Lens of the eye dose calculation for neuro-interventional procedures and CBCT scans of the head

被引:7
|
作者
Xiong, Zhenyu [1 ]
Vijayan, Sarath [1 ]
Rana, Vijay [1 ]
Jain, Amit [1 ]
Rudin, Stephen [1 ]
Bednarek, Daniel R. [1 ]
机构
[1] Univ Buffalo, Toshiba Stroke & Vasc Res Ctr, Buffalo, NY USA
关键词
lens dose; Monte Carlo; EGSnrc; DTS; CBCT; neuro-interventional procedure; RADIATION;
D O I
10.1117/12.2216504
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The aim of this work is to develop a method to calculate lens dose for fluoroscopically-guided neuro-interventional procedures and for CBCT scans of the head. EGSnrc Monte Carlo software is used to determine the dose to the lens of the eye for the projection geometry and exposure parameters used in these procedures. This information is provided by a digital CAN bus on the Toshiba Infinix C-Arm system which is saved in a log file by the real-time skin-dose tracking system (DTS) we previously developed. The x-ray beam spectra on this machine were simulated using BEAMnrc. These spectra were compared to those determined by SpekCalc and validated through measured percent-depth-dose (PDD) curves and half-value-layer (HVL) measurements. We simulated CBCT procedures in DOSXYZnrc for a CTDI head phantom and compared the surface dose distribution with that measured with Gafchromic film, and also for an SK150 head phantom and compared the lens dose with that measured with an ionization chamber. Both methods demonstrated good agreement. Organ dose calculated for a simulated neuro-interventional-procedure using DOSXYZnrc with the Zubal CT voxel phantom agreed within 10% with that calculated by PCXMC code for most organs. To calculate the lens dose in a neuro-interventional procedure, we developed a library of normalized lens dose values for different projection angles and kVp's. The total lens dose is then calculated by summing the values over all beam projections and can be included on the DTS report at the end of the procedure.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Assessment of Eye Lens Dose Reduction When Using Lateral Lead Shields on the Patient's Head during Neurointerventional Fluoroscopic Procedures and Cone-beam Computed Tomography (CBCT) Scans
    Xiong, Zhenyu
    Rudin, Stephen
    Bednarek, Daniel R.
    HEALTH PHYSICS, 2020, 119 (03): : 289 - 296
  • [32] Occupational eye dose in interventional cardiology procedures
    Haga, Yoshihiro
    Chida, Koichi
    Kaga, Yuji
    Sota, Masahiro
    Meguro, Taiichiro
    Zuguchi, Masayuki
    SCIENTIFIC REPORTS, 2017, 7
  • [33] Occupational eye dose in interventional cardiology procedures
    Yoshihiro Haga
    Koichi Chida
    Yuji Kaga
    Masahiro Sota
    Taiichiro Meguro
    Masayuki Zuguchi
    Scientific Reports, 7
  • [34] DNA damage and gene expression changes in patients exposed to low-dose X-radiation during neuro-interventional radiology procedures
    Visweswaran, Shangamithra
    Joseph, Santhosh
    Hegde, Vinay S.
    Annalakshmi, O.
    Jose, M. T.
    Perumal, Venkatachalam
    MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2019, 844 : 54 - 61
  • [35] Assessment of effective dose and dose to the lens of the eye for the interventional cardiologist
    Lie, Oydis Ostbye
    Paulsen, Gudrun Uthaug
    Wohni, Tor
    RADIATION PROTECTION DOSIMETRY, 2008, 132 (03) : 313 - 318
  • [36] Aristotle wires for cannulating target vessels in paediatric neuro-interventional procedures: A case-control study
    Bhatia, K. D.
    Blane, T.
    Giarola, B.
    Vedamuthu, J.
    Do Nascimento, V. Carraro
    Kim, Y-j
    Olsson, G.
    Dexter, M.
    NEURORADIOLOGY JOURNAL, 2025,
  • [37] Feasibility of Direct Proton Dose Calculation On CBCT Scans in Esophageal Cancer
    Defraene, G.
    Thomas, M.
    De Roover, R.
    Michiels, S.
    Depuydt, T.
    Sterpin, E.
    Haustermans, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E618 - E619
  • [38] Dosimetry of Occupational Eye Lens Dose Using a Novel Direct Eye Dosimeter, DOSIRIS, during Interventional Radiology Procedures
    Hirakawa, Masakazu
    Nakatake, Hiroshi
    Tsuruta, Satoru
    Matsuura, Shuji
    Motomura, Yuushi
    Hiraki, Yoshiki
    Mimori, Koshi
    Ishigami, Kousei
    INTERVENTIONAL RADIOLOGY, 2022, 7 (02) : 40 - 43
  • [39] Cataract risk of neuro-interventional procedures: a nationwide population-based matched-cohort study
    Cheng, K. L.
    Huang, J. Y.
    Su, C. L.
    Tung, K. C.
    Chiou, J. Y.
    CLINICAL RADIOLOGY, 2018, 73 (09) : 836.e17 - 836.e22
  • [40] Evaluation of skin-dose contribution from a new high-definition image receptor mode during neuro-interventional procedures using the Dose Tracking System
    Troville, J.
    Rudin, S.
    Bednarek, D. R.
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948