The current status of eye lens dose measurement in interventional cardiology personnel in Thailand

被引:12
|
作者
Krisanachinda A. [1 ]
Srimahachota S. [2 ]
Matsubara K. [3 ]
机构
[1] Department of Radiology, Faculty of Medicine, Chulalongkorn University, Rama IV Road, Bangkok
[2] Department of Medicine, Faculty of Medicine, Chulalongkorn University, Rama IV Road, Bangkok
[3] Department of Quantum Medical Technology, Faculty of Health Sciences, Kanazawa University, Kanazawa, Ishikawa
关键词
Cataract; Effective dose; Eye dosimetry; Interventional cardiology; Lens opacity; Optically stimulated luminescence;
D O I
10.1007/s12194-017-0403-8
中图分类号
学科分类号
摘要
Workers involved in interventional cardiology procedures receive high eye lens doses if radiation protection tools are not properly utilized. Currently, there is no suitable method for routine measurement of eye dose. In Thailand, the eye lens equivalent doses in terms of Hp(3) of the interventional cardiologists, nurses, and radiographers participating in interventional cardiology procedures have been measured at 12 centers since 2015 in the pilot study. The optically stimulated luminescence (OSL) dosimeter was used for measurement of the occupational exposure and the eye lens dose of 42 interventional cardiology personnel at King Chulalongkorn Memorial Hospital as one of the pilot centers. For all personnel, it is recommended that a first In Light OSL badge is placed at waist level and under the lead apron for determination of Hp(10); a second badge is placed at the collar for determination of Hp(0.07) and estimation of Hp(3). Nano Dots OSL dosimeter has been used as an eye lens dosimeter for 16 interventional cardiology personnel, both with and without lead-glass eyewear. The mean effective dose at the body, equivalent dose at the collar, and estimated eye lens dose were 0.801, 5.88, and 5.70 mSv per year, respectively. The mean eye lens dose measured by the Nano Dots dosimeter was 8.059 mSv per year on the left eye and 3.552 mSv per year on the right eye. Two of 16 interventional cardiologists received annual eye lens doses on the left side without lead glass that were higher than 20 mSv per year, the new eye lens dose limit as recommended by ICRP with the risk of eye lens opacity and cataract. © 2017, Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:142 / 147
页数:5
相关论文
共 50 条
  • [1] EYE LENS DOSE IN INTERVENTIONAL CARDIOLOGY
    Principi, S.
    Delgado Soler, C.
    Ginjaume, M.
    Beltran Vilagrasa, M.
    Rovira Escutia, J. J.
    Duch, M. A.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 289 - 293
  • [2] Staff eye lens dose in interventional radiology and cardiology in Finland
    Pekkarinen, Antti
    Lindholm, Carita
    Kortesniemi, Mika
    Siiskonen, Teemu
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 98 : 1 - 7
  • [3] Occupational radiation dose and protection to the eye lens for interventional cardiology operators
    Lian, Meng-En
    Wu, Guan-Yi
    Chao, Min-Fang
    Wang, Chong-Sheng
    Miao, Hsiao-Chien
    Tsai, Ming-Sung
    Hsieh, Mu-Yang
    Chen, Yeh-Peng
    Chu, Chun-Yuan
    Chang, Szu-Li
    Tsai, Hui-Yu
    [J]. RADIATION MEASUREMENTS, 2022, 154
  • [4] Influence of dosemeter position for the assessment of eye lens dose during interventional cardiology
    Principi, Sara
    Ginjaume, Merce
    Amor Duch, Maria
    Sanchez, Roberto M.
    Fernandez, Jose M.
    Vano, Eliseo
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 164 (1-2) : 79 - 83
  • [5] Estimating brain and eye lens dose for the cardiologist in interventional cardiology-are the dose levels of concern?
    Hulthen, Markus
    Tsapaki, Virginia
    Karambatsakidou, Angeliki
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2024, 97 (1158):
  • [6] Assessment of the occupational eye lens dose for clinical staff in interventional radiology, cardiology and neuroradiology
    Omar, Artur
    Kadesjo, Nils
    Palmgren, Charlotta
    Marteinsdottir, Maria
    Segerdahl, Tony
    Fransson, Annette
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2017, 37 (01) : 145 - 159
  • [7] A study of the dose distribution in the region of the eye lens and extremities for staff working in interventional cardiology
    Domienik, J.
    Brodecki, M.
    Rusicka, D.
    [J]. RADIATION MEASUREMENTS, 2012, 47 (02) : 130 - 138
  • [8] Eye lens dosimetry in interventional cardiology: results of staff dose measurements and link to patient dose levels
    Antic, V.
    Ciraj-Bjelac, O.
    Rehani, M.
    Aleksandric, S.
    Arandjic, D.
    Ostojic, M.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 154 (03) : 276 - 284
  • [9] Occupational eye dose in interventional cardiology procedures
    Haga, Yoshihiro
    Chida, Koichi
    Kaga, Yuji
    Sota, Masahiro
    Meguro, Taiichiro
    Zuguchi, Masayuki
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [10] Eye lens dose of medical personnel involved in fluoroscopy and interventional procedures at a Malaysian Hospital
    Wong, Jeannie Hsiu Ding
    Anem, Lydia Esther Andrew
    Tan, Suzet
    Tan, Sock Keow
    Ng, Kwan Hoong
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 68 : 47 - 51