A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque

被引:0
|
作者
Peng Lv
Yuanyuan Dai
Jiang Lin
Weisheng Zhang
Hao Liu
Hui Liu
Xiao Tang
机构
[1] Fudan University and Shanghai Institute of Medical Imaging,Department of Radiology, Zhongshan Hospital
[2] First Affiliated Hospital of Dalian Medical University,Department of Radiology
[3] Fudan University,Department of Vascular Surgery, Zhongshan Hospital
关键词
Carotid artery; Plaque; Atherosclerosis; Magnetic resonance imaging;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to compare 3D T2-weighted sampling perfection with application optimized contrast using different flip angle evolutions (T2w SPACE) with conventional 2D T2w turbo-spin echo (TSE) in plaque imaging of carotid artery. 45 patients underwent 3.0-T MRI for carotid arteries imaging. MR sequences included T2w SPACE, T2w TSE, Time of flight (TOF) and T1-weighted (T1w) TSE. The signal intensity of intra-plaque hemorrhage (IPH), lipid-rich necrotic core (LRNC), and loose matrix (LM) were measured and their contrast ratios (CRs) against adjacent muscle were calculated. CRs from T2w SPACE and T2w TSE were compared to each other. CRs of LM, LRNC, and IPH measured on T2w SPACE were 1.74–3.04 (2.44), 0.98–1.66 (1.39), and 1.91–2.93 (2.51), respectively. CRs of LM, LRNC, and IPH on T2w TSE were 1.97–3.41 (2.44), 1.18–1.73 (1.43), and 2.26–3.75 (2.26), respectively. There was no significant difference of CR of the carotid plaques between T2w SPACE and T2w TSE (p = 0.455). Markedly significant differences of CRs were found between LM and LRNC (p < 0.001), and between LRNC and IPH (p < 0.001) on T2w SPACE and T2w TSE. T2w SPACE was comparable with conventional T2w TSE in characterization of carotid plaque.
引用
收藏
页码:395 / 400
页数:5
相关论文
共 50 条
  • [1] A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque
    Lv, Peng
    Dai, Yuanyuan
    Lin, Jiang
    Zhang, Weisheng
    Liu, Hao
    Liu, Hui
    Tang, Xiao
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (03): : 395 - 400
  • [2] Magnetic resonance imaging of the cervical spine: comparison of 2D T2-weighted turbo spin echo, 2D T2*weighted gradient-recalled echo and 3D T2-weighted variable flip-angle turbo spin echo sequences
    T. Meindl
    S. Wirth
    S. Weckbach
    O. Dietrich
    M. Reiser
    S. O. Schoenberg
    [J]. European Radiology, 2009, 19 : 713 - 721
  • [3] Magnetic resonance imaging of the cervical spine: comparison of 2D T2-weighted turbo spin echo, 2D T2*weighted gradient-recalled echo and 3D T2-weighted variable flip-angle turbo spin echo sequences
    Meindl, T.
    Wirth, S.
    Weckbach, S.
    Dietrich, O.
    Reiser, M.
    Schoenberg, S. O.
    [J]. EUROPEAN RADIOLOGY, 2009, 19 (03) : 713 - 721
  • [4] Prostate Cancer: Comparison of 3D T2-Weighted With Conventional 2D T2-Weighted Imaging for Image Quality and Tumor Detection
    Rosenkrantz, Andrew B.
    Neil, Jeffry
    Kong, Xiangtian
    Melamed, Jonathan
    Babb, James S.
    Taneja, Samir S.
    Taouli, Bachir
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (02) : 446 - 452
  • [5] 3D T2-Weighted Spin Echo Imaging in the Breast
    Moran, Catherine J.
    Hargreaves, Brian A.
    Saranathan, Manojkumar
    Lipson, Jafi A.
    Kao, Jennifer
    Ikeda, Debra M.
    Daniel, Bruce L.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (02) : 332 - 338
  • [6] Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences
    Murat Ucar
    Nil Tokgoz
    Cagri Damar
    Ayse Gul Alimli
    Fatih Oncu
    [J]. Japanese Journal of Radiology, 2015, 33 : 94 - 101
  • [7] Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences
    Ucar, Murat
    Tokgoz, Nil
    Damar, Cagri
    Alimli, Ayse Gul
    Oncu, Fatih
    [J]. JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (02) : 94 - 101
  • [8] 3D isotropic T2-weighted fast spin echo (VISTA) versus 2D T2-weighted fast spin echo in evaluation of the calcaneofibular ligament in the oblique coronal plane
    Park, H. J.
    Lee, S. Y.
    Choi, Y. J.
    Hong, H. P.
    Park, S. J.
    Park, J. H.
    Kim, E.
    [J]. CLINICAL RADIOLOGY, 2017, 72 (02) : 176.e1 - 176.e7
  • [9] Uterine Tumors: Comparison of 3D versus 2D T2-weighted Turbo Spin-Echo MR Imaging at 3.0 T-Initial Experience
    Hori, Masatoshi
    Kim, Tonsok
    Onishi, Hiromitsu
    Ueguchi, Takashi
    Tatsumi, Mitsuaki
    Nakamoto, Atsushi
    Tsuboyama, Takahiro
    Tomoda, Kaname
    Tomiyama, Noriyuki
    [J]. RADIOLOGY, 2011, 258 (01) : 154 - 163
  • [10] Comparison of T2-Weighted 3D-Space and T2-Weighted 2D-TSE Sequences in Lumbar Spine MR Imaging
    Qurat-ul-Ain
    Nadeem, Syed Farrukh
    Mirza, Tariq Mahmood
    Shafiq, Mazhar
    Batool, Zahida
    Khadijah-tul-Kubra
    [J]. ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN, 2023, 29 (04): : 361 - 366