Three-dimensional isotropic T2-weighted cervical MRI at 3 T: Comparison with two-dimensional T2-weighted sequences

被引:50
|
作者
Kwon, J. W. [1 ]
Yoon, Y. C.
Choi, S. -H.
机构
[1] Sungkyunkwan Univ, Sch Med, Dept Radiol, Samsung Med Ctr, Seoul 135710, South Korea
关键词
MAGNETIC-SUSCEPTIBILITY ARTIFACTS; GRADIENT-RECALLED ECHO; IMAGE QUALITY; SPIN-ECHO; EXPERIENCE; RESOLUTION; CARTILAGE; CONTRAST; 3-TESLA; ANKLE;
D O I
10.1016/j.crad.2011.06.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To compare three-dimensional (3D) isotropic T2-weighted magnetic resonance imaging (MRI) sequences and reformation with two-dimensional (2D) T2-weighted sequences regarding image quality of the cervical spine at 3 T. MATERIALS AND METHODS: A phantom study was performed using a water-filled cylinder. The signal-to-noise and image homogeneity were evaluated. Fourteen (n = 14) volunteers were examined at 3 T using 3D isotropic T2-weighted sagittal and conventional 2D T2-weighted sagittal, axial, and oblique sagittal MRI. Multiplanar reformation (MPR) of the 3D T2-weighted sagittal dataset was performed simultaneously with image evaluation. In addition to artefact assessment, the visibility of anatomical structures in the 3D and 2D sequences was qualitatively assessed by two radiologists independently. Cohen's kappa and Wilcoxon signed rank test were used for the statistical analysis. RESULT: The 3D isotropic T2-weighted sequence resulted in the highest signal-to-noise ratio (SNR) and lowest non-uniformity (NU) among the sequences in the phantom study. Quantitative evaluation revealed lower NU values of the cerebrospinal fluid (CSF) and muscles in 2D T2-weighted sagittal sequences compared to the 3D volume isotropic turbo spin-echo acquisition (VISTA) sequence. The other NU values revealed no statistically significant difference between the 2D turbo spin-echo (TSE) and 3D VISTA sequences (0.059 < p < 0.959). 3D VISTA images showed significantly fewer CSF flow artefacts (p < 0.001) and better delineated intradural nerve rootlets (p = 0.001) and neural foramina (p = 0.016) compared to 2D sequences. CONCLUSION: A 3D 12 weighted sequence is superior to conventional 2D sequences for the delineation of intradural nerve rootlets and neural foramina and is less affected by CSF flow artefacts. (C) 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:106 / 113
页数:8
相关论文
共 50 条
  • [1] Detection of focal hepatic lesions with 3-T MRI: comparison of two-dimensional and three-dimensional T2-weighted sequences
    Haruo Watanabe
    Masayuki Kanematsu
    Satoshi Goshima
    Hiroshi Kondo
    Kimihiro Kajita
    Hiroshi Kawada
    Yoshifumi Noda
    Noriyuki Moriyama
    [J]. Japanese Journal of Radiology, 2012, 30 : 721 - 728
  • [2] Detection of focal hepatic lesions with 3-T MRI: comparison of two-dimensional and three-dimensional T2-weighted sequences
    Watanabe, Haruo
    Kanematsu, Masayuki
    Goshima, Satoshi
    Kondo, Hiroshi
    Kajita, Kimihiro
    Kawada, Hiroshi
    Noda, Yoshifumi
    Moriyama, Noriyuki
    [J]. JAPANESE JOURNAL OF RADIOLOGY, 2012, 30 (09) : 721 - 728
  • [3] Comparison of oblique coronal images in knee of three-dimensional isotropic T2-weighted turbo spin echo MRI versus two-dimensional fast spin echo T2-weighted sequences for evaluation of posterior cruciate ligament injury
    Park, Hee J.
    Lee, So Y.
    Choi, Seon H.
    Ahn, Jin H.
    Park, Se J.
    Park, Jai H.
    Kim, Eugene
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1067):
  • [4] Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) ankle MRI versus two-dimensional fast spin-echo T2-weighted sequences for the evaluation of anterior talofibular ligament injury
    Park, H. J.
    Lee, S. Y.
    Park, N. H.
    Rho, M. H.
    Chung, E. C.
    Park, J. H.
    Park, S. J.
    [J]. CLINICAL RADIOLOGY, 2016, 71 (04) : 349 - 355
  • [5] Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI at 3.0T in the evaluation of the anterior cruciate ligament injury with additional views: comparison with two-dimensional fast spin-echo T2-weighted sequences
    Park, Hee Jin
    Lee, So Yeon
    Park, Noh Hyuck
    Ahn, Jin Hwan
    Chung, Eun Chul
    Kim, Sung Jun
    Cha, Jang Gyu
    [J]. ACTA RADIOLOGICA, 2016, 57 (11) : 1372 - 1379
  • [6] Application of a three-dimensional T2-weighted sequence for neuronavigation
    Gralla, J
    Guzman, R
    Brekenfeld, C
    Remonda, L
    Kiefer, C
    [J]. 12TH EUROPEAN CONGRESS OF NEUROSURGERY (EANS), PROCEEDINGS, 2003, : 451 - 454
  • [7] T2-Weighted Liver MRI Using the MultiVane Technique at 3T: Comparison with Conventional T2-Weighted MRI
    Kang, Kyung A.
    Kim, Young Kon
    Kim, EunJu
    Jeong, Woo Kyoung
    Choi, Dongil
    Lee, Won Jae
    Jung, Sin-Ho
    Baek, Sun-Young
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (05) : 1038 - 1046
  • [8] Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences
    Murat Ucar
    Nil Tokgoz
    Cagri Damar
    Ayse Gul Alimli
    Fatih Oncu
    [J]. Japanese Journal of Radiology, 2015, 33 : 94 - 101
  • [9] Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences
    Ucar, Murat
    Tokgoz, Nil
    Damar, Cagri
    Alimli, Ayse Gul
    Oncu, Fatih
    [J]. JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (02) : 94 - 101
  • [10] Quality comparison between three-dimensional T2-weighted SPACE and two-dimensional T2-weighted turbo spin echo magnetic resonance images for the brachytherapy planning evaluation of prostate and periprostatic anatomy
    Bathala, Tharakeswara K.
    Venkatesan, Aradhana M.
    Ma, Jingfei
    Bhosale, Priyadarshini
    Wei, Wei
    Kudchadker, Rajat J.
    Wang, Jihong
    Anscher, Mitchell S.
    Tang, Chad
    Bruno, Teresa L.
    Frank, Steven J.
    Szklaruk, Janio
    [J]. BRACHYTHERAPY, 2020, 19 (04) : 484 - 490