Occupational eye dose in interventional cardiology procedures

被引:0
|
作者
Yoshihiro Haga
Koichi Chida
Yuji Kaga
Masahiro Sota
Taiichiro Meguro
Masayuki Zuguchi
机构
[1] Tohoku University Graduate School of Medicine,Department of Radiological Technology, Faculty of Health Sciences
[2] Sendai Kousei Hospital,Department of Radiology
[3] International Research Institute of Disaster Science,Department of Radiation Disaster Medicine
[4] Tohoku University,Department of Cardiovascular Medicine
[5] Sendai Kousei Hospital,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
It is important to measure the radiation dose [3-mm dose equivalent, Hp(3)] in the eye. This study was to determine the current occupational radiation eye dose of staff conducting interventional cardiology procedures, using a novel direct eye dosimeter. We measured the occupational eye dose [Hp(3)] in physicians and nurses in a catheterization laboratory for 6-months. The eye doses [Hp(3)] of 12 physicians (9 with Pb glasses, 3 without), and 11 nurses were recorded using a novel direct eye dosimeter, the DOSIRISTM. We placed dosimeters above and under the glasses. We also estimated the eye dose [0.07-mm dose equivalent] using a neck personal dosimeter. The eye doses among interventional staff ranked in the following order: physicians without Pb glasses > physicians with Pb glasses > nurses. The shielding effect of the glasses (0.07-mm Pb) in a clinical setting was approximately 60%. In physicians who do not wear Pb glasses, the eye dose may exceed the new regulatory limit for IR staff. We found good correlations between the neck dosimeter dose and eye dosimeter dose (inside or outside glasses, R2 = 0.93 and R2 = 0.86, respectively) in physicians. We recommend that interventional physicians use an eye dosimeter for correct evaluation of the lens dose.
引用
收藏
相关论文
共 50 条
  • [1] Occupational eye dose in interventional cardiology procedures
    Haga, Yoshihiro
    Chida, Koichi
    Kaga, Yuji
    Sota, Masahiro
    Meguro, Taiichiro
    Zuguchi, Masayuki
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [2] Occupational eye dose correlation with neck dose and patient-related quantities in interventional cardiology procedures
    Ishii, Hiroki
    Chida, Koichi
    Satsurai, Ko
    Haga, Yoshihiro
    Kaga, Yuji
    Abe, Mitsuya
    Inaba, Yohei
    Zuguchi, Masayuki
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2022, 15 (01) : 54 - 62
  • [3] Occupational eye dose correlation with neck dose and patient-related quantities in interventional cardiology procedures
    Hiroki Ishii
    Koichi Chida
    Ko Satsurai
    Yoshihiro Haga
    Yuji Kaga
    Mitsuya Abe
    Yohei Inaba
    Masayuki Zuguchi
    [J]. Radiological Physics and Technology, 2022, 15 : 54 - 62
  • [4] Occupational dose constraints in interventional cardiology procedures: the DIMOND approach
    Tsapaki, V
    Kottou, S
    Vano, E
    Komppa, T
    Padovani, R
    Dowling, A
    Molfetas, M
    Neofotistou, V
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (06): : 997 - 1005
  • [5] Occupational radiation dose and protection to the eye lens for interventional cardiology operators
    Lian, Meng-En
    Wu, Guan-Yi
    Chao, Min-Fang
    Wang, Chong-Sheng
    Miao, Hsiao-Chien
    Tsai, Ming-Sung
    Hsieh, Mu-Yang
    Chen, Yeh-Peng
    Chu, Chun-Yuan
    Chang, Szu-Li
    Tsai, Hui-Yu
    [J]. RADIATION MEASUREMENTS, 2022, 154
  • [6] EYE LENS DOSE IN INTERVENTIONAL CARDIOLOGY
    Principi, S.
    Delgado Soler, C.
    Ginjaume, M.
    Beltran Vilagrasa, M.
    Rovira Escutia, J. J.
    Duch, M. A.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 289 - 293
  • [7] OCCUPATIONAL DOSE ASSESSMENT IN INTERVENTIONAL CARDIOLOGY IN SERBIA
    Kaljevic, J.
    Ciraj-Bjelac, O.
    Stankovic, J.
    Arandjic, D.
    Bozovic, P.
    Antic, V.
    [J]. RADIATION PROTECTION DOSIMETRY, 2016, 170 (1-4) : 279 - 283
  • [8] Occupational dose measurement in interventional cardiology practice
    Wickramasinghe, Sachini Udara
    Ramanathan, Vijitha
    Sarasanandarajah, Sivananthan
    De Zoyza, Manjuka
    Paranamana, Roshan
    [J]. RADIATION PROTECTION DOSIMETRY, 2024, 200 (07) : 629 - 639
  • [9] Assessment of the occupational eye lens dose for clinical staff in interventional radiology, cardiology and neuroradiology
    Omar, Artur
    Kadesjo, Nils
    Palmgren, Charlotta
    Marteinsdottir, Maria
    Segerdahl, Tony
    Fransson, Annette
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2017, 37 (01) : 145 - 159
  • [10] Occupational Dose in Interventional Radiology Procedures
    Chida, Koichi
    Kaga, Yuji
    Haga, Yoshihiro
    Kataoka, Nozomi
    Kumasaka, Eriko
    Meguro, Taiichiro
    Zuguchi, Masayuki
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (01) : 138 - 141