Occupational eye dose in interventional cardiology procedures

被引:0
|
作者
Yoshihiro Haga
Koichi Chida
Yuji Kaga
Masahiro Sota
Taiichiro Meguro
Masayuki Zuguchi
机构
[1] Tohoku University Graduate School of Medicine,Department of Radiological Technology, Faculty of Health Sciences
[2] Sendai Kousei Hospital,Department of Radiology
[3] International Research Institute of Disaster Science,Department of Radiation Disaster Medicine
[4] Tohoku University,Department of Cardiovascular Medicine
[5] Sendai Kousei Hospital,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
It is important to measure the radiation dose [3-mm dose equivalent, Hp(3)] in the eye. This study was to determine the current occupational radiation eye dose of staff conducting interventional cardiology procedures, using a novel direct eye dosimeter. We measured the occupational eye dose [Hp(3)] in physicians and nurses in a catheterization laboratory for 6-months. The eye doses [Hp(3)] of 12 physicians (9 with Pb glasses, 3 without), and 11 nurses were recorded using a novel direct eye dosimeter, the DOSIRISTM. We placed dosimeters above and under the glasses. We also estimated the eye dose [0.07-mm dose equivalent] using a neck personal dosimeter. The eye doses among interventional staff ranked in the following order: physicians without Pb glasses > physicians with Pb glasses > nurses. The shielding effect of the glasses (0.07-mm Pb) in a clinical setting was approximately 60%. In physicians who do not wear Pb glasses, the eye dose may exceed the new regulatory limit for IR staff. We found good correlations between the neck dosimeter dose and eye dosimeter dose (inside or outside glasses, R2 = 0.93 and R2 = 0.86, respectively) in physicians. We recommend that interventional physicians use an eye dosimeter for correct evaluation of the lens dose.
引用
收藏
相关论文
共 50 条
  • [41] Established interventional procedures in pediatric cardiology
    Freund, M
    [J]. MONATSSCHRIFT KINDERHEILKUNDE, 1998, 146 (05) : 502 - 512
  • [42] Procedural Sedation for Interventional Cardiology Procedures
    Makkad, Benu
    [J]. INTERNATIONAL ANESTHESIOLOGY CLINICS, 2013, 51 (02) : 112 - 126
  • [43] Influence of dosemeter position for the assessment of eye lens dose during interventional cardiology
    Principi, Sara
    Ginjaume, Merce
    Amor Duch, Maria
    Sanchez, Roberto M.
    Fernandez, Jose M.
    Vano, Eliseo
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 164 (1-2) : 79 - 83
  • [44] The current status of eye lens dose measurement in interventional cardiology personnel in Thailand
    Krisanachinda A.
    Srimahachota S.
    Matsubara K.
    [J]. Radiological Physics and Technology, 2017, 10 (2) : 142 - 147
  • [45] Occupational doses to the eye lens in pediatric and adult noncardiac interventional radiology procedures
    Morcillo, Ana Belen
    Alejo, Luis
    Huerga, Carlos
    Bayon, Jose
    Marin, Alberto
    Corredoira, Eva
    Novo, Joan Ricardo
    Hernandez, Teresa
    Ponce, Maria Dolores
    Garzon, Gonzalo
    Vano, Eliseo
    Guibelalde, Eduardo
    [J]. MEDICAL PHYSICS, 2021, 48 (04) : 1956 - 1966
  • [46] Assessment of occupational radiation doses to eye lens during interventional radiology procedures
    Ali, Amir
    Al-Nuaimi, Meshari
    Khan, Banaras
    Burki, Shamsullah
    Nishtar, Tahira
    Yaseen, Muhammad
    Shah, Syed Sher Azam
    Irfan, Muhammad
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2024, 225
  • [47] Eye Lens Dose Reduction of Radiologists in Interventional Procedures with Lead Glasses
    Hu, P.
    Zhuo, W.
    Liu, H.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3719 - 3719
  • [48] Eye protection in interventional procedures
    Schueler, Beth A.
    Fetterly, Kenneth A.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1126):
  • [49] Patient radiation dose during diagnostic and interventional cardiology procedures A study in a tertiary hospital
    Anim-Sampong, Samuel
    Antwi, William Kwadwo
    Adomako, John Bright
    Botwe, Benard Ohene
    Sarkodie, Benjamin Dabo
    Brakohiapa, Edmund K.
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2023, 54 (02) : 298 - 305
  • [50] Eye lens dosimetry in interventional cardiology: results of staff dose measurements and link to patient dose levels
    Antic, V.
    Ciraj-Bjelac, O.
    Rehani, M.
    Aleksandric, S.
    Arandjic, D.
    Ostojic, M.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 154 (03) : 276 - 284