23/111, hepatocellular carcinoma in 15/111, cysts in 19/111, hemangiomas in 9/111. several other lesions in 7/111, and no lesions in 38/111 of the cases. A total of 139 lesion in 73% of the patients were seen while 85% of the lesions were at least 1.5 cm in size. Regarding S/Ns HASTE was significantly (P < 0.03) superior to FSE with only minor (P > 0.05) differences in C/Ns between the two sequences for anatomical and pathological structures. HASTE demonstrated in almost all (97.3%) of the cases no artifacts, while on fast SE imaging moderate to minor artifacts were present in 23.5-51.7% of the cases. The overall image quality and diagnostic confidence was rated significantly higher (good 43.2%, excellent 53.2%,) for HASTE than for last SE imaging (good 44.8%, excellent 17.6%). Providing comparable C/Ns for anatomical and pathological structures, breatheld HASTE imaging proved to be superior to fast SE in T2-weighted imaging of the upper abdomen regarding general image quality, and, with adequate technical prerequisites, may be a suitable substitute of fast T2-imaging techniques. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:42 / 51
页数:10
相关论文
共 50 条
  • [1] T2-weighted breathold imaging of the liver: a quantitative and qualitative comparison of fast spin echo and half Fourier single shot fast spin echo imaging
    Thomas K. Helmberger
    Julia Schröder
    Nicolaus Holzknecht
    Michaela Gregor
    Andreas Heuck
    Rainer Petsch
    Maximilian F. Reiser
    Magnetic Resonance Materials in Physics, Biology and Medicine, 1999, 9 : 42 - 51
  • [2] Multi-shot echo-planar Flair imaging of brain tumors: comparison of spin-echo T1-weighted, fast spin-echo T2-weighted, and fast spin-echo Flair imaging
    Tomura, N
    Kato, K
    Takahashi, S
    Sashi, R
    Izumi, J
    Narita, K
    Watarai, J
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (02) : 65 - 72
  • [3] Ultrafast T2-weighted imaging of the abdomen and pelvis: Use of single shot fast spin-echo imaging
    Tang, Y
    Yamashita, Y
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (02): : 384 - 390
  • [4] Liver MR imaging: Comparison of respiratory triggered fast spin echo with T2-weighted spin-echo and inversion recovery
    Keogan, MT
    Spritzer, CE
    Paulson, EK
    Paine, SS
    Harris, L
    Dahlke, JL
    MacFall, JR
    ABDOMINAL IMAGING, 1996, 21 (05): : 433 - 439
  • [5] T2-weighted fast spin-echo MR imaging of liver.
    Mirowitz, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 263 - 264
  • [6] Single breath-hold T2-weighted MR imaging of the liver: Value of single-shot fast spin-echo and multishot spin-echo echoplanar imaging
    Hori, M
    Murakami, T
    Kim, T
    Kanematsu, M
    Tsuda, K
    Takahashi, S
    Takamura, M
    Hoshi, H
    Nakamura, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (05) : 1423 - 1431
  • [7] Comparison of T2-weighted MRI single-shot fast spin echo and fast spin echo sequences in focal hepatic lesion detection
    Gras, E
    Aube, C
    Tanguy, J
    Oberti, F
    Burtin, P
    Caron, C
    RADIOLOGY, 2000, 217 : 168 - 169
  • [8] Dual-echo breathhold T2-weighted fast spin echo MR imaging of liver lesions
    Rydberg, JN
    Tervonen, OA
    Rydberg, DB
    Lomas, DJ
    Ehman, RL
    Riederer, SJ
    MAGNETIC RESONANCE IMAGING, 2000, 18 (02) : 117 - 124
  • [9] T2-weighted IDEAL fast spin echo imaging of the brachial plexus: comparison with STIR
    Tomura, Noriaki
    Saginoya, Toshiyuki
    Kokubun, Mika
    Tsuchiya, Mario
    Yamamoto, Teiji
    ACTA RADIOLOGICA, 2015, 56 (10) : 1242 - 1247
  • [10] Liver T2-weighted MR imaging: Comparison of fast and conventional half-Fourier single-shot turbo spin-echo, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences
    Tang, Y
    Yamashita, Y
    Namimoto, T
    Abe, Y
    Takahashi, M
    RADIOLOGY, 1997, 203 (03) : 766 - 772