Occupational dose measurement in interventional cardiology practice

被引:0
|
作者
Wickramasinghe, Sachini Udara [1 ]
Ramanathan, Vijitha [1 ]
Sarasanandarajah, Sivananthan [2 ,3 ]
De Zoyza, Manjuka [4 ]
Paranamana, Roshan [4 ]
机构
[1] Gen Sir John Kotelawala Def Univ, Fac Allied Hlth Sci, Ratmalana, Sri Lanka
[2] Peter MacCallum Canc Ctr, Dept Phys Sci, Melbourne, Vic, Australia
[3] RMIT Univ, Sch Hlth & Biomed Sci, Melbourne, Vic, Australia
[4] Natl Hosp, Inst Cardiol, Colombo, Sri Lanka
关键词
RADIATION-EXPOSURE; RADIOLOGY; DOSIMETRY; STAFF; ALGORITHMS; SINGLE;
D O I
10.1093/rpd/ncae072
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ensuring the safety of healthcare workers in interventional cardiology necessitates effective monitoring of occupational radiation exposure. This study aims to assess the accuracy of the over-apron single dosimetric approach compared with double dosimetric methods and explore the relationship between under-apron and over-apron doses. This investigation showed that the prescribed annual dose constraint of 20 mSv year-1 was not exceeded by the maximum annual occupational doses determined by dosimetric algorithms, which were 0.13 +/- 0.02, 0.15 +/- 0.02 and 0.27 +/- 0.04 mSv, respectively. The study demonstrated excellent statistically significant correlations among single and double dosimetric algorithms and between direct under-apron and over-apron doses. Consequently, single dosimetric algorithms could effectively estimate doses for double dosimetric algorithms, highlighting the limited added value of under-apron measurements. These findings significantly impact the practice of interventional cardiology in Sri Lanka, playing a crucial role in enhancing radiation protection measures.
引用
收藏
页码:629 / 639
页数:11
相关论文
共 50 条
  • [1] Occupational eye dose in interventional cardiology procedures
    Haga, Yoshihiro
    Chida, Koichi
    Kaga, Yuji
    Sota, Masahiro
    Meguro, Taiichiro
    Zuguchi, Masayuki
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [2] OCCUPATIONAL DOSE ASSESSMENT IN INTERVENTIONAL CARDIOLOGY IN SERBIA
    Kaljevic, J.
    Ciraj-Bjelac, O.
    Stankovic, J.
    Arandjic, D.
    Bozovic, P.
    Antic, V.
    [J]. RADIATION PROTECTION DOSIMETRY, 2016, 170 (1-4) : 279 - 283
  • [3] Occupational eye dose in interventional cardiology procedures
    Yoshihiro Haga
    Koichi Chida
    Yuji Kaga
    Masahiro Sota
    Taiichiro Meguro
    Masayuki Zuguchi
    [J]. Scientific Reports, 7
  • [4] Occupational dose constraints in interventional cardiology procedures: the DIMOND approach
    Tsapaki, V
    Kottou, S
    Vano, E
    Komppa, T
    Padovani, R
    Dowling, A
    Molfetas, M
    Neofotistou, V
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (06): : 997 - 1005
  • [5] Occupational hazards of interventional cardiology
    Smilowitz, Nathaniel R.
    Balter, Stephen
    Weisz, Giora
    [J]. CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2013, 14 (04) : 223 - 228
  • [6] Occupational radiation dose and protection to the eye lens for interventional cardiology operators
    Lian, Meng-En
    Wu, Guan-Yi
    Chao, Min-Fang
    Wang, Chong-Sheng
    Miao, Hsiao-Chien
    Tsai, Ming-Sung
    Hsieh, Mu-Yang
    Chen, Yeh-Peng
    Chu, Chun-Yuan
    Chang, Szu-Li
    Tsai, Hui-Yu
    [J]. RADIATION MEASUREMENTS, 2022, 154
  • [7] Interventional cardiology practice
    Tofield, Andros
    [J]. EUROPEAN HEART JOURNAL, 2019, 40 (03) : 234 - 235
  • [8] Occupational Dose Measurement in an Interventional Radiology Facility in Jakarta
    Lubis, L. E.
    Aida, N.
    Pratiwi, N. G.
    Pawiro, S. A.
    Wigati, K. T.
    Soejoko, D. S.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 775 - 777
  • [9] Occupational eye dose correlation with neck dose and patient-related quantities in interventional cardiology procedures
    Ishii, Hiroki
    Chida, Koichi
    Satsurai, Ko
    Haga, Yoshihiro
    Kaga, Yuji
    Abe, Mitsuya
    Inaba, Yohei
    Zuguchi, Masayuki
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2022, 15 (01) : 54 - 62
  • [10] Occupational eye dose correlation with neck dose and patient-related quantities in interventional cardiology procedures
    Hiroki Ishii
    Koichi Chida
    Ko Satsurai
    Yoshihiro Haga
    Yuji Kaga
    Mitsuya Abe
    Yohei Inaba
    Masayuki Zuguchi
    [J]. Radiological Physics and Technology, 2022, 15 : 54 - 62