A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque

被引:0
|
作者
Peng Lv
Yuanyuan Dai
Jiang Lin
Weisheng Zhang
Hao Liu
Hui Liu
Xiao Tang
机构
[1] Fudan University and Shanghai Institute of Medical Imaging,Department of Radiology, Zhongshan Hospital
[2] First Affiliated Hospital of Dalian Medical University,Department of Radiology
[3] Fudan University,Department of Vascular Surgery, Zhongshan Hospital
关键词
Carotid artery; Plaque; Atherosclerosis; Magnetic resonance imaging;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to compare 3D T2-weighted sampling perfection with application optimized contrast using different flip angle evolutions (T2w SPACE) with conventional 2D T2w turbo-spin echo (TSE) in plaque imaging of carotid artery. 45 patients underwent 3.0-T MRI for carotid arteries imaging. MR sequences included T2w SPACE, T2w TSE, Time of flight (TOF) and T1-weighted (T1w) TSE. The signal intensity of intra-plaque hemorrhage (IPH), lipid-rich necrotic core (LRNC), and loose matrix (LM) were measured and their contrast ratios (CRs) against adjacent muscle were calculated. CRs from T2w SPACE and T2w TSE were compared to each other. CRs of LM, LRNC, and IPH measured on T2w SPACE were 1.74–3.04 (2.44), 0.98–1.66 (1.39), and 1.91–2.93 (2.51), respectively. CRs of LM, LRNC, and IPH on T2w TSE were 1.97–3.41 (2.44), 1.18–1.73 (1.43), and 2.26–3.75 (2.26), respectively. There was no significant difference of CR of the carotid plaques between T2w SPACE and T2w TSE (p = 0.455). Markedly significant differences of CRs were found between LM and LRNC (p < 0.001), and between LRNC and IPH (p < 0.001) on T2w SPACE and T2w TSE. T2w SPACE was comparable with conventional T2w TSE in characterization of carotid plaque.
引用
收藏
页码:395 / 400
页数:5
相关论文
共 50 条
  • [21] Comparison of 3D FLAIR, 2D FLAIR, and 2D T2-Weighted MR Imaging of Brain Stem Anatomy
    Kitajima, M.
    Hirai, T.
    Shigematsu, Y.
    Uetani, H.
    Iwashita, K.
    Morita, K.
    Komi, M.
    Yamashita, Y.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (05) : 922 - 927
  • [22] An efficient 3D stack-of-stars turbo spin echo pulse sequence for simultaneous T2-weighted imaging and T2 mapping
    Keerthivasan, Mahesh Bharath
    Saranathan, Manojkumar
    Johnson, Kevin
    Fu, Zhiyang
    Weinkauf, Craig C.
    Martin, Diego R.
    Bilgin, Ali
    Altbach, Maria I.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (01) : 326 - 341
  • [23] Evaluation of diagnostic value and T2-weighted three-dimensional isotropic turbo spin-echo (3D-SPACE) image quality in comparison with T2-weighted two-dimensional turbo spin-echo (2D-TSE) sequences in lumbar spine MR imaging
    Hossein, Jomleh
    Fariborz, Faeghi
    Mehrnaz, Rasteh
    Babak, Rafiei
    [J]. EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2019, 6 : 36 - 41
  • [24] Accelerated 3D high-resolution T2-weighted breast MRI with deep learning constrained compressed sensing, comparison with conventional T2-weighted sequence on 3.0 T
    Yang, Fan
    Pan, Xuelin
    Zhu, Ke
    Xiao, Yitian
    Yue, Xun
    Peng, Pengfei
    Zhang, Xiaoyong
    Huang, Juan
    Chen, Jie
    Yuan, Yuan
    Sun, Jiayu
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2022, 156
  • [25] Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT
    G. A. Krombach
    T. Schmitz-Rode
    P. Haage
    E. DiMartino
    A. Prescher
    S. Kinzel
    R. W. Günther
    [J]. Neuroradiology, 2004, 46 : 326 - 331
  • [26] Semicircular canal dehiscence:: comparison of T2-weighted turbo spin-echo MRI and CT
    Krombach, GA
    Schmitz-Rode, T
    Haage, P
    DiMartino, E
    Prescher, A
    Kinzel, S
    Günther, RW
    [J]. NEURORADIOLOGY, 2004, 46 (04) : 326 - 331
  • [27] Comparison of multishot turbo spin echo and HASTE sequences for T2-weighted MRI of liver lesions
    Yu, JS
    Kim, KW
    Kim, YH
    Jeong, EK
    Chien, D
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (05): : 1079 - 1084
  • [28] MRI of the regions of inner ear and cerebellopontine angle using a 3D T-2-weighted turbo spin-echo sequence: Comparison with conventional 2D T-2-weighted turbo spin-echo sequences and T-1-weighted spin-echo sequences.
    Czerny, C
    Trattnig, S
    Baumgartner, WD
    Gstottner, W
    Imhof, H
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (04): : 377 - 383
  • [29] High-resolution 3D T2-weighted fast spin echo: new applications in the orbit
    Simon, EM
    McCaffery, S
    Rowley, HA
    Fischbein, NJ
    Shimikawa, A
    O'Brien, JM
    [J]. NEURORADIOLOGY, 2003, 45 (07) : 489 - 492
  • [30] High-resolution 3D T2-weighted fast spin echo: new applications in the orbit
    Erin M. Simon
    Sharon McCaffery
    Howard A. Rowley
    Nancy J. Fischbein
    Ann Shimikawa
    Joan M. O'Brien
    [J]. Neuroradiology, 2003, 45 : 489 - 492